| Plan Review Notes For Permit 17100284 |
| Permit Number |
17100284 |
|
| Review Stop |
R |
| Sequence Number |
1 |
|
| Notes |
| Date |
Text |
| 2017-11-08 17:53:55 | 1- IT IS NOT CLEAR WHAT TYPE OF ROOFING MATERIAL IS | | | GOING TO BE USED. PLANS CALL FOR METAL ROOFING, WHILE | | | PRODUCT APPROVAL SUBMITTED IS FOR SHINGLES. REVISE AS | | | REQUIRED TO MATCH. SEC. 107.2.1 CITY AMENDMENTS. | | | | | | 2- PROVIDE PRODUCT APPROVAL (2 COPIES) AS REQUIRED BY | | | FAC 61G20-3.001 FOR: | | | A) ROOF MATERIAL TO BE USED. COORDINATE WITH ITEM #1 | | | ABOVE TO AVOID CONFLICTS/DELAYS. | | | | | | B) IF USING SHINGLES, THEN THE RIDGE CAP SHINGLES NOA | | | 13-0306.08 SUBMITTED EXPIRED ON 10/17/17. PROVIDE | | | CURRENT NOA. | | | | | | C) BALCONY UNDERLAYMENT SPECIFIED ON PLANS. NOTE: NEED | | | PRODUCT APPROVAL THAT IS DESIGNED TO RECEIVE TILE AS | | | SPECIFIED ON PLANS. CLEARLY IDENTIFY SPECIFIC ASSEMBLY | | | TO BE USED. IF SELECTED ASSEMBLY DOESN'T MEET THE | | | DESIGN PRESSURES FOR ALL ZONES, THEN SIGNED AND SEALED | | | RAS 117 CALCULATIONS WILL BE REQUIRED. | | | | | | 3- DESIGNER OF RECORD TO APPROVE ABOVE PRODUCT | | | APPROVALS AS REQUIRED BY SEC. 107.3.4.1 CITY | | | AMENDMENTS. | | | |
|