| 2018-05-17 12:50:00 | 4TH REVIEW: FBC 2014 5TH ED. RESIDENTIAL |
| | |
| | APPROVED WITH EXCEPTIONS |
| | |
| | THIS REVIEW IS INTENDED TO ALLOW FOR ISSUANCE WITH |
| | EXCEPTIONS REQUIRING ADDITIONAL SUBMITTALS PRIOR TO |
| | TIME OF INSPECTION. |
| | |
| | THE FOLLOWING INFORMATION BELOW NUMBERED AS NOTED IN |
| | PREVIOUS REVIEWS MAY BE SUBMITTED SUBSEQUENT TO |
| | ISSUANCE: |
| | |
| | 9- ENERGY CALCULATIONS SUBMITTED: |
| | |
| | RESBMIT PAGE 1 IDENTIFYING THE CEILING INSULATION VALUE |
| | AS R-22. THE FORM CURRENTLY INDICATES 0.0. |
| | |
| | 10- PROVIDE PRODUCT APPROVAL (TWO COPIES) AS REQUIRED |
| | BY FAC 61G20-3.001 FOR: |
| | A) ENTRY DOOR SIZE AS SHOWN ON PLANS AND TYPE OF DOOR |
| | SPECIFIED ON PLANS (WOOD). PROVIDE 2 COPIES. CLARIFY |
| | WHY SUBMITTING FLORIDA PRODUCT APPROVAL FL16708-R8. |
| | THIS IS NOT APPROVED YET AND IS NOT WOOD DOOR AND SIZE |
| | DOESN'T MATCH PLANS. |
| | B) ROUND WINDOWS AS SHOWN ON PLANS. REPEAT COMMENT. |
| | D) CLEARLY SPECIFY MULLION SIZE WINDOW MULLIONS NOA |
| | 17-0630.01 SUBMITTED TO VERIFY COMPLIANCE WITH THE |
| | CALCULATED DESIGN PRESSURES. |
| | E) BALCONY UNDERLAYMENT SPECIFIED ON PLANS. NOTE: NEED |
| | PRODUCT APPROVAL THAT IS DESIGNED TO RECEIVE TILE AS |
| | SPECIFIED ON PLANS. CLEARLY IDENTIFY SPECIFIC ASSEMBLY |
| | TO BE USED. IF SELECTED ASSEMBLY DOESN'T MEET THE |
| | DESIGN PRESSURES FOR ALL ZONES, THEN SIGNED AND SEALED |
| | RAS 117 CALCULATIONS WILL BE REQUIRED. |
| | |
| | |
| | STEVEN KENNEDY, CBO |
| | ASSISTANT BUILDING OFFICIAL |
| | (561) 805-6710 |
| | |