| Plan Review Notes For Permit 17100284 |
| Permit Number |
17100284 |
|
| Review Stop |
P |
| Sequence Number |
1 |
|
| Notes |
| Date |
Text |
| 2017-11-03 10:38:18 | 1ST REVIEW: FBC 2014 5TH EDITION | | | | | | PLUMBING COMMENTS: | | | | | | 1. SHT P-1 NOTE #15 AIR CHAMBERS ARE NOT CODE COMPLIANT | | | YOU SHALL USE WATER HAMMER ARRESTORS SHALL CONFORM TO | | | ASSE 1010. PER FBC ACC P2903.5 | | | | | | 2. THE WATER CLOSET IN BATHROOM 1 IS NOTE VENTED, THE | | | TUB, WATER CLOSET AND LAVATORY SHOULD BE VENTED | | | TOGETHER AS A WET VENT AND THEN CONNECTED TO BUILDING | | | DRAIN. PER FBC RES P3108.1 | | | | | | 3. PLEASE SHOW LOCATION AND TYPE OF WATER HEATER. PER | | | WPB AMEND TO FBC 107.2.1 | | | | | | 4. PROVIDE DETAIL FOR WATER HEATER PIPING. PER WPB | | | AMEND TO FBC 107.2.1 | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT | | | CORRECTED PAGES INTO TO SUBMITTAL AND REMOVE OR VOID | | | THE PREVIOUSLY REVIEWED SHEETS. | | | | | | GEORGE JOHNSON | | | PLUMBING PLANS EXAMINER | | | CITY OF WEST PALM BEACH | | | 561-805-6711 | | | [email protected] | | | |
|