| Date |
Text |
| 2017-12-08 07:23:28 | ****CORRECTIONS**** |
| | |
| | SAMANTHA HILL |
| | BUILDING PLANS EXAMINER |
| | [email protected] |
| | 561-805-6724 |
| | |
| | FBC = FLORIDA BUILDING CODE, 5TH EDITION (2014) |
| | FBC B = FBC BUILDING |
| | FBC EB = FBC EXISTING BUILDING |
| | FBC A = FBC ACCESSIBILITY |
| | FBC EC = FBC ENERGY CONSERVATION |
| | |
| | ARCHICTECTURAL SHEETS - KEITH SPINA, GLIDDEN SPINA + |
| | PARTNERS: DIGITAL SEAL/SIGNATURE AND TITLE BLOCK COMPLY |
| | WITH FS481, BUT NEW SHEETS SUBMITTED 2ND CYCLE NEED |
| | REVIEW |
| | |
| | CIVIL SHEETS - GREGORY F. BOLEN, PE, SIMMONS & WHITE, |
| | INC.: DIGITAL SEAL/SIGNATURE AND TITLE BLOCK COMPLY |
| | WITH FS481, BUT NEW SHEETS SUBMITTED 2ND CYCLE NEED |
| | REVIEW |
| | |
| | LANDSCAPE, IRRIGATION - BRYAN DONAHUE, RLA, WGI: BRYAN |
| | DONAHUE DIGITAL SEAL/SIGNATURE COMPLY WITH FS481. I WAS |
| | UNABLE TO LOCATE LANDSCAPE ARCHITECT BUSINESS NUMBER |
| | 7055 AT DBPR WEBSITE (SEARCHED LICENSE NUMBER AND NAME |
| | OF "WGI"). PLEASE ADDRESS. |
| | REGARDING IP SHEETS, PLEASE NOTE SCOPE IN FS |
| | 481.303(7); CONSULT WITH YOUR BOARD TO DETERMINE WHO |
| | CAN SIGN/SEAL THESE PAGES |
| | |
| | STRUCTURAL SHEETS - ANDREW P. SULLIVAN, PE, |
| | MCNAMARA-SALVIA: DIGITAL SEAL/SIGNATURE AND TITLE BLOCK |
| | COMPLY WITH FS471, BUT NEW SHEETS SUBMITTED 2ND CYCLE |
| | NEED REVIEW |
| | |
| | MECHANICAL, PLUMBING, ELECTRICAL, FIRE PROTECTION |
| | SHEETS - STEVEN FELLER PE, STEVEN FELLER PE LLC: |
| | DIGITAL SEAL/SIGNATURE AND TITLE BLOCK COMPLY WITH |
| | FS471, BUT NEW SHEETS SUBMITTED 2ND CYCLE NEED REVIEW. |
| | FS 471.0195, DBPR WEBSITE DOES NOT INDICATE THAT |
| | ENGINEER HAS COMPLETED ADVANCED FLORIDA BUILDING CODE |
| | COURSE. ENGINEER MAY HAVE ALREADY TAKEN THIS COURSE |
| | (WHICH WAS REQUIRED TO BE COMPLETED BY 6/30/2016, BUT |
| | EVIDENCE OF SUCH MUST BE SENT TO FBPE SO THE ENGINEER'S |
| | RECORD ON WWW.MYFLORIDALICENSE.COM CAN BE UPDATED. |
| | PLEASE ADDRESS. |
| | |
| | LOW VOLTAGE PLANS (SHEETS 840 LVC1 THROUGH 849 CHSLV |
| | 7.1), NOT SIGNED AND SEALED. LOW VOLTAGE REQUIRES A |
| | SEPARATE PERMIT; THESE PAGES HAVE NOT BEEN REVIEWED. |
| | |
| | POOL PLANS, OFELIA TABOADA, PE AND AQUADYNAMICS (SHEETS |
| | 850 SP1.0 THROUGH 862 SP2.04), FS 471.0195, DBPR |
| | WEBSITE DOES NOT INDICATE THAT ENGINEER HAS COMPLETED |
| | ADVANCED FLORIDA BUILDING CODE COURSE. ENGINEER MAY |
| | HAVE ALREADY TAKEN THIS COURSE (WHICH WAS REQUIRED TO |
| | BE COMPLETED BY 6/30/2016, BUT EVIDENCE OF SUCH MUST BE |
| | SENT TO FBPE SO THE ENGINEER'S RECORD ON |
| | WWW.MYFLORIDALICENSE.COM CAN BE UPDATED. PLEASE |
| | ADDRESS. |
| | |
| | SUPPORTING DOCUMENTS (PROVISO: ANY NEW DOCUMENTS |
| | SUBMITTED FOR ANOTHER REVIEW CYCLE NEED REVIEW): |
| | ENERGY CALCS INPUT REPORT SIGNATURE/SEAL OK |
| | ENERGY CALCULATION REPORT SIGNATURE/SEAL OK |
| | EXPEDITE EMAIL RE: EXPEDITE: PLEASE PROVIDE (DOCUMENT |
| | ON FILE DOES NOT INCLUDE EMAIL OR LETTER FROM MAYOR |
| | AUTHORIZING EXPEDITED REVIEWS WITH NO FEE) |
| | FIRE STANDPIPE CALCS SIGNATURE/SEAL OK |
| | |
| | SMOKE CONTROL RATIONAL ANALYSIS: THIS DOCUMENTS LACKS |
| | SIGNATURE/SEAL, LACKS TITLE BLOCK IN COMPLIANCE WITH |
| | FS471 AND FAC61G15-23.002 (CERTIFICATE OF AUTHORIZATION |
| | FOR SLS FIRE PROTECTION ENGINEERS, NAME AND LICENSE |
| | NUMBER OF INDIVIDUAL PREPARING THE DOCUMENT) |
| | |
| | HVAC CALCS: PREPARED BY STEVEN FELLER, LACKS |
| | SIGNATURE/SEAL. |
| | |
| | |
| | |
| | |
| | |
| | |
| | |
| | |
| | |
| | |
| | |
| | |
| | |
| | |