| Date |
Text |
| 2017-12-05 07:27:03 | ****CORRECTIONS**** |
| | REVISED 1/3/18 |
| | |
| | SAMANTHA HILL |
| | BUILDING PLANS EXAMINER |
| | [email protected] |
| | 561-805-6724 |
| | |
| | FBC = FLORIDA BUILDING CODE, 5TH EDITION (2014) |
| | FBC B = FBC BUILDING |
| | FBC EB = FBC EXISTING BUILDING |
| | FBC A = FBC ACCESSIBILITY |
| | FBC EC = FBC ENERGY CONSERVATION |
| | |
| | FROM PREVIOUS LIST: |
| | |
| | 1. OK |
| | |
| | 2. THE ASSEMBY SELECTED HAS A DESIGN PRSSURE LIMITATION |
| | OF -45 WHICH DOES NOT MEET THE REQUIREMENTS FOR ZONES 2 |
| | AND 3 SPECIFIED BY ENGINEER OF RECORD ON PAGE S3, |
| | PROVIDE ENGINEERING FOR ENHANCED FASTENING (BUT ALSO |
| | SEE COMMENT #3). |
| | |
| | 3. BASED ON FBC B 1609 AND ASCE 7-10, DESIGN PRESSURES |
| | OF -37.9, -63.6 ARE REQUIRED FOR ZONES 2, 3 FOR A |
| | BUILDING WITH 15MRH (SUBJECT BUILDING HAS 18.5'MRH). |
| | "NET UPLIFT" DESIGN PRESSURES APPEAR LOW FOR COMPONENTS |
| | AND CLADDING. SEE ENGINEER'S CALCULATIONS, (OUR PAGE |
| | 200 OF 235), APPEARS TO STATE ZONE 1 -39.50, ZONE 2 AND |
| | 3 -66.28 PSF, WHICH ARE CONSISTENT WITH THE "GROSS |
| | UPLIFT PRESSURES" SPECIFIED. |
| | |
| | THE PURPOSE OF PROVIDING "NET UPLIFT" DESIGN PRESSURES |
| | IS NOT CLEAR, AND IT DOES NOT APPEAR TO BE APPLICABLE |
| | FOR COMPONENTS & CLADDING. CONTRACTOR HAS PROPOSED TO |
| | UTILIZE THE HIGHER "GROSS UPLIFT" DESIGN PRESSURES, |
| | WHICH APPEAR ADEQUATE AND ARE CONSISTENT WITH THE TABLE |
| | IN ASCE7-10. |
| | |
| | TO ADDRESS - WHEN RESUBMITTING, CONTRACTOR IS TO |
| | UTILIZE DESIGN PRESSURES OF -39.50 ZONE 1, -66.28 ZONES |
| | 2/3. |
| | |
| | NEW COMMENT: |
| | |
| | 4. PER ZONING INSPECTION, THE CONTRACTOR HAS EXCEEDED |
| | THE SCOPE OF THE DEMOLITION PORTION OF THE RENOVATION |
| | PERMIT (17021163). WALLS WHICH WERE TO REMAIN WERE |
| | REMOVED. CONTRACTOR IS TO SUBMIT A REVISION INCLUDING |
| | THIS WORK IMMEDIATELY. AN INSPECTION HOLD HAS BEEN |
| | PLACED ON THE PARCEL. THIS ROOF PERMIT WILL NOT BE |
| | ISSUED UNTIL THIS HAS BEEN ADDRESSED. APPLICANT MAY |
| | RESUBMIT, BUT ISSUANCE MAY BE DELAYED UNTIL OTHER ISSUE |
| | IS RESOLVED. |
| | |
| | |