| 2017-10-03 10:39:22 | ****PLAN REVIEW COMMENTS**** |
| | |
| | ART LANGE - BUILDING INSPECTOR |
| | 561-805-6667 [email protected] |
| | FBC FLORIDA BUILDING CODE 2014 5TH EDITION/ FRC FLORIDA |
| | RESIDENTIAL CODE 2015 5TH EDITION |
| | |
| | 1. PROVIDE THE SIZE OF THE DECK AND INCLUDE THE JOIST |
| | SPANS, TYPE OF JOIST HANGER AND POST ATTACHMENT USED. |
| | SEE ALSO ZONING COMMENTS FOR DECK LOCATION. |
| | INCLUDE A LEDGER BOARD ATTACHMENT DETAIL. FBC 107.3.5 |
| | MINIMUM PLAN REVIEW CRITERIA FOR BUILDINGS. |
| | |
| | 2. SINCE GUARDS ARE USED SHOW HOW THEY WILL COMPLY WITH |
| | THE OPENING LIMITATIONS OF R312.1.3 |
| | |
| | 3. PROVIDE ADDITION INFORMATION FOR THE STAIRS. WIDTH |
| | AND HOW CONSTRUCTED. |
| | |
| | SHOW HOW THEY WILL COMPLY WITH THE SECTIONS OF R311.7 |
| | FOR TREAD AND RISERS. |
| | |
| | SHOW ALSO THE LANDING SIZE. R311.7.6 |
| | |
| | SHOW HAND RAIL HEIGHT AND LOCATION. R311.7.8 |
| | |
| | 4. PLEASE REVISE PERMIT VALUE TO INCLUDE THE NEW SCOPE |
| | OF WORK. |
| | |
| | 109.3 BUILDING PERMIT VALUATIONS. IF, IN THE OPINION OF |
| | THE BUILDING OFFICIAL, THE CLAIMED VALUATION OF |
| | BUILDING, ALTERATION, STRUCTURE, ELECTRICAL, GAS, |
| | MECHANICAL OR PLUMBING SYSTEMS APPEARS TO BE |
| | UNDERESTIMATED ON THE APPLICATION, THE PERMIT SHALL BE |
| | DENIED, UNLESS THE APPLICANT CAN SHOW DETAILED, |
| | QUANTITY ESTIMATES, AND/OR BONA FIDE SIGNED CONTRACTS |
| | (EXCLUDING LAND VALUE) TO MEET THE APPROVAL OF THE |
| | BUILDING OFFICIAL. FOR PERMITTING PURPOSES, VALUATION |
| | OF BUILDINGS AND SYSTEMS SHALL BE TOTAL REPLACEMENT |
| | VALUE TO INCLUDE STRUCTURAL, ELECTRIC, PLUMBING, |
| | MECHANICAL, INTERIOR FINISH, RELATIVE SITE WORK, |
| | ARCHITECTURAL AND DESIGN FEES, MARKETING COSTS, |
| | OVERHEAD AND PROFIT; EXCLUDING ONLY LAND VALUE. |
| | VALUATION REFERENCES MAY INCLUDE THE LATEST PUBLISHED |
| | DATA OF NATIONAL CONSTRUCTION COST ANALYSIS SERVICES |
| | (MARSHALL-SWIFT, MEANS, ETC.), AS PUBLISHED BY |
| | INTERNATIONAL CODE CONGRESS. |
| | FINAL BUILDING PERMIT VALUATION SHALL BE SET BY THE |
| | BUILDING OFFICIAL. |
| | YOU MAY PROVIDE A COPY OF THE CONTRACT SIGNED BY THE |
| | OWNER OR A LIST OF LABOR, MATERIALS AND EQUIPMENT |
| | RENTAL TO VERIFY VALUE. |
| | |