| 2018-03-09 11:24:16 | ****PLAN REVIEW COMMENTS**** |
| | |
| | ART LANGE BUILDING PLANS EXAMINER |
| | |
| | DEVELOPMENT SERVICES DEPARTMENT |
| | BUILDING DIVISION |
| | 401 CLEMATIS STREET |
| | WEST PALM BEACH, FL 33402 |
| | 561-805-6718 [email protected] |
| | |
| | FBC FLORIDA BUILDING CODE 2014 5TH EDITION W/2010 WEST |
| | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, |
| | CHAPTER 1 ADMINISTRATION |
| | AZOLA WEST PALM BEACH 17110787 LEASING CENTER |
| | |
| | SECOND REVIEW: |
| | |
| | 1. ELEVATION CERTIFICATE NOT PROVIDED. |
| | |
| | FLOOD ZONE CERTIFICATES |
| | FBC 1612 AND CITY OF WPB CODE OF ORDINANCES SECTION |
| | 94-546. STRUCTURE IS LOCATED IN AN "A" FLOOD ZONE. |
| | AFTER OCTOBER 11, 2017 AN ADDITIONAL ONE FOOT OF FREE |
| | BOARD WILL BE REQUIRED OR (2) FREE BOARD, DESIGN FLOOD |
| | ELEVATION. |
| | NOTE: EFFECTIVE OCTOBER 5, 2017 THE FLOOD ZONE MAPS |
| | HAVE BEEN REVISED. PLEASE UPDATE THE SURVEY AND CIVIL |
| | DRAWINGS TO REFLECT THE NEW FLOOD ZONE AND COMPLIANCE |
| | WITH NAV 88. |
| | FLOOD ELEVATION CERTIFICATE WILL BE REQUIRED. |
| | DURING THE PERMITTING OF THIS STRUCTURE THERE WILL BE |
| | REQUIRED (3) DIFFERENT FLOOD ZONE CERTIFICATES |
| | REQUIRED: |
| | (A) A FLOOD ZONE CERTIFICATE IS REQUIRED AS PART OF THE |
| | PLAN REVIEW DOCUMENTS WITH THE PROPOSED FINISH FLOOR |
| | HEIGHT. |
| | (B) ONCE THE FIRST FLOOR SLAB IS POURED THE 2ND |
| | ELEVATION CERTIFICATE IS REQUIRED |
| | (C) BEFORE THE ISSUANCE OF A CERTIFICATE OF OCCUPANCY |
| | OR A CERTIFICATE OF COMPLETION THE 3RD FLOOD ZONE |
| | CERTIFICATE IS REQUIRED WITH THE HEIGHT OF ALL EXTERIOR |
| | ATTENDANTS, A/C PADS OR OTHER SLABS FOR GENERATORS. |
| | |
| | |
| | 2. OK ADDRESSED |
| | |
| | 3. OK WILL BE PROCESSED AS A DEFERRED SUBMITTAL. |
| | |
| | 4. OK ADDRESSED |
| | 5. OK ADDRESSED |
| | 6. OK ADDRESSED |
| | |
| | 7. OK ADDRESSED |
| | |
| | 8. OK ADDRESSED |
| | |
| | 9. OK ADDRESSED |
| | 10. OK ADDRESSED |
| | |
| | |
| | WHEN RESUBMITTING, PLEASE COMPLETE A RESUBMITTAL FORM: |
| | |
| | HTTP://WPB.ORG/DEVELOPMENT/WP-CONTENT/UPLOADS/SITES/33/ |
| | 2013/09/APPLICATION_RESUBMITTAL_FORM_04132010.PDF |
| | |
| | THIS FORM IS ALSO AVAILABLE AT THE BUILDING DIVISION. |
| | |
| | WHEN RESUBMITTING, SWAP OUT SHEETS WHICH HAVE CHANGED |
| | SO THAT THERE ARE TWO COMPLETE, COLLATED SETS OF PLANS |
| | READY FOR PERMIT ISSUANCE. OLD SHEETS ARE TO BE |
| | RETAINED IN THE PERMIT APPLICATION PACKAGE (SEPARATE |
| | FROM THE PERMIT SETS) AND MARKED *OLD SHEETS* OR |
| | *VOID*. PLEASE KEEP BOTH SETS OF OLD VOIDED SHEETS IN |
| | THE PERMIT PACKAGE. |
| | |
| | A RESPONSE LETTER INDICATING HOW EACH ITEM WAS |
| | ADDRESSED WILL HELP TO EXPEDITE PLAN REVIEW. |
| | |