| 2018-01-18 14:43:30 | 1ST REVIEW: FBC 2014 5TH EDITION | | | | | | PLUMBING COMMENTS: | | | | | | 1. THE COVER SHEET IS LISTING THE WRONG FBC IT SHALL BE | | | 2014 5TH EDITION P[LEASE CLARIFY. PER WPB AMEND TO FBC | | | 107.2.1 | | | | | | 2. THE EXISTING DISHWASHING ON A1.0 DOES NOT MATCH AREA | | | ON D1.0 PLEASE CLARIFY. PER WPB AMEND TO FBC 107.2.1 | | | | | | 3. A BACKFLOW DEVISE IS REQUIRED ON THE WATER FILTER | | | AND SODA MACHINE. PER FBC PL 608.3, 608.16.1 | | | | | | 4. SHOW WATER PIPING FOR SODA MACHINE. PER WPB AMEND TO | | | FBC 107.3.5.1.3(13) | | | | | | 5. HAND SINK SHOWN ON D1.0 NEXT TO NEW COFFEE MACHINE | | | LOCATION IS NOT SHOWN ON A1.0 OR P1.0 PLEASE CLARIFY. | | | PER WPB AMEND TO FBC 107.2.1 | | | | | | 6. THE SINK NEXT TO WIC NOT SHOWN ON D1.0 IS THIS A NEW | | | SINK PLEASE CLARIFY. PER WPB AMEND TO FBC 107.2.1 | | | | | | 7. A SEPARATE PERMIT WILL BE REQUIRED FOR ANY GAS WORK | | | CAPPING OF EXISTING APPLIANCES AND INSTALLING NEW ONES. | | | PROVIDE NOTE ON PLAN. PER WPB AMEND TO FBC 107.2.1 | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT | | | CORRECTED PAGES INTO TO SUBMITTAL AND REMOVE OR VOID | | | THE PREVIOUSLY REVIEWED SHEETS. | | | | | | GEORGE JOHNSON | | | PLUMBING PLANS EXAMINER | | | CITY OF WEST PALM BEACH | | | 561-805-6711 | | | [email protected] | | | |
|