Plan Review Notes
Plan Review Notes For Permit 17110874
Permit Number 17110874
Review Stop NFIP
Sequence Number 2
Notes
Date Text
2018-07-14 13:23:37THIS PERMIT WILL BE ISSUED WITH PROVISO:
  
 BUILDING UNDER CONSTRUCTION ELEVATION CERTIFICATE
 REQUIRED PRIOR TO FINISHED FLOOR CONCRETE POUR
 FINISHED CONSTRUCTION ELEVATION CERTIFICATE REQUIRED
 PRIOR TO CO OR TCO
  
 THE FOUNDATION PERMIT, WAS SUBMITTED UNDER THE 1979
 FIRMS. THEREFORE, THE MINIMUM DFE IS 8' NGVD29 (7' BFE
 + 1' FREEBOARD). APPLICANT COMPLIES WITH THE 2017 FIRMS
 + 2' FREEBOARD (APPROX 5.5' NAVD88 PER FIS + 2'
 FREEBOARD=7.5' NAVD88)
  
 THE DFE FOR THIS STRUCTURE IS 9' NGVD29
  
  
  
2018-04-02 08:08:06PROVISOS:
 A) ONCE THE FIRST FLOOR SLAB IS POURED THE 2ND
 ELEVATION CERTIFICATE IS REQUIRED.
 B) BEFORE THE ISSUANCE OF A CERTIFICATE OF OCCUPANCY OR
 A CERTIFICATE OF COMPLETION THE 3RD FLOOD ZONE
 CERTIFICATE IS REQUIRED WITH THE HEIGHT OF ALL EXTERIOR
 ATTENDANTS A/C PADS OR OTHER SLABS FOR GENERATORS.
  