| Date |
Text |
| 2017-11-18 07:14:05 | 2014 FBC- BUILDING PLAN REVIEW |
| | W. P. B. PERMIT: 17110283 |
| | ADD: 777 S. FLAGLER DR. SUITE 132 WEST |
| | CONT: CONSTRUCTION SOLUTIONS |
| | TEL: 561-337-7793 |
| | E-MAIL: [email protected] |
| | |
| | 2014 FLORIDA BUILDING CODE W 2014 WEST PALM BEACH |
| | AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1, |
| | ADMINISTRATION |
| | |
| | 2014 EXISTING BUILDING CODE. 801.3 COMPLIANCE. ALL NEW |
| | CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND SPACES |
| | SHALL COMPLY WITH THE REQUIREMENTS OF THE FLORIDA |
| | BUILDING CODE, BUILDING. |
| | |
| | 1ST REVIEW |
| | DATE: SAT. NOV. 18/ 2017 |
| | ACTION: DENIED |
| | |
| | 1) SHEET 100-A0.0 HEADING GOVERNING CODES: |
| | |
| | 1A) BUILDING CONSTRUCTION TYPE IS LISTED AS III-B |
| | SPRINKLERED. PLEASE NOTE THIS IS A 13 STORY HIGH RISE |
| | BUILDING. THE BUILDING CONSTRUCTION TYPE WOULD BE TYPE |
| | I-A. 2014 FBC-B TABLE 503. |
| | |
| | 2) SHEET 130-A1.2 THE LIFE SAFETY PLAN DOES NOT SHOW |
| | THE SWING OF THE MAIN ENTRY DOORS. THE COVERSHEET LIST |
| | OVER 50 OCCUPANTS THE DOORS SHOULD SWING OUT PER |
| | SECTION 1008.1.2 DOOR SWING. DOORS SHALL SWING IN THE |
| | DIRECTION OF EGRESS TRAVEL WHERE SERVING A ROOM OR AREA |
| | CONTAINING AN OCCUPANT LOAD OF 50 OR MORE PERSONS. |
| | |
| | 3A) THE COVERSHEET SHOWS AN OCCUPANT LOAD OF 61 |
| | OCCUPANTS AND THE LIFE SAFETY PLAN SHEET 130-A1.2 SHOWS |
| | 3 EXITS FROM THE TENANT SPACE, THE ONLY ISSUE IS 2 OF |
| | THE 3 EXITS ARE IN KITCHEN / DISH ROOM AREAS LEAVING |
| | ONLY ONE EXIT FOR THE GENERAL PUBLIC TO EXIT BY. WITH |
| | AN OCCUPANT LOAD GREATER THAN 49 THEN 2 EXITS FOR THAT |
| | SPACE ARE REQUIRED. SEE 2014 FBC-B TABLE 1015.1. |
| | |
| | 3B) WITH A FIRE SPRINKLERED BUILDING THE 2 REQUIRED |
| | EXITS OR EXIT ACCESS DOORWAYS WOULD NEED TO BE A |
| | SEPARATION DISTANCE OF THE EXIT DOORS OR EXIT ACCESS |
| | DOORWAYS SHALL NOT BE LESS THAN ONE-THIRD OF THE LENGTH |
| | OF THE MAXIMUM OVERALL DIAGONAL DIMENSION OF THE AREA |
| | SERVED. |
| | |
| | 4) PLEASE NOTE ON SHEETS 110-A1.0 & 130-A1.2 THE LIFE |
| | SAFETY PLAN, BOTH PLANS SHOW ONLY ONE ACCESSIBLE SPACE |
| | AT A TABLE. PLEASE REFER TO THE 2014 FBC-ACCESSIBILITY |
| | CODE SECTION 226.1. WHERE DINING SURFACES ARE PROVIDED |
| | FOR THE CONSUMPTION OF FOOD OR DRINK, AT LEAST 5 |
| | PERCENT OF THE SEATING SPACES AND STANDING SPACES AT |
| | THE DINING SURFACES SHALL COMPLY WITH 902. 50X 0.05%= |
| | 2.5 REQUIRED TO ROUND UP TO 3 SEATS. |
| | |
| | 5) PLEASE SHOW THE ACCESSIBLE SEATS DISPERSED |
| | THROUGHOUT ALL CATEGORIES OF SEATING INCLUDING THE BAR |
| | AREA. 2014 FBC-ACCESS. CODE SECTION 226.2 DISPERSION. |
| | DINING SURFACES AND WORK SURFACES REQUIRED TO COMPLY |
| | WITH 902 SHALL BE DISPERSED THROUGHOUT THE SPACE OR |
| | FACILITY CONTAINING DINING SURFACES AND WORK SURFACES. |
| | |
| | 6) SHOW COMPLIANCE WITH THE 2014 FBC-ACCESSIBILITY CODE |
| | SECTION 902.1 .DINING SURFACES SHALL COMPLY WITH 902.2 |
| | AND 902.3. ADVISORY 902.1 GENERAL. DINING SURFACES |
| | INCLUDE, BUT ARE NOT LIMITED TO, BARS, TABLES, LUNCH |
| | COUNTERS, AND BOOTHS. |
| | |
| | 6)(A) 902.2 CLEAR FLOOR OR GROUND SPACE. A CLEAR FLOOR |
| | SPACE COMPLYING WITH 305 POSITIONED FOR A FORWARD |
| | APPROACH SHALL BE PROVIDED. KNEE AND TOE CLEARANCE |
| | COMPLYING WITH 306 SHALL BE PROVIDED. |
| | |
| | 6)(B) 902.3 HEIGHT. THE TOPS OF DINING SURFACES AND |
| | WORK SURFACES SHALL BE 28 INCHES MINIMUM AND 34 INCHES |
| | MAXIMUM ABOVE THE FINISH FLOOR OR GROUND. |
| | |
| | 7A) SHEET 110-A1.0 IN THE UPPER LEFT HAND CORNER OF THE |
| | SHEET THERE IS A DOOR SCHEDULE AND DOOR D1 IN THE NOTES |
| | INDICATES SEE FLOOR PLAN A1.0. NEITHER DOOR IS |
| | IDENTIFIED ON THIS SHEET. D1 IS LABELED A 2 FOOT 10 |
| | INCH DOOR. SEE SIZE OF DOORS IN THE 2014 FBC-B |
| | 1008.1.1. THE MINIMUM WIDTH OF EACH DOOR OPENING SHALL |
| | BE SUFFICIENT FOR THE OCCUPANT LOAD THEREOF AND SHALL |
| | PROVIDE A CLEAR WIDTH OF 32 INCHES (813 MM). CLEAR |
| | OPENINGS OF DOORWAYS WITH SWINGING DOORS SHALL BE |
| | MEASURED BETWEEN THE FACE OF THE DOOR AND THE STOP, |
| | WITH THE DOOR OPEN 90 DEGREES (1.57 RAD). |
| | |
| | 7B) UNKNOWN LOCATION FOR DOOR D14, SIZE 1 FOOT 91/2 |
| | INCHES WIDE? 107.2.1.3 ADDITIONAL INFORMATION IS |
| | REQUIRED. |
| | |
| | 8) IMPACT FEES. BEFORE A PERMIT TO CONSTRUCT, MAY BE |
| | ISSUED, IMPACT FEES MUST BE PAID TO PALM BEACH COUNTY. |
| | THE ACTUAL PERMIT SET OF PLANS MUST BE STAMPED BY THAT |
| | OFFICE, AND A COPY OF THE PAID RECEIPT ATTACHED TO THE |
| | PERMIT APPLICATION. PLEASE CALL (561)233-5025 FOR MORE |
| | INFORMATION. |
| | |
| | 9) WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION |
| | & REMOVE ANY VOIDED SHEETS & REPLACE ANY PAGES AS |
| | NECESSARY, COLLATE AND STAPLE INTO SETS OF PLANS. A |
| | TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW COMMENT |
| | NUMBER, WITH A DESCRIPTION OF THE REVISION MADE, |
| | IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE THE |
| | CHANGES CAN BE FOUND WILL HELP TO EXPEDITE YOUR PERMIT. |
| | THANK YOU FOR YOUR ANTICIPATED COOPERATION. |
| | |
| | JAMES A. WITMER BN, PX, CBO |
| | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER |
| | CONSTRUCTION SERVICES DIVISION / DEVELOPMENT SERVICES |
| | DEPARTMENT |
| | 401 CLEMATIS ST. |
| | WEST PALM BEACH. FL 33402 |
| | TEL: 561-805-6715 |
| | FAX: 561-805-6676 |
| | E-MAIL: [email protected] |
| | |
| | |
| | |
| | |