| Plan Review Notes For Permit 17110686 |
| Permit Number |
17110686 |
|
| Review Stop |
P |
| Sequence Number |
1 |
|
| Notes |
| Date |
Text |
| 2017-12-04 06:29:13 | 12-04-2017 1ST PLUMBING REVIEW**DENIED** | | | | | | 1) KITCHEN SINK SHALL NOT DISCHARGE INTO THE HORIZONTAL | | | WET VENT OF THE BATHROOM GROUP. FPC 912.1 | | | | | | 2) SUPPLY MANUFACTURE SPECS AND INSTALLATION MANUAL FOR | | | TANKLESS WATER HEATER. PLEASE BE ADVISED WATER HEATER | | | MUST BE SIZED SO THAT ALL FIXTURES AT FULL DEMAND HAVE | | | HOT WATER OF (110) FPC604.1 AND FPC 607.1 | | | | | | 3) PLEASE SEE ZONING COMMENT FROM PLAN REVIEW PERMIT# | | | 08090338 DATED 02/12/2008, KITCHEN SINK SHALL NOT BE | | | PERMITTED | | | | | | TIM HUNT | | | PLUMBING INSPECTOR / PLUMBING PLAN REVIEWER | | | CITY OF WEST PALM BEACH DEVELOPMENT SERVICES DEPARTMENT | | | BUILDING DIVISION | | | 561-805-6695 | | | [email protected] | | | | | | |
|