| 2018-10-01 11:24:54 | RESIDENTIAL (R3) ADDITION, SECOND BUILDING REVIEW |
| | CHECKLIST. |
| | CODE: FBC 5TH EDITION (2014). |
| | |
| | 1- IMPACT FEES - PAPER SUBMITTALS |
| | |
| | PLANS REQUIRE REVIEW BY THE PBC IMPACT FEE OFFICE. CALL |
| | (561) 233-5025. UPON APPROVAL, YOU MAY CHECK OUT ONE |
| | PLAN SET AND TAKE TO THAT OFFICE FOR REVIEW. PLEASE |
| | RETURNED STAMPED AND WITH A COPY OF THE RECEIPT AS |
| | APPLICABLE. PLEASE PROVIDE THE MUNICIPAL IMPACT FEE |
| | QUESTIONNAIRE FORM TO THE PBC IMPACT FEE OFFICE. THE |
| | FORM CAN BE FOUND AT: HTTP://DISCOVER.PBCGOV.ORG/PZB/AD |
| | MINISTRATION/PDF/IMPACTFEES/FORMS/QUESTIONNAIRE.PDF |
| | |
| | |
| | 2- PROVIDE ENERGY CALCULATIONS (2 COPIES) AS REQUIRED |
| | BY SEC. R101.4.3 FBC-ENERGY CONSERVATION, 5TH EDITION |
| | (2014). |
| | |
| | RESPONSE: |
| | REPEAT COMMENT. NOT ADDRESSED. |
| | |
| | 3- ARCHITECT TO PROVIDE PARTIAL PLAN SHOWING THE ROOMS |
| | ADJACENT TO THE PROPOSED ADDITION AND SHOW COMPLIANCE |
| | WITH THE BEDROOM EGRESS REQUIREMENTS OF SEC. 704 |
| | FBC-EXISTING BUILDING, 5TH EDITION (2014). CLEARLY |
| | IDENTIFY EACH ROOM ON THE FLOOR PLAN. |
| | NOTE: BASED ON CITY RECORDS, IT LOOKS LIKE THERE MAY BE |
| | NO EGRESS WINDOWS FOR EXISTING BEDROOM LOCATED ON THE |
| | NORTH EAST CORNER. |
| | |
| | RESPONSE: |
| | NEW WINDOW #5 (3'-2" BY 4'-6" SINGLE HUNG) FOR EXISTING |
| | BEDROOM #2 DOESN'T COMPLY WITH THE MIN. 24" CLEAR |
| | OPENING HEIGHT REQUIRED BY SEC. R310.1.2 |
| | FBC-RESIDENTIAL. REVISE AS REQUIRED. |
| | |
| | 4- PROPOSED WINDOWS FOR NEW BEDROOMS #1 AND #2 DON'T |
| | SEEM TO COMPLY WITH THE EGRESS REQUIREMENTS OF SEC. |
| | R310.1.2 FBC-RESIDENTIAL. IT LOOKS LIKE THE PROPOSED |
| | WINDOW DON'T HAVE THE 24" CLEAR HEIGHT. REVISE AS |
| | REQUIRED SHOWING COMPLIANCE AND PROVIDE MANUFACTURER'S |
| | SPECS SHOWING THE MIN. CLEAR DIMENSIONS. |
| | |
| | RESPONSE: |
| | FLOOR PLAN WAS REVISED. WINDOW #1 (6'-2" X 4'-6" DOUBLE |
| | SINGLE HUNG) FOR NEW SECOND MASTER BEDROOM DOESN'T |
| | COMPLY WITH THE MIN 24" CLEAR OPENING HEIGHT. REVISE AS |
| | REQUIRED. SEC. R310.1.2 FBC-RESIDENTIAL. |
| | |
| | 5- OK. |
| | |
| | 6- OK. |
| | |
| | 7- SHEET A.3: |
| | A) OK. |
| | |
| | B) OK. |
| | |
| | 8- VALUE DECLARED IN THE PERMIT APPLICATION IS TOO LOW. |
| | VALUE TO INCLUDE ALL THE LABOR, MATERIALS AND |
| | CONTRACTOR'S OVERHEAD AND PROFIT (EVEN FOR |
| | OWNER/BUILDERS) AND ALL DESIGN PROFESSIONAL FEES AS |
| | REQUIRED BY SEC. 109.3 CITY AMENDMENTS. VALUATION FOR |
| | REVISED PLANS WAS UPDATED TO $58,291. THE PERMIT FEE |
| | BALANCE IS $1539.61. |
| | |
| | 9- PROVIDE PRODUCT APPROVAL (2 COPIES) AS REQUIRED BY |
| | FAC 61G20-3.001 FOR: |
| | (NOTE: THIS MAY BE SUBMITTED LATER AS DEFERRED |
| | SUBMITTAL) |
| | |
| | A) ALL WINDOWS AS SPECIFIED ON PLANS. |
| | |
| | B) EXTERIOR DOOR AS SPECIFIED ON PLANS. |
| | |
| | C) ROOF SHINGLES AS SPECIFIED ON PLANS. |
| | |
| | D) WINDOW MULLIONS AS SHOWN ON PLANS. NOTE: CLEARLY |
| | SPECIFY AND MARK MULLION SIZE TO BE INSTALLED TO VERIFY |
| | COMPLIANCE WITH THE CALCULATED DESIGN PRESSURES. |
| | |
| | E) ALL SIMPSON STRUCTURAL CONNECTORS SPECIFIED ON |
| | PLANS. PROVIDE ONLY THE FLORIDA PRODUCT APPROVAL COVER |
| | PAGE AND PAGE SHOWING THE SPECIFIED CONNECTOR OR |
| | ARCHITECT TO LIST THE FLORIDA PRODUCT APPROVAL NEXT TO |
| | EACH SPECIFIED CONNECTOR. |
| | |
| | F) HURRICANE SHUTTERS IF WINDOWS AND DOORS WITH GLAZING |
| | DON'T HAVE IMPACT GLASS. NOTE: AND PROVIDE COMPLETE |
| | HURRICANE SHUTTERS INSTALLATION SCHEDULE. SEE CITY |
| | SAMPLE. |
| | |
| | 10- DESIGNER OF RECORD TO REVIEW AND APPROVE IN WRITING |
| | (NOT SIGNING AND SEALING) ALL PRODUCT APPROVALS AS |
| | REQUIRED BY SEC. 107.3.4.1 CITY AMENDMENTS. |
| | |
| | NEW COMMENT: |
| | 11- REVISED PLANS NOW REFERENCE THE 2017 FBC. PERMIT |
| | APPLICATION AND PLANS WERE REVIEWED UNDER THE 2014 FBC. |
| | REVISE AS REQUIRED. CHAPTER 553 FLORIDA STATUTE. |
| | |
| | |
| | ****PLEASE PROVIDE RESPONSE LETTER ADDRESSING EACH |
| | COMMENT TO HELP EXPEDITE THE REVIEW PROCESS. |
| | ****PLEASE INSERT ANY REVISED DRAWING AND REMOVE OLD |
| | DRAWING. DON'T STAPLE OLD DRAWINGS. SUBMIT OLD DRAWINGS |
| | FOR REFERENCE TO HELP EXPEDITE THE REVIEW PROCESS. |
| | |