Plan Review Notes
Plan Review Notes For Permit 17110817
Permit Number 17110817
Review Stop B
Sequence Number 1
Notes
Date Text
2017-11-21 06:52:08****CORRECTIONS****
  
 SAMANTHA HILL
 BUILDING PLANS EXAMINER
 [email protected]
 561-805-6724
  
 FBC = FLORIDA BUILDING CODE, 5TH EDITION (2014)
 FBC B = FBC BUILDING
 FBC EB = FBC EXISTING BUILDING
 FBC A = FBC ACCESSIBILITY
 FBC EC = FBC ENERGY CONSERVATION
  
 1. FBC RESIDENTIAL 301, THIS PARCEL IS LOCATED IN
 EXPOSURE C. BASED ON DESIGN PRESSURES IN FBC
 RESIDENTIAL TABLE 301.2.2(2) AND (3), THE ASSEMBLY
 SELECTED DOES NOT MEET MINIMUM REQUIREMENTS.
  
 EITHER PROVIDE CALCULATIONS TO SHOW HOW PROPOSED DESIGN
 PRESSURES WERE OBTAINED, OR PROVIDE ENGINEERING FOR
 ENHANCED FASTENING FOR ZONES 2&3, OR SELECT A DIFFERENT
 ASSEMBLY, OR OTHERWISE ADDRESS.
  
 SEE NOTE 5.7 ON PAGE 4 OF 4, PRODUCT APPROVAL.
  
  
  


Account Summary | Usage Policy | Privacy Policy