| Date |
Text |
| 2017-10-30 14:34:11 | SUFFICIENCY REVIEW: FBC 2014 5TH ED. RESIDENTIAL |
| | FBC 2014 EXISTING BUILDING |
| | |
| | THE APPLICATION IS DEFICIENT AS NO PLANS HAVE BEEN |
| | PROVIDED EXCEPT A SURVEY. |
| | PLEASE PROVIDE PLANS AS REQUIRED BELOW |
| | |
| | 553.792 - BUILDING PERMIT APPLICATION TO LOCAL |
| | GOVERNMENT. |
| | (1) WITHIN 10 DAYS OF AN APPLICANT SUBMITTING AN |
| | APPLICATION TO THE LOCAL GOVERNMENT, THE LOCAL |
| | GOVERNMENT SHALL ADVISE THE APPLICANT WHAT INFORMATION, |
| | IF ANY, IS NEEDED TO DEEM THE APPLICATION PROPERLY |
| | COMPLETED IN COMPLIANCE WITH THE FILING REQUIREMENTS |
| | PUBLISHED BY THE LOCAL GOVERNMENT. |
| | |
| | FBC107.1 GENERAL. SUBMITTAL DOCUMENTS CONSISTING OF |
| | CONSTRUCTION DOCUMENTS, STATEMENT OF SPECIAL |
| | INSPECTIONS, GEOTECHNICAL REPORT AND OTHER DATA SHALL |
| | BE SUBMITTED IN TWO OR MORE SETS WITH EACH PERMIT |
| | APPLICATION. |
| | |
| | FBC-107.2.1 INFORMATION ON CONSTRUCTION DOCUMENTS. ALL |
| | INFORMATION, DRAWINGS, SPECIFICATIONS AND ACCOMPANYING |
| | DATA SHALL BEAR THE NAME AND SIGNATURE OF THE PERSON |
| | RESPONSIBLE FOR THE DESIGN. |
| | |
| | 107.2.1 INFORMATION ON CONSTRUCTION DOCUMENTS. |
| | CONSTRUCTION DOCUMENTS SHALL BE DIMENSIONED AND DRAWN |
| | UPON SUITABLE MATERIAL. ELECTRONIC MEDIA DOCUMENTS |
| | SHALL BE SUBMITTED WHEN APPROVED BY THE BUILDING |
| | OFFICIAL. CONSTRUCTION DOCUMENTS SHALL BE OF SUFFICIENT |
| | CLARITY TO INDICATE THE LOCATION, NATURE AND EXTENT OF |
| | THE WORK PROPOSED AND SHOW IN DETAIL THAT IT WILL |
| | CONFORM TO THE PROVISIONS OF THIS CODE AND RELEVANT |
| | LAWS, ORDINANCES, RULES AND REGULATIONS, AS DETERMINED |
| | BY THE BUILDING OFFICIAL. SUCH DRAWINGS AND |
| | SPECIFICATIONS SHALL CONTAIN INFORMATION, IN THE FORM |
| | OF NOTES OR OTHERWISE, AS TO THE QUALITY OF MATERIALS, |
| | WHERE QUALITY IS ESSENTIAL TO CONFORMITY WITH THE |
| | TECHNICAL CODES. SUCH INFORMATION SHALL BE SPECIFIC, |
| | AND THE TECHNICAL CODES SHALL NOT BE CITED AS A WHOLE |
| | OR IN PART, NOR SHALL THE TERM "LEGAL" OR ITS |
| | EQUIVALENT BE USED AS A SUBSTITUTE FOR SPECIFIC |
| | INFORMATION. ALL INFORMATION, DRAWINGS, SPECIFICATIONS |
| | AND ACCOMPANYING DATA SHALL BEAR THE NAME AND SIGNATURE |
| | OF THE PERSON RESPONSIBLE FOR THE DESIGN. (SEE ALSO |
| | SECTION 107.3.5). |
| | |
| | 107.3.5.3 RESIDENTIAL (ONE AND TWO-FAMILY) |
| | PROVIDE DETAILS AS MAY BE APPLICABLE REGARDING ITEMS |
| | 3-13 BELOW: |
| | |
| | 3. SMOKE DETECTOR LOCATIONS |
| | 4. EGRESS |
| | EGRESS WINDOW SIZE AND LOCATION STAIRS CONSTRUCTION |
| | REQUIREMENTS |
| | 5. STRUCTURAL REQUIREMENTS SHALL INCLUDE: |
| | WALL SECTION FROM FOUNDATION THROUGH ROOF, INCLUDING |
| | ASSEMBLY AND MATERIALS CONNECTOR |
| | TABLES |
| | TERMITE PROTECTION |
| | DESIGN LOADS |
| | WIND REQUIREMENTS |
| | BUILDING ENVELOPE |
| | FOUNDATION |
| | WALL SYSTEMS |
| | FLOOR SYSTEMS |
| | ROOF SYSTEMS |
| | 6. ACCESSIBILITY REQUIREMENTS: SHOW/IDENTIFY ACCESSIBLE |
| | BATH |
| | 7. IMPACT RESISTANT COVERINGS OR SYSTEMS |
| | 9. ELECTRICAL: |
| | ELECTRIC SERVICE RISER WITH WIRE SIZES, CONDUIT DETAIL |
| | AND GROUNDING DETAIL. COMPLETE |
| | LOAD CALCULATIONS, PANEL SCHEDULES |
| | 10.MECHANICAL: |
| | EQUIPMENT AND LOCATION, DUCT SYSTEMS |
| | 11.PLUMBING: |
| | PLUMBING RISER |
| | 12.GAS: |
| | GAS PIPING |
| | VENTING |
| | COMBUSTION AIR |
| | CHIMNEYS AND VENTS |
| | APPLIANCES |
| | TYPE OF GAS |
| | FIREPLACES |
| | LP TANK LOCATION |
| | RISER DIAGRAM/SHUTOFFS |
| | 13.ENERGY CALCULATIONS |
| | |
| | STEVEN KENNEDY, CBO |
| | ASSISTANT BUILDING OFFICIAL |
| | (561) 805-6710 |
| | [email protected] |
| | |