| 2018-03-14 17:33:51 | 03/14/18 |
| | NOTE: COMPLETE THE NEW RESIDENCE INFORMATION: AREA, |
| | NUMBER OF BEDROOMS, ETC. |
| 2018-03-08 15:15:23 | NEW SINGLE FAMILY RESIDENCE (R3) SECOND BUILDING REVIEW |
| | CHECKLIST. |
| | CODE: FBC 5TH EDITION (2014). |
| | |
| | 1- IMPACT FEES: |
| | BEFORE A PERMIT TO CONSTRUCT CAN BE ISSUED, IMPACT FEES |
| | MUST BE PAID TO PALM BEACH COUNTY. UPON APPROVAL, ONE |
| | SET OF PLANS SHALL BE SIGNED OUT AND SUBMITTED TO PALM |
| | BEACH COUNTY FOR AN IMPACT FEE REVIEW. THE PLANS WITH |
| | THE IMPACT FEE STAMP AND A COPY OF THE PAID RECEIPT |
| | MUST BE RETURNED TO THE CITY BUILDING DEPARTMENT BEFORE |
| | THE BUILDING PERMIT CAN BE ISSUED. FOR INFORMATION CALL |
| | PALM BEACH COUNTY IMPACT FEES AT (561) 233-5025. |
| | |
| | 2- GENERAL CONTRACTOR CAN NOT DO THE METAL ROOFING. |
| | SEC. 489.113(3) FLORIDA STATUTE. GENERAL CONTRACTOR |
| | NEEDS TO SUBCONTRACT THE METAL ROOFING WORK TO A |
| | LICENSED ROOFING CONTRACTOR. SEPARATE ROOFING PERMIT |
| | APPLICATION NEEDS TO BE FILL UP BY THE LICENSED ROOFING |
| | CONTRACTOR. |
| | RESPONSE: REPEAT COMMENT. |
| | |
| | 3- PROVIDE DRAINAGE PLAN SHOWING COMPLIANCE WITH SEC. |
| | R401.3 FBC-RESIDENTIAL. |
| | RESPONSE: REPEAT COMMENT. |
| | 4-PROVIDE DETAILS AND SPECIFICATIONS FOR STAIRWAY |
| | FIREBLOCKING AS REQUIRED BY SEC. R302.11 |
| | FBC-RESIDENTIAL. |
| | RESPONSE: REPEAT COMMENT. |
| | 5- PROVIDE DETAILS AND SPECIFICATIONS FOR DRAFSTOPPING |
| | ON THE SECOND FLOOR FRAMING PLAN AS REQUIRED BY SEC. |
| | R302.12 FBC-RESIDENTIAL. AND INDICATE ON PLANS |
| | DRAFSTOPPING LOCATION. |
| | RESPONSE: REPEAT COMMENT. |
| | 6- PROVIDE COMPLETE GABLE END DETAIL COMPLYING WITH |
| | SEC. R609.4 FBC-RESIDENTIAL. CLEARLY SPECIFY ALL |
| | FRAMING MEMBERS AND FASTENERS. |
| | RESPONSE TO DETAIL 9/A2.2 SUBMITTED: DON'T CITE ANY |
| | SECTIONS OR TABLE FROM THE CODE. DESIGNER OF RECORD IS |
| | RESPONSIBLE FOR THE STRUCTURAL DESIGN OF THE GABLE END. |
| | CLEARLY SPECIFY ALL CONNECTORS. SPECIFY ALL GABLE END |
| | BRACING MEMBERS NAIL SIZE AND NUMBER. NOTE: ROOF |
| | SHEATHING NAILS NEED TO BE 8D RING SHANK. REVISE AS |
| | REQUIRED. |
| | |
| | 7- PROVIDE ICC EVALUATION REPORT FOR SPRAY INSULATION |
| | SPECIFIED FOR THE UNVENTED ATTIC. ARCHITECT TO |
| | REVIEW/APPROVE PRIOR TO SUBMITTAL. SEC. R316 |
| | FBC-RESIDENTIAL. |
| | RESPONSE: REPEAT COMMENT. |
| | |
| | 8- STRUCTURAL NOTES AND TRUSS DESIGN CRITERIA ON SHEET |
| | S2 ARE REFERENCING ASCE 7-16. THE CURRENT ASCE 7 |
| | EDITION ADOPTED WITH THE 2014 FBC IS THE ASCE 7-10 NOT |
| | ASCE 7-16. REVISE AS REQUIRED BY CHAPTER 46 |
| | FBC-RESIDENTIAL. |
| | RESPONSE: REPEAT COMMENT. |
| | |
| | 9- ENERGY CALCULATIONS SUBMITTED: |
| | A) NEW FORM R405-2017 WAS SUBMITTED. THIS FORM IS |
| | INCORRECT. THIS BUILDING IS BEING REVIEWED UNDER THE |
| | 2014 FBC. NEED TO RE-SUBMIT THE FORM R405-2014 THAT WAS |
| | SUBMITTED THE FIRST TIME. SEC. R101.5.1.1.2 FBC-ENERGY |
| | CONSERVATION, 5TH EDITION (2014). |
| | |
| | B) NUMBER OF BEDROOMS ON ITEM #4 IS INCORRECT. SEE |
| | PLANS AND REVISE AS REQUIRED. SEC. R101.5.1.1.2 |
| | FBC-ENERGY CONSERVATION. |
| | |
| | C) ROOF DECK INSULATION R-VALUE SPECIFIED ON ITEM #10 |
| | IS INCORRECT. SEE PLANS AND REVISE AS REQUIRED. SEC. |
| | R101.5.1.1.2 FBC-ENERGY CONSERVATION. |
| | |
| | D) SPACES INFORMATION ON PAGE 2 OF 4 IS INCORRECT. NED |
| | TO INCLUDE THE KITCHEN AND CORRECT NUMBER OF BEDROOMS |
| | AND PEOPLE. SEE PLANS AND REVISE AS REQUIRED. SEC. |
| | R101.5.1.1.2 FBC-ENERGY CONSERVATION. |
| | REPEAT COMMENT. |
| | |
| | E) ROOF INFORMATION ON PAGE 2 OF 4 IS INCORRECT. REVISE |
| | AS REQUIRED TO MATCH PLANS. THE TYPE OF ROOF IS GABLE |
| | NOT HIP AND THE ROOF MATERIAL IS METAL ROOF NOT |
| | SHINGLES. SEC. R101.5.1.1.2 FBC-ENERGY CONSERVATION. |
| | REPEAT COMMENT. |
| | |
| | F) THE WINDOWS INFORMATION ON PAGE 3 OF 4 DOESN'T MATCH |
| | PLANS. REVISE THE WINDOWS ORIENTATION AND AREA TO MATCH |
| | PLANS. SEC. R101.5.1.1.2 FBC-ENERGY CONSERVATION. |
| | REPEAT COMMENT. |
| | |
| | I) PROVIDE THE COMPLETE INSPECTION CHECKLIST REQUIRED |
| | BY SEC. R405.4.2 (2) FBC-ENERGY CONSERVATION. |
| | REPEAT COMMENT. |
| | |
| | J) PROVIDE THE COMPLETE EPL DISPLAY CARD SIGNED BY THE |
| | BUILDER AS REQUIRED BY SEC. R405.4.3 FBC-ENERGY |
| | CONSERVATION. |
| | REPEAT COMMENT. |
| | |
| | 10- PROVIDE PRODUCT APPROVAL (TWO COPIES) AS REQUIRED |
| | BY FAC 61G20-3.001 FOR: |
| | A) ENTRY DOOR SIZE AS SHOWN ON PLANS AND TYPE OF DOOR |
| | SPECIFIED ON PLANS (WOOD). PROVIDE 2 COPIES. CLARIFY |
| | WHY SUBMITTING FLORIDA PRODUCT APPROVAL FL16708-R8. |
| | THIS IS NOT APPROVED YET AND IS NOT WOOD DOOR AND SIZE |
| | DOESN'T MATCH PLANS. |
| | |
| | B) ROUND WINDOWS AS SHOWN ON PLANS. REPEAT COMMENT. |
| | |
| | D) WINDOW MULLIONS NOA 17-0630.01 SUBMITTED. CLEARLY |
| | SPECIFY MULLION SIZE TO VERIFY COMPLIANCE WITH THE |
| | CALCULATED DESIGN PRESSURES. AND, PROVIDE LEGIBLE |
| | DRAWINGS. PLEAS PRINT THEM IN LANDSCAPE FORMAT SO |
| | DRAWINGS ARE MORE LEGIBLE. |
| | |
| | E) BALCONY UNDERLAYMENT SPECIFIED ON PLANS. NOTE: NEED |
| | PRODUCT APPROVAL THAT IS DESIGNED TO RECEIVE TILE AS |
| | SPECIFIED ON PLANS. CLEARLY IDENTIFY SPECIFIC ASSEMBLY |
| | TO BE USED. IF SELECTED ASSEMBLY DOESN'T MEET THE |
| | DESIGN PRESSURES FOR ALL ZONES, THEN SIGNED AND SEALED |
| | RAS 117 CALCULATIONS WILL BE REQUIRED. |
| | RESPONSE: KEMPEROL MEMBRANE WATERPROOFING SYSTEM |
| | SUBMITTED IS FOR CONCRETE DECKS. THIS IS A WOOD DECK. |
| | PROVIDE PROPER PRODUCT APPROVAL. AND IDENTIFY SELECTED |
| | ASSEMBLY AS REQUESTED ABOVE. |
| | |
| | 11- DESIGNER OF RECORD TO APPROVE ABOVE PRODUCT |
| | APPROVALS AS REQUIRED BY SEC. 107.3.4.1 CITY |
| | AMENDMENTS. |
| | |
| | NOTE: PROVIDE MANUFACTURER'S CUT SHEETS FOR SECOND |
| | FLOOR EGRESS WINDOWS TO VERIFY COMPLIANCE WITH ALL MIN. |
| | OPENING REQUIREMENTS. SOME WINDOWS DEPENDING ON THE |
| | SPECIFIC MODEL DON'T COMPLY WITH ALL THE REQUIREMENTS. |
| | THIS WILL AVOID CONFLICTS/DELAYS. |
| | |
| | |
| | *** PLEASE PROVIDE RESPONSE LETTER ADDRESING EACH |
| | COMMENT TO HELP EXPEDITE THE REVIEW PROCESS. |
| | **** PLEASE INSERT ANY REVISED DRAWING AND REMOVE OLD |
| | DRAWING. DON'T STAPLE OLD DRAWINGS. SUBMIT ALL DRAWINGS |
| | FOR REFERENCE. |
| | |
| | |
| | IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT |
| | JULIO GOMEZ |
| | COMMERCIAL COMBINATION PLANS EXAMINER |
| | DEVELOPMENT SERVICES DEPARTMENT |
| | BUILDING DIVISION |
| | (561)805-6712 |
| | [email protected] |