2017-11-21 08:10:50****CORRECTIONS****
  
 SAMANTHA HILL
 BUILDING PLANS EXAMINER
 [email protected]
 561-805-6724
  
 FBC = FLORIDA BUILDING CODE, 5TH EDITION (2014)
 FBC B = FBC BUILDING
 FBC EB = FBC EXISTING BUILDING
 FBC A = FBC ACCESSIBILITY
 FBC EC = FBC ENERGY CONSERVATION
  
 1. REMOVAL OF EXTERIOR COMPONENTS AND CLADDING VIA A
 DEMO PERMIT IS NOT PERMITTED. TO RESOLVE THIS COMMENT.
 REVISE DEMO PLAN TO REMOVE DEMOLITION OF EXTERIOR
 COMPONENTS FROM THE PLAN.
  
 OR, APPLICANT MAY APPLY FOR A SEPARATE PERMIT WHICH
 INCLUDES REMOVAL AND REPLACEMENT OF THE EXTERIOR
 COMPONENTS, OR REVISE THIS DEMO PERMIT TO AN ALTERATION
 PERMIT, SCOPE TO INCLUDE INTERIOR DEMO AND REMOVAL /
 REPLACEMENT OF WINDOWS/DOORS.
  
 2. SCOPE NOT CLEAR. APPLICATION IS FOR "EARLY START
 PERMIT (DEMOLITION)". VARIOUS NOTES APPEAR TO PROPOSE
 ELECTRICAL WORK (NEW LED STRIP..., NEW LIGHT WALL
 SCONCE, ETC.). AN INTERIOR DEMO PERMIT CANNOT SPECIFY
 RENOVATION WORK. REVISE PLAN TO REMOVE PROPOSED
 ALTERATION WORK OR REVISE SCOPE ON PERMIT TO INTERIOR
 DEMO AND ALTERATION.
  
 THIS APPLICATION WILL NOT BE SENT FOR ELECTRICAL REVIEW
 UNTIL SCOPE OF ELECTRICAL WORK IS CLEAR. IF ANY
 ELECTRICAL DEMOLITION IS PROPOSED, REVISE PLAN TO
 DESCRIBE.
  
 3. PER ANA MARIA APONTE, IF SCOPE OF WORK INCLUDES
 EXTERIOR WORK, ZONING REVIEW IS REQUIRED. A ZONING
 REVIEW WILL NOT BE DONE THIS REVIEW CYCLE PENDING
 CLARIFICATION OF PROPOSED WORK.
  
  
  
  