Plan Review Notes
Plan Review Notes For Permit 17110392
Permit Number 17110392
Review Stop B
Sequence Number 1
Notes
Date Text
2017-11-27 15:49:18****CORRECTIONS****
  
 SAMANTHA HILL
 BUILDING PLANS EXAMINER
 [email protected]
 561-805-6724
  
 FBC = FLORIDA BUILDING CODE, 5TH EDITION (2014)
 FBC B = FBC BUILDING
 FBC EB = FBC EXISTING BUILDING
 FBC A = FBC ACCESSIBILITY
 FBC EC = FBC ENERGY CONSERVATION
  
 1. ALL ITEMS OTHER THAN BUILDING, ROOFING, MECHANICAL,
 ELECTRICAL, PLUMBING REQUIRE SEPARATE PERMITS AND
 SEPARATE FEES, FBC 107. PLEASE SUBMIT A PERMIT
 APPLICATION AND THE SAME NUMBER WILL BE USED FOR THE
 PERMIT.
  
 2. THE FLAGPOLE IS CONSIDERED A STRUCTURE WHICH IS
 REQUIRED TO RESIST WIND LOADS. PROVIDE AN ENGINEERED
 DETAIL, INCLUDING WIND DESIGN CRITERIA, FLORIDA STATUTE
 471. THE SOILS REPORT FOR THIS PARCEL SHOULD BE
 REVIEWED BY DESIGNER OF FLAGPOLE PRIOR TO DESIGN;
 INDICATE REVIEW ON ENGINEERING (OR IN A SEPARATE REVIEW
 LETTER).
  
 3. SEE THE SHOP DRAWING FOR THE FLAGPOLE, FOUNDATION IS
 EXCLUDED FROM THE DESIGN. PLEASE INCLUDE FOUNDATION
 DESIGN IN THE FLAGPOLE ENGINEERING.
  
 4. THERE ARE A NUMBER OF REDLINES ON THE SHOP DRAWINGS.
 INCORPORATE INTO THE ENGINEERING, FS 471. FOR INSTANCE,
 FLAGPOLE WAS DESIGNED FOR A SPECIFIED SIZE OF FLAG;
 THIS AFFECTS RESISTANCE TO WIND LOADS AND THEREFORE
 CANNOT BE DONE WITH REDLINES BUT SHOULD BE INCORPORATED
 INTO THE ENGINEERING.
  
  