| 2017-11-20 15:51:12 | ****CORRECTIONS**** | | | | | | SAMANTHA HILL | | | BUILDING PLANS EXAMINER | | | [email protected] | | | 561-805-6724 | | | | | | FBC = FLORIDA BUILDING CODE, 5TH EDITION (2014) | | | FBC B = FBC BUILDING | | | FBC EB = FBC EXISTING BUILDING | | | FBC A = FBC ACCESSIBILITY | | | FBC EC = FBC ENERGY CONSERVATION | | | | | | 1. SEE SHEET SP-1.0.1. IT APPEARS THAT PARKING | | | CONFIGURATION AND DUMPSTER LOCATION IS BEING CHANGED. | | | THIS PERMIT IS FOR THE BUILDING ONLY; PARKING LOT | | | STRIPING AND DUMPSTER ENCLOSURE REQUIRE SEPARATE | | | PERMITS, FBC 107. | | | | | | THERE IS AN OPEN PAVING PERMIT FOR THIS ADDRESS | | | (16080710); IS THIS ASSOCIATED WITH THIS PROJECT? THAT | | | PERMIT HAS A REQUIREMENT THAT IT CANNOT OBTAIN CERT OF | | | COMPLETION UNTIL LANDSCAPING IS FINALED. WHEN YOU | | | SCHEDULE LANDSCAPE FINAL, PLEASE ALSO SCHEDULE ZONING | | | FINAL FOR THE OPEN PAVING PERMIT 16080710 TO AVOID THE | | | PERMIT FROM EXPIRING. | | | | | | IT DOES NOT APPEAR THAT A DUMPSTER ENCLOSURE PERMIT HAS | | | BEEN APPLIED FOR. PLEASE DO SO AT THIS TIME. | | | | | | 2. A2.0.1, RAMP DOES NOT APPEAR TO HAVE EDGE | | | PROTECTION, REVISE PLAN TO SHOW COMPLIANCE WITH FBC A | | | 405.9, EDGE PROTECTION. | | | | | | 3. A2.0.1, RAMP EXTENSIONS ARE NOT CLEAR. SEE FBC A | | | 405.8, 505, AND PROVIDE ADDITIONAL DETAILS AND/OR | | | DIMENSIONS TO SHOW COMPLIANCE. FOR INSTANCE, EXTENSION | | | LENGTH NOT CLEAR. DETAIL 5 APPEARS TO SHOW EXTENSIONS | | | WHICH DO NOT RETURN TO THE GROUND OR GUARD. | | | |
|