| 2017-12-13 15:28:58 | BUILDING PLAN REVIEW |
| | 2014 FLORIDA BUILDING CODE W/2010 WEST PALM BEACH |
| | AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1 |
| | ADMINISTRATION |
| | |
| | CHRISTOPHER S. THROOP, C.B.O. |
| | PLANS EXAMINER, PX3169 |
| | CONSTRUCTION SERVICES DIVISION |
| | TEL: 561-805-6726 |
| | FAX: 561-805-6676 |
| | |
| | 1ST REVIEW |
| | RESULTS: DENIED |
| | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT |
| | |
| | 1. OWNER/AGENT TO SIGN ENERGY SUBMITTAL FOR MAIN HOUSE. |
| | 2. REVISIT YOUR WINDOW AND DOOR SCHEDULES AND NOA |
| | SUBMITTAL PACKAGE. THERE ARE NOA'S MISSING FROM |
| | SCHEDULES AND NOA'S MISSING FORM SUBMITTAL. I.E. FIXED |
| | WINDOWS/OHD/ETC. |
| | 3. PROVIDE PRODUCT APPROVALS FOR PROPOSED SURFACE MOUNT |
| | WIND ABATEMENT SYSTEM. |
| | 4. PROVIDE ICC-ES REPORT FOR PROPOSED ICYNENE |
| | INSULATION. IDENTIFY PRODUCT TO BE INSTALLED BASED ON |
| | REQUIRED R - VALUE. PRODUCT MANUFACTURERS INSTALLATION |
| | INSTRUCTIONS TO BE ON-SITE AT TIME OF INSPECTION. |
| | 5. REF. PLAN PAGE A101 - WIND EXPOSURE AND SURFACE |
| | ROUGHNESS CATEGORIES SHOULD BE ROUGHNESS B PER FBC |
| | R301.2.1.4.2 & EXPOSURE B PER R301.2.1.4.3. |
| | |
| | FBCE-R101.5.1.1 BUILDING THERMAL ENVELOPE ALTERNATIVE. |
| | AN ACCURATELY COMPLETED RESIDENTIAL BUILDING FORM R402 |
| | SHALL BE SUBMITTED TO THE BUILDING OFFICIAL TO |
| | DEMONSTRATE CODE COMPLIANCE BY THIS METHOD. |
| | |
| | _ OR _ |
| | |
| | FBCE-101.5.1.1.2 SIMULATED PERFORMANCE ALTERNATIVE. |
| | AN ACCURATELY COMPLETED RESIDENTIAL BUILDING FORM R405 |
| | (GENERATED BY COMMISSION APPROVED SOFTWARE) SHALL BE |
| | SUBMITTED TO THE BUILDING OFFICIAL TO DEMONSTRATE CODE |
| | COMPLIANCE BY SECTION 405. |
| | |
| | FBC 107.3.4 - PROVIDE PRODUCT APPROVALS FOR THOSE |
| | PRODUCTS WHICH ARE REGULATED BY FAC RULE 9N-3 REVIEWED |
| | AND APPROVED IN WRITING BY THE DESIGNER OF RECORD. |
| | SPECIFICALLY, PROVIDE ROOFING, WINDOW, AND DOOR |
| | SUBMITTALS. |
| | |
| | R301.2.1.4.2 SURFACE ROUGHNESS CATEGORIES. |
| | A GROUND SURFACE ROUGHNESS WITHIN EACH 45-DEGREE (0.79 |
| | RAD) SECTOR SHALL BE DETERMINED FOR A DISTANCE UPWIND |
| | OF THE SITE AS DEFINED IN SECTION R301.2.1.4.3 FROM THE |
| | CATEGORIES DEFINED BELOW, FOR THE PURPOSE OF ASSIGNING |
| | AN EXPOSURE CATEGORY AS DEFINED IN SECTION |
| | R301.2.1.4.3. |
| | |
| | SURFACE ROUGHNESS B. URBAN AND SUBURBAN AREAS, WOODED |
| | AREAS OR OTHER TERRAIN WITH NUMEROUS CLOSELY SPACED |
| | OBSTRUCTIONS HAVING THE SIZE OF SINGLE-FAMILY DWELLINGS |
| | OR LARGER |
| | |
| | R301.2.1.4.3 EXPOSURE CATEGORIES. |
| | AN EXPOSURE CATEGORY SHALL BE DETERMINED IN ACCORDANCE |
| | WITH THE FOLLOWING: |
| | |
| | EXPOSURE B. FOR BUILDINGS WITH A MEAN ROOF HEIGHT OF |
| | LESS THAN OR EQUAL TO 30 FEET (9144 MM), EXPOSURE B |
| | SHALL APPLY WHERE THE GROUND SURFACE ROUGHNESS, AS |
| | DEFINED BY SURFACE ROUGHNESS B, PREVAILS IN THE UPWIND |
| | DIRECTION FOR A DISTANCE OF AT LEAST 1,500 FEET (457 |
| | M). FOR BUILDINGS WITH A MEAN ROOF HEIGHT GREATER THAN |
| | 30 FEET (9144 MM), EXPOSURE B SHALL APPLY WHERE SURFACE |
| | ROUGHNESS B PREVAILS IN THE UPWIND DIRECTION FOR A |
| | DISTANCE OF AT LEAST 2,600 FEET (792 M) OR 20 TIMES THE |
| | HEIGHT OF THE BUILDING, WHICHEVER IS GREATER. |
| | |
| | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED |
| | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. |
| | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE |
| | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY |
| | RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT |
| | CORRECTED PAGES INTO SUBMITTAL AND LEAVE THE PREVIOUSLY |
| | REVIEWED SHEETS DETACHED AND MARK VOID. |
| | |
| | |
| | |