Plan Review Notes
Plan Review Notes For Permit 17100284
Permit Number 17100284
Review Stop B
Sequence Number 2
Notes
Date Text
2018-03-14 17:33:5103/14/18
 NOTE: COMPLETE THE NEW RESIDENCE INFORMATION: AREA,
 NUMBER OF BEDROOMS, ETC.
2018-03-08 15:15:23NEW SINGLE FAMILY RESIDENCE (R3) SECOND BUILDING REVIEW
 CHECKLIST.
 CODE: FBC 5TH EDITION (2014).
  
 1- IMPACT FEES:
 BEFORE A PERMIT TO CONSTRUCT CAN BE ISSUED, IMPACT FEES
 MUST BE PAID TO PALM BEACH COUNTY. UPON APPROVAL, ONE
 SET OF PLANS SHALL BE SIGNED OUT AND SUBMITTED TO PALM
 BEACH COUNTY FOR AN IMPACT FEE REVIEW. THE PLANS WITH
 THE IMPACT FEE STAMP AND A COPY OF THE PAID RECEIPT
 MUST BE RETURNED TO THE CITY BUILDING DEPARTMENT BEFORE
 THE BUILDING PERMIT CAN BE ISSUED. FOR INFORMATION CALL
 PALM BEACH COUNTY IMPACT FEES AT (561) 233-5025.
  
 2- GENERAL CONTRACTOR CAN NOT DO THE METAL ROOFING.
 SEC. 489.113(3) FLORIDA STATUTE. GENERAL CONTRACTOR
 NEEDS TO SUBCONTRACT THE METAL ROOFING WORK TO A
 LICENSED ROOFING CONTRACTOR. SEPARATE ROOFING PERMIT
 APPLICATION NEEDS TO BE FILL UP BY THE LICENSED ROOFING
 CONTRACTOR.
 RESPONSE: REPEAT COMMENT.
  
 3- PROVIDE DRAINAGE PLAN SHOWING COMPLIANCE WITH SEC.
 R401.3 FBC-RESIDENTIAL.
 RESPONSE: REPEAT COMMENT.
 4-PROVIDE DETAILS AND SPECIFICATIONS FOR STAIRWAY
 FIREBLOCKING AS REQUIRED BY SEC. R302.11
 FBC-RESIDENTIAL.
 RESPONSE: REPEAT COMMENT.
 5- PROVIDE DETAILS AND SPECIFICATIONS FOR DRAFSTOPPING
 ON THE SECOND FLOOR FRAMING PLAN AS REQUIRED BY SEC.
 R302.12 FBC-RESIDENTIAL. AND INDICATE ON PLANS
 DRAFSTOPPING LOCATION.
 RESPONSE: REPEAT COMMENT.
 6- PROVIDE COMPLETE GABLE END DETAIL COMPLYING WITH
 SEC. R609.4 FBC-RESIDENTIAL. CLEARLY SPECIFY ALL
 FRAMING MEMBERS AND FASTENERS.
 RESPONSE TO DETAIL 9/A2.2 SUBMITTED: DON'T CITE ANY
 SECTIONS OR TABLE FROM THE CODE. DESIGNER OF RECORD IS
 RESPONSIBLE FOR THE STRUCTURAL DESIGN OF THE GABLE END.
 CLEARLY SPECIFY ALL CONNECTORS. SPECIFY ALL GABLE END
 BRACING MEMBERS NAIL SIZE AND NUMBER. NOTE: ROOF
 SHEATHING NAILS NEED TO BE 8D RING SHANK. REVISE AS
 REQUIRED.
  
 7- PROVIDE ICC EVALUATION REPORT FOR SPRAY INSULATION
 SPECIFIED FOR THE UNVENTED ATTIC. ARCHITECT TO
 REVIEW/APPROVE PRIOR TO SUBMITTAL. SEC. R316
 FBC-RESIDENTIAL.
 RESPONSE: REPEAT COMMENT.
  
 8- STRUCTURAL NOTES AND TRUSS DESIGN CRITERIA ON SHEET
 S2 ARE REFERENCING ASCE 7-16. THE CURRENT ASCE 7
 EDITION ADOPTED WITH THE 2014 FBC IS THE ASCE 7-10 NOT
 ASCE 7-16. REVISE AS REQUIRED BY CHAPTER 46
 FBC-RESIDENTIAL.
 RESPONSE: REPEAT COMMENT.
  
 9- ENERGY CALCULATIONS SUBMITTED:
 A) NEW FORM R405-2017 WAS SUBMITTED. THIS FORM IS
 INCORRECT. THIS BUILDING IS BEING REVIEWED UNDER THE
 2014 FBC. NEED TO RE-SUBMIT THE FORM R405-2014 THAT WAS
 SUBMITTED THE FIRST TIME. SEC. R101.5.1.1.2 FBC-ENERGY
 CONSERVATION, 5TH EDITION (2014).
  
 B) NUMBER OF BEDROOMS ON ITEM #4 IS INCORRECT. SEE
 PLANS AND REVISE AS REQUIRED. SEC. R101.5.1.1.2
 FBC-ENERGY CONSERVATION.
  
 C) ROOF DECK INSULATION R-VALUE SPECIFIED ON ITEM #10
 IS INCORRECT. SEE PLANS AND REVISE AS REQUIRED. SEC.
 R101.5.1.1.2 FBC-ENERGY CONSERVATION.
  
 D) SPACES INFORMATION ON PAGE 2 OF 4 IS INCORRECT. NED
 TO INCLUDE THE KITCHEN AND CORRECT NUMBER OF BEDROOMS
 AND PEOPLE. SEE PLANS AND REVISE AS REQUIRED. SEC.
 R101.5.1.1.2 FBC-ENERGY CONSERVATION.
 REPEAT COMMENT.
  
 E) ROOF INFORMATION ON PAGE 2 OF 4 IS INCORRECT. REVISE
 AS REQUIRED TO MATCH PLANS. THE TYPE OF ROOF IS GABLE
 NOT HIP AND THE ROOF MATERIAL IS METAL ROOF NOT
 SHINGLES. SEC. R101.5.1.1.2 FBC-ENERGY CONSERVATION.
 REPEAT COMMENT.
  
 F) THE WINDOWS INFORMATION ON PAGE 3 OF 4 DOESN'T MATCH
 PLANS. REVISE THE WINDOWS ORIENTATION AND AREA TO MATCH
 PLANS. SEC. R101.5.1.1.2 FBC-ENERGY CONSERVATION.
 REPEAT COMMENT.
  
 I) PROVIDE THE COMPLETE INSPECTION CHECKLIST REQUIRED
 BY SEC. R405.4.2 (2) FBC-ENERGY CONSERVATION.
 REPEAT COMMENT.
  
 J) PROVIDE THE COMPLETE EPL DISPLAY CARD SIGNED BY THE
 BUILDER AS REQUIRED BY SEC. R405.4.3 FBC-ENERGY
 CONSERVATION.
 REPEAT COMMENT.
  
 10- PROVIDE PRODUCT APPROVAL (TWO COPIES) AS REQUIRED
 BY FAC 61G20-3.001 FOR:
 A) ENTRY DOOR SIZE AS SHOWN ON PLANS AND TYPE OF DOOR
 SPECIFIED ON PLANS (WOOD). PROVIDE 2 COPIES. CLARIFY
 WHY SUBMITTING FLORIDA PRODUCT APPROVAL FL16708-R8.
 THIS IS NOT APPROVED YET AND IS NOT WOOD DOOR AND SIZE
 DOESN'T MATCH PLANS.
  
 B) ROUND WINDOWS AS SHOWN ON PLANS. REPEAT COMMENT.
  
 D) WINDOW MULLIONS NOA 17-0630.01 SUBMITTED. CLEARLY
 SPECIFY MULLION SIZE TO VERIFY COMPLIANCE WITH THE
 CALCULATED DESIGN PRESSURES. AND, PROVIDE LEGIBLE
 DRAWINGS. PLEAS PRINT THEM IN LANDSCAPE FORMAT SO
 DRAWINGS ARE MORE LEGIBLE.
  
 E) BALCONY UNDERLAYMENT SPECIFIED ON PLANS. NOTE: NEED
 PRODUCT APPROVAL THAT IS DESIGNED TO RECEIVE TILE AS
 SPECIFIED ON PLANS. CLEARLY IDENTIFY SPECIFIC ASSEMBLY
 TO BE USED. IF SELECTED ASSEMBLY DOESN'T MEET THE
 DESIGN PRESSURES FOR ALL ZONES, THEN SIGNED AND SEALED
 RAS 117 CALCULATIONS WILL BE REQUIRED.
 RESPONSE: KEMPEROL MEMBRANE WATERPROOFING SYSTEM
 SUBMITTED IS FOR CONCRETE DECKS. THIS IS A WOOD DECK.
 PROVIDE PROPER PRODUCT APPROVAL. AND IDENTIFY SELECTED
 ASSEMBLY AS REQUESTED ABOVE.
  
 11- DESIGNER OF RECORD TO APPROVE ABOVE PRODUCT
 APPROVALS AS REQUIRED BY SEC. 107.3.4.1 CITY
 AMENDMENTS.
  
 NOTE: PROVIDE MANUFACTURER'S CUT SHEETS FOR SECOND
 FLOOR EGRESS WINDOWS TO VERIFY COMPLIANCE WITH ALL MIN.
 OPENING REQUIREMENTS. SOME WINDOWS DEPENDING ON THE
 SPECIFIC MODEL DON'T COMPLY WITH ALL THE REQUIREMENTS.
 THIS WILL AVOID CONFLICTS/DELAYS.
  
  
 *** PLEASE PROVIDE RESPONSE LETTER ADDRESING EACH
 COMMENT TO HELP EXPEDITE THE REVIEW PROCESS.
 **** PLEASE INSERT ANY REVISED DRAWING AND REMOVE OLD
 DRAWING. DON'T STAPLE OLD DRAWINGS. SUBMIT ALL DRAWINGS
 FOR REFERENCE.
  
  