Plan Review Notes
Plan Review Notes For Permit 17110860
Permit Number 17110860
Review Stop B
Sequence Number 2
Notes
Date Text
2018-03-08 11:00:122014 FBC- BUILDING PLAN REVIEW
 W. P. B. PERMIT: 17110860
 ADD: 1901 VILLAGE BLVD. / BEAR LAKES COUNTRY CLUB
 CONT: MOUW ASSOCIATES, INC.
 TEL: 561-276-9640
 E-MAIL: [email protected]
  
 2014 FLORIDA BUILDING CODE W 2014 WEST PALM BEACH
 AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1,
 ADMINISTRATION
  
 2014 EXISTING BUILDING CODE. 801.3 COMPLIANCE. ALL NEW
 CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND SPACES
 SHALL COMPLY WITH THE REQUIREMENTS OF THE FLORIDA
 BUILDING CODE, BUILDING.
  
 2ND REVIEW
 DATE: THURS. MARCH 08/2018
 ACTION: DENIED
  
 1) COMPLIED THRESHOLD BUILDING / FL S. S. 553.71(7
  
 2)PROVISO: ART IN PUBLIC PLACES
 THE CITY OF WEST PALM BEACH ART IN PUBLIC PLACES
 ORDINANCE REQUIREMENT THAT APPLIES TO ANY REMODEL OR
 NEW CONSTRUCTION PROJECT FOR WHICH THE PERMIT
 APPLICATION WAS SUBMITTED AFTER 6/29/14, AND THE TOTAL
 PROJECT CONSTRUCTION COSTS ARE EQUAL TO OR GREATER THAN
 $750,000 WILL NEED TO COMPLY WITH THIS ORDINANCE.
 PER CITY OF WEST PALM BEACH ORDINANCE NO. 4504-14, AND
 CITY OF WEST PALM BEACH CODE OF ORDINANCES, ARTICLE V,
 ART IN PUBLIC PLACES, SECTION 78-123(A) AND SECTION
 78-126(A), THE ART ASSESSMENT IS 1% OF THE TOTAL
 PROJECT CONSTRUCTION COST.
 PER CITY OF WEST PALM BEACH CODE OF ORDINANCES, ARTICLE
 V, ART IN PUBLIC PLACES, SECTION 78-122, RENOVATION AND
 NEW CONSTRUCTION PROJECTS ARE ASSESSED CUMULATIVELY, SO
 THE ART ASSESSMENT WILL BE APPLICABLE TO ALL FUTURE
 PROJECTS.
 SEC. 78-129. - PUBLIC ART ASSESSMENT FOR PRIVATE
 DEVELOPMENT.
 (A) APPLICABILITY. THE PROVISIONS OF THIS ARTICLE AND
 THE PUBLIC ART ASSESSMENT SECTION SHALL APPLY TO ALL
 PRIVATE DEVELOPMENT PROJECTS, INCLUDING NEW
 CONSTRUCTION, OR THE RENOVATION OR IMPROVEMENT OF AN
 EXISTING BUILDING, WHERE TOTAL CONSTRUCTION COSTS ARE
 EQUAL TO OR GREATER THAN $750,000.00. ALL BUILDINGS
 WITHIN NEW PLANNED DEVELOPMENTS SHALL BE ASSESSED
 CUMULATIVELY TOWARDS THIS ART IN PUBLIC PLACES
 REQUIREMENT, EVEN IF THE BUILDINGS ARE PERMITTED
 SEPARATELY OR DEVELOPED IN PHASES. THE PROVISIONS OF
 THIS SECTION APPLY TO NEW DEVELOPMENT OR NEW
 CONSTRUCTION WITHIN EXISTING PLANNED DEVELOPMENTS.
 FOR CONTACT INFORMATION PLEASE CONTACT:
 MS. SYBILLE WELTER ART IN PUBLIC PLACES COORDINATOR
 822-1515 E-MAIL: [email protected]
  
 3) COMPLIED.
  
 4) SEMI-COMPLIED. 2ND REVIEW A COPIED SOILS REPORT WAS
 SUBMITTED, BUT THE SIGNATURE AND SEAL ARE COPIED NOT
 ELECTRONICALLY SIGNED AND SEALED, YOU MAY WANT TO
 PROVIDE THE CITY WITH A PAPER ORIGINAL SIGNED AND
 SEALED SOILS REPORT, NOT A PHOTOCOPIED BLUE INK
 SIGNATURE, THEY SHOW AS A PIXILATED SIGNATURE.
 FLORIDA ADMINISTRATIVE CODE 61G15-23.005 (3)(C) A
 SCANNED, FACSIMILE, DIGITALLY CREATED OR COPIED IMAGE
 OF THE LICENSEE?S SIGNATURE SHALL NOT BE USED ON
 ELECTRONICALLY SIGNED AND SEALED ENGINEERING PLANS,
 SPECIFICATIONS, REPORTS OR OTHER DOCUMENTS.
 1ST REVIEW COMMENT. THIS REVIEW THERE WAS NO SOILS
 REPORT SUBMITTED. THE FOUNDATION PLAN 098_S1.2 THE
 FOUNDATION DETAIL # 1 SHOWS THE USE OF HELICAL PILES.
 FOUNDATION NOTE # 6 INDICATES THE HELICAL PILES SHALL
 HAVE A MINIMUM ALLOWABLE COMPRESSION CAPACITY OF 50K
 AND TENSION CAPACITY OF 10 K. THE SOILS REPORT WILL
 PROVIDE AN ANALYSIS OF THE SOILS AND COMPLIANCE WITH
 THE 2014 FBC-B 1810.3.3.1.9. THRESHOLD INSPECTOR TO BE
 ONSITE
 TO VERIFY THE INSTALLATION, INSPECT AND RECORD THE
 RESULTS OF THE HELICAL PILES AND CODE COMPLIANCE.
  
 5-6) COMPLIED.
  
 7) SEMI-COMPLAINED. SEE COMMENTS BELOW. SHEET
 003_G-102. THE CHART SHOWING THE VARIOUS ROOMS AND
 OCCUPANT LOADS THERE ARE QUESTIONS WHY CERTAIN ROOMS
 SHOW ZERO OCCUPANTS.
  
 7A-B) COMPLIED.
  
 7C) 2ND REQUEST. THE LIFE SAFETY ROOM 2063 MEMBERS
 GALLERY, FBC-B TABLE 1004.1.2. ASSEMBLY TABLES AND
 CHAIRS @15 SQ. FT./ OCCUPANT.
  
 7D) 2ND REQUEST. ROOM 2070 GOLF SHOP VESTIBULE, , FBC-B
 TABLE 1004.1.2. ASSEMBLY TABLES AND CHAIRS @15 SQ. FT./
 OCCUPANT.
  
 7E-F) COMPLIED.
  
 8-11) COMPLIED.
  
 12) SEMI-COMPLIED. NEW COMMENT. SHEET 028_A-506. THE
 MENS LOCKER ROOM HAS THE SAME SITUATION,
 SHEET 003.1 G-102 SHOWS AN OCCUPANT LOAD OF 70 PEOPLE
 BUT ONLY ONE MEANS OF EGRESS. THIS AREA WILL ALSO
 REQUIRE A 2ND MEANS OF EGRESS. THE NEW REVISED PLAN
 SHOWS THE 2ND EXIT REMOVED.
  
 1ST REVIEW COMMENTS. SHEET 031_A-603 SHOWS EXIT LIGHTS
 IN BOTH THE MENS AND LADIES LOCKER ROOMS. THE MENS
 LOCKER ROOM IS NOT REQUIRED TO HAVE A SECOND MEANS OF
 EGRESS BUT THE SAME SITUATION AS WITHIN THE LADIES
 LOCKER ROOM, 2014 FBC-B TABLE 1015.1.
 THERE IS A INTERVENING ROOM (2047) WHICH IS ALLOWED
 (1014.2) WITH THE EXCEPTION OF (4).
 4. EGRESS SHALL NOT PASS THROUGH KITCHENS, STORAGE
 ROOMS, CLOSETS OR SPACES USED FOR SIMILAR PURPOSES.
 THE LOCKER ROOMS ARE USED FOR STORAGE.
  
 13A)2ND REQUEST. THE ORIGINAL REQUEST IS TO SHOW THE
 30X48 INCH CLEAR FLOOR SPACE FOR THE SHOWER, IT SHOULD
 COMPLY WITH ACC. CODE 608.2.1 TRANSFER SHOWER
 COMPARTMENTS.
 1ST ROUND COMMENT. . SHEET 028_A-506 IN BOTH THE LADIES
 AND MENS ACCESSIBLE SHOWERS, ROOMS 2060, 2061 & 2075
 THERE IS NO CLEAR FLOOR SPACE SHOWN ON THE FLOOR PLAN.
 PLEASE REVIEW THE 2014 ACCESSIBILITY CODE 608.2.1
 TRANSFER TYPE SHOWER COMPARTMENTS. TRANSFER TYPE SHOWER
 COMPARTMENTS SHALL BE 36 INCHES (915 MM) BY 36 INCHES
 (915 MM) CLEAR INSIDE DIMENSIONS MEASURED AT THE CENTER
 POINTS OF OPPOSING SIDES AND SHALL HAVE A 36 INCH (915
 MM) WIDE MINIMUM ENTRY ON THE FACE OF THE SHOWER
 COMPARTMENT. CLEARANCE OF 36 INCHES WIDE MINIMUM BY 48
 INCHES LONG MINIMUM MEASURED FROM THE CONTROL WALL
 SHALL BE PROVIDED. SHOW THE CONTROLS ON WALL.
  
 13B-D) COMPLIED.
  
 14) 2ND REQUEST. THE FINISH SCHEDULE INDICATES TILE FOR
 THE FLOOR, BASE & WALLS BUT THE SCHEDULE DOES NOT SHOW
 COMPLIANCE WITH THE TILE BACKING.
 1ST ROUND COMMENTS. THE PLAN DOES NOT ADDRESS RESTROOM/
 BATHROOM FINISHES IN WET AREAS, PLEASE SHOW COMPLIANCE
 WITH FBC-B 2509.2 BASE FOR TILE & 2509.3 LIMITATIONS.
  
 15-16) COMPLIED.
  
 17) 2ND REQUEST. THE RESPONSE INDICATED THE STRUCTURAL
 SUPPORTS FOR THE FOLDING DOOR WERE ON SHEET S1.3.
 PLEASE NOTE THERE ARE NO REVISIONS TO SHEET S1.3.
 1ST ROUND OF COMMENTS. PLEASE SUBMIT THE FOLDING DOOR
 MANUFACTURED SPECS OF HOW IT IS TO BE HUNG, AND IF IT
 WOULD TAKE EXTRA SUPPORT NOT SHOWN ON THE STRUCTURAL
 SHEETS. 107.2.1.3. ADDITIONAL INFORMATION IS REQUIRED.
  
 18-19) COMPLIED.
  
 20A) COMPLIED. SEE MECH. COMMENT # 3. 2014 FBC-M 404.1.
  
 20B-C) COMPLIED.
  
  
  
 21)2ND REQUEST. SEMI-COMPLIED. THANK YOU FOR THE
 PRESSURES IN VASD. THE ISSUE IS WITH THE WALL
 PRESSURES. THE NEGATIVE WALL ZONE 5 PRESSURES ARE THE
 SAME AS FOR ZONE 4. IN THE ASCE 7-10 FIGURE 30.4-2B
 UNDER NOTE # 7, THERE IS A NOTE STATING THE ROOF ZONE 3
 WITH HIPS 0<25DEGREES THE ZONE 3 SHALL BE TREATED AS
 ZONE 2. THERE IS NO REDUCTION FOR WALL ZONE 5. PLEASE
 UPDATE BOTH THE VULT AND VASD NEGATIVE WALL PRESSURES
 FOR ZONE 5. FLAT ROOFS WITH PARAPETS GREATER THAN 3
 FEET ALSO GET A ROOF ZONE 3 REDUCTION TO ZONE 2
 PRESSURES.
 1ST ROUND OF SHEET 095_S0.2 PROVIDES THE COMPONENTS AND
 CLADDING PRESSURES IN VULT PRESSURES. PLEASE PROVIDE
 THE PRESSURES ALSO IN VASD SINCE THE PRODUCT APPROVALS
 ARE ALL IN VASD. FBC-B 1609.3.1 WIND SPEED CONVERSION
 VULT TO VASD.
  
 22) BUILDING PROVISO/ DEFERRED SUBMITTALS: PLEASE
 SUBMIT (3) COPIES OF EACH. 2014 FBC-B 1609.1.2
 PROTECTION OF OPENINGS, 1609.6.4.4.1 COMPONENTS &
 CLADDING. FLORIDA DEPARTMENT OF COMMUNITY AFFAIRS,
 ADMINISTRATIVE CODE 61G20-3.005, RULE 9N-3 NOV. 01/
 2010 (31) SUB-CATEGORY OF PRODUCTS OR CONSTRUCTION
 SYSTEMS THAT WILL REQUIRE PRODUCT APPROVALS:
 (31)(A) EXTERIOR DOORS ,MULLIONS & ROOF HATCHES.
 (B) WINDOWS & MULLIONS
 (C) PANEL WALLS: STOREFRONTS, CURTAIN WALLS, WALL
 LOUVERS, EFIS SYSTEMS,
 (D) ROOFING PRODUCTS AND ASSEMBLIES, ROOF TOP
 VENTILATORS
 (G) PRE-ENGINEERED A/C STANDS
  
 23) BUILDING PROVISO/ DEFERRED SUBMITTALS: IDENTIFY
 GLAZING/ MULLIONS. PLEASE IDENTIFY ON THE PRODUCT
 APPROVAL BEFORE SUBMITTING TO DESIGNER OF RECORD AND
 BEFORE SUBMISSION TO THE BUILDING DEPARTMENT. FOR ALL
 PRODUCTS WITH GLAZING, PLEASE IDENTIFY THE OPENING
 WIDTH & HEIGHT, TYPE OF GLAZING, MULLION SIZE, LENGTH
 IF UNREINFORCED OR REINFORCED INFORMATION IF REQUIRED,
 ATTACHMENTS AND ASSOCIATE PRESSURES FOR EACH OPENING
 SIZE. 2014 FBC-B 1405.13.1 INSTALLATION. WINDOWS AND
 DOORS SHALL BE INSTALLED IN ACCORDANCE WITH APPROVED
 MANUFACTURERS INSTRUCTIONS. FASTENER SIZE AND SPACING
 SHALL BE PROVIDED IN SUCH INSTRUCTIONS AND SHALL BE
 CALCULATED BASED ON MAXIMUM LOADS AND SPACING USED IN
 THE TESTS.
  
 24) BUILDING PROVISO/ DEFERRED SUBMITTALS: ROOFING: FOR
 ALL ROOFING PRODUCTS PLEASE IDENTIFY ALL ROOFING
 SUB-SYSTEMS AND THEIR ASSOCIATED PRESSURES FOR ROOF
 ZONE # 1. REVIEW THE PRODUCT APPROVAL LIMITATIONS, IF
 ENHANCED FASTENING IS ALLOWED FOR ROOF ZONES 2 & 3.
 107.2.1.2 FOR ROOF ASSEMBLIES REQUIRED BY THE CODE, THE
 CONSTRUCTION DOCUMENTS SHALL ILLUSTRATE, DESCRIBE AND
 DELINEATE THE TYPE OF ROOFING SYSTEM, MATERIALS,
 FASTENING REQUIREMENTS, FLASHING REQUIREMENTS AND WIND
 RESISTANCE RATING THAT ARE REQUIRED TO BE INSTALLED.
 PRODUCT EVALUATION AND INSTALLATION SHALL INDICATE
 COMPLIANCE WITH THE WIND CRITERIA REQUIRED FOR THE
 SPECIFIC SITE OR A STATEMENT BY AN ARCHITECT OR
 ENGINEER FOR THE SPECIFIC SITE MUST BE SUBMITTED WITH
 THE CONSTRUCTION DOCUMENTS.
  
 25) BUILDING PROVISO/ DEFERRED SUBMITTALS: W. P. B.
 107.3.4.1 PRODUCT APPROVALS. THOSE PRODUCTS WHICH ARE
 REGULATED BY THE DCA RULE 9N-03 SHALL BE REVIEWED AND
 APPROVED IN WRITING BY THE DESIGNER OF RECORD PRIOR TO
 SUBMITTAL FOR JURISDICTIONAL APPROVAL. FL 61G1-23.015
 (2) THE ARCHITECT IS RESPONSIBLE FOR SUPERVISING AND
 REVIEWING ALL PROJECT DATA, REPORTS, SHOP DRAWINGS
 ETC..
  
 26) BUILDING PROVISO: 107.3.4.2 DEFERRED SUBMITTALS.
 FOR THE PURPOSES OF THIS SECTION, DEFERRED SUBMITTALS
 ARE DEFINED AS THOSE PORTIONS OF THE DESIGN THAT ARE
 NOT SUBMITTED AT THE TIME OF THE APPLICATION AND THAT
 ARE TO BE SUBMITTED TO THE BUILDING OFFICIAL WITHIN A
 SPECIFIED PERIOD. DEFERRAL OF ANY SUBMITTAL ITEMS SHALL
 HAVE THE PRIOR APPROVAL OF THE BUILDING OFFICIAL. THE
 REGISTERED DESIGN PROFESSIONAL IN RESPONSIBLE CHARGE
 SHALL LIST THE DEFERRED SUBMITTALS ON THE CONSTRUCTION
 DOCUMENTS FOR REVIEW BY THE BUILDING OFFICIAL.
  
 27) COMPLIED. BUILDING TO BE FULLY ADA ACCESSIBLE.
  
 28) IMPACT FEES. BEFORE A PERMIT TO CONSTRUCT, MAY BE
 ISSUED, IMPACT FEES MUST BE PAID TO PALM BEACH COUNTY.
 ONE SET OF PLANS WILL HAVE TO BE TAKEN (BY THE
 CONTRACTOR OR REPRESENTATIVE) TO THE PALM BEACH COUNTY
 IMPACT FEE OFFICE LOCATED AT 2300 N. JOG RD. ROOMS
 2W01-2W14 WEST PALM BEACH, FL. THE ACTUAL PERMIT SET OF
 PLANS MUST BE STAMPED BY THAT OFFICE, AND A COPY OF THE
 PAID RECEIPT ATTACHED TO THE PERMIT APPLICATION. PLEASE
 CALL (561)233-5025 FOR MORE INFORMATION.
  
 29) CLOSING. WHEN RESUBMITTING PLANS PLEASE INDICATE
 THE REVISION & REMOVE ANY VOIDED SHEETS & REPLACE ANY
 PAGES AS NECESSARY. A TRANSMITTAL LETTER LISTING THE
 ORIGINAL REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF
 THE REVISION MADE, IDENTIFYING THE SHEET OR
 SPECIFICATION PAGE WHERE THE CHANGES CAN BE FOUND WILL
 HELP TO EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR
 ANTICIPATED COOPERATION.
  
 JAMES A. WITMER BN, PX, CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
 CONSTRUCTION SERVICES DIVISION / DEVELOPMENT SERVICES
 DEPARTMENT
 401 CLEMATIS ST.
 WEST PALM BEACH. FL 33402
 TEL: 561-805-6715
 FAX: 561-805-6676
 E-MAIL: [email protected]
  