| 2017-10-13 11:52:45 | ***CORRECTIONS*** |
| | |
| | SAMANTHA HILL |
| | BUILDING PLANS EXAMINER |
| | [email protected] |
| | 561-805-6724 |
| | |
| | FBC = FLORIDA BUILDING CODE 2014 |
| | FBC B = FBC BUILDING |
| | FBC EB = FBC EXISTING BUILDING |
| | FBC A = FBC ACCESSIBILITY |
| | FBC EC = FBC ENERGY CONSERVATION |
| | |
| | 1. APPLICATION IS NOT CONSISTENT WITH THE PLANS; |
| | APPLICATION STATES THIS IS "INTERIOR DEMOLITION" BUT |
| | PLANS SHOW STRUCTURAL IMPROVEMENTS, PLEASE CLARIFY. |
| | |
| | 2. PLEASE SEE FLORIDA DECLARATORY STATEMENT |
| | (WWW.FLORIDABUILDING.ORG) DS2014-61 REGARDING |
| | STRUCTURAL ALTERATIONS TO THRESHOLD BUILDINGS. IT |
| | APPEARS THAT THE PROPOSED WORK IS A STRUCTURAL |
| | ALTERATION TO A THRESHOLD BUILDING. |
| | |
| | THRESHOLD BUILDING / FL S. S. 553.71(7) "THRESHOLD |
| | BUILDING" MEANING ANY BUILDING WHICH IS GREATER THAN |
| | (3) STORIES OR 50 FT. IN HEIGHT, OR WHICH HAS AN |
| | ASSEMBLY OCCUPANCY CLASSIFICATION AS DEFINED IN THE |
| | FLORIDA BUILDING CODE WHICH EXCEEDS 5,000 SQ. FT. IN |
| | AREA AND AN OCCUPANT CONTENT OF GREATER THAN 500 |
| | PERSONS. |
| | |
| | A) 109.3.6.1 THRESHOLD INSPECTION PLAN. THE ENFORCING |
| | AGENCY SHALL REQUIRE A (WRITTEN/ TYPED) SPECIAL |
| | INSPECTOR TO PERFORM STRUCTURAL INSPECTIONS ON A |
| | THRESHOLD BUILDING PURSUANT TO A STRUCTURAL INSPECTION |
| | PLAN PREPARED BY THE ENGINEER OF RECORD. THE STRUCTURAL |
| | INSPECTION PLAN MUST BE SUBMITTED TO THE ENFORCING |
| | AGENCY PRIOR TO THE ISSUANCE OF A BUILDING PERMIT FOR |
| | THE CONSTRUCTION OF A THRESHOLD BUILDING. THE PURPOSE |
| | OF THE STRUCTURAL INSPECTION PLAN IS TO PROVIDE |
| | SPECIFIC INSPECTION PROCEDURES AND SCHEDULES SO THAT |
| | THE BUILDING CAN BE ADEQUATELY INSPECTED FOR COMPLIANCE |
| | WITH THE PERMITTED DOCUMENTS. |
| | |
| | B) THRESHOLD INSPECTOR: WPB AMENDMENT 109.3.6.2 W.P.B. |
| | CONSTRUCTION SERVICES DEPARTMENT REQUEST FOR THRESHOLD |
| | BUILDINGS A SPECIAL INSPECTOR AS REQUIRED BY FL S S |
| | 553.79(5) FLORIDA STATUTES TO THE MINIMUM INSPECTIONS |
| | REQUIRED BY THIS CODE. THE THRESHOLD INSPECTION FORMS |
| | ARE REQUIRED TO BE FILED OUT BY ALL PARTIES WITH |
| | INTEREST, NOTARIZED AND RETURNED TO THIS OFFICE, AND |
| | REVIEWED AND APPROVED BEFORE PERMIT ISSUANCE WILL TAKE |
| | PLACE. |
| | |
| | C) THRESHOLD BLDG., REQUIRED STATEMENT W.P.B. AMENDMENT |
| | 110.3.7.4.4, FS553.79(7)(D): ALL PLANS FOR THE BUILDING |
| | WHICH ARE REQUIRED TO BE SIGNED AND SEALED BY THE |
| | ARCHITECT OR ENGINEER OF RECORD CONTAIN A STATEMENT |
| | THAT, TO THE BEST OF THE ARCHITECT'S OR ENGINEER'S |
| | KNOWLEDGE, THE PLANS AND SPECIFICATIONS COMPLY WITH THE |
| | APPLICABLE MINIMUM BUILDING CODES AND THE APPLICABLE |
| | FIRESAFETY STANDARDS AS DETERMINED BY THE LOCAL |
| | AUTHORITY IN ACCORDANCE WITH THIS CHAPTER AND CHAPTER |
| | 633. |
| | |
| | 3. PLEASE REVISE PLAN TO INCLUDE THRESHOLD INSPECTION |
| | PLAN AND TO INCLUDE THE REQUIRED THRESHOLD STATEMENT. |
| | WHEN RESUBMITTING, PROVIDE THREE SETS OF PLANS. |
| | |
| | THE SPECIAL INSPECTOR AGREEMENT AND RESUMES MAY BE SENT |
| | VIA EMAIL. RESUMES FOR THE SI, CONTRACTOR, AND JOB |
| | INSPECTOR(S) SHOWING EXPERIENCE WITH PROJECTS OF THIS |
| | TYPE ARE REQUIRED. |
| | |
| | (SI AGREEMENT AND G&P SENT TO [email protected] ON |
| | 10/13/17) |
| | |
| | |