| 2017-10-18 12:53:23 | ****CORRECTIONS**** | | | **SENT EMAIL TO [email protected] ON 10/18/2017 | | | ADVISING THAT THEY NEED TO APPLY FOR TENT PERMIT, SENT | | | EMAIL ON 10/23/17 ADVISING THAT EVENT APPLICATION HAS | | | COMMENTS WITH INSTRUCTIONS ON HOW TO SEE COMMENTS; | | | SPOKE WITH APPLICANT ON TELEPHONE** | | | | | | SAMANTHA HILL | | | BUILDING PLANS EXAMINER | | | [email protected] | | | 561-805-6724 | | | | | | FBC = FLORIDA BUILDING CODE, 5TH EDITION (2014) | | | FBC B = FBC BUILDING | | | FBC EB = FBC EXISTING BUILDING | | | FBC A = FBC ACCESSIBILITY | | | FBC EC = FBC ENERGY CONSERVATION | | | | | | 1. FBC B 3103, REVISE PLAN TO INCLUDE THE FOLLOWING | | | INFORMATION: | | | | | | OCCUPANCY CLASSIFICATION FBC B CHAPTER 3 | | | OCCUPANT LOAD FBC B 1004 | | | MEANS OF EGRESS (WIDTH OF AISLES, EXITS) | | | INFORMATION REGARDING EXITS - REVISE PLAN TO INDICATE | | | WHETHER THESE ARE DOORS OR GATES, AND REVISE PLAN TO | | | NOTE PANIC BAR/FIRE EXIT HARDWARE REQUIREMENT ON ALL | | | DOORS AND GATES FBC B 1008.1.10. | | | A NUMBER OF UNIDENTIFIED RECTANGLES ARE DEPICTED; | | | REVISE PLAN TO INDENTIFY. ADDITIONAL INFORMATION MAY BE | | | REQUIRED | | | |
|