| Plan Review Notes For Permit 17090360 |
| Permit Number |
17090360 |
|
| Review Stop |
B |
| Sequence Number |
1 |
|
| Notes |
| Date |
Text |
| 2017-09-22 17:57:59 | RE-ROOF BUILDING REVIEW COMMENTS. | | | CODE: FBC 5TH EDITION (2014). | | | | | | 1- FLAT ROOF FLORIDA PRODUCT APPROVAL FL2533-R18 | | | SUBMITTED: THE DESIGN PRESSURES OF SELECTED ASSEMBLY | | | W-77 DON'T MEET THE DESIGN PRESSURES FOR ROOF ZONE #3. | | | NEED TO PROVIDE SIGNED AND SEALED RAS 117 CALCULATIONS | | | (2 COPIES) AS REQUIRED BY NOTE #8 OF FLORIDA PRODUCT | | | APPROVAL SUBMITTED. NEED THE CALCULATIONS TO MEET ALL | | | THE DESIGN PRESSURES OF SEC. 1609.1 FBC 5TH EDITION. | | | NOTE: THIS BUILDING IS LOCATED IN EXPOSURE "D". | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT | | | JULIO GOMEZ | | | COMMERCIAL COMBINATION PLANS EXAMINER | | | DEVELOPMENT SERVICES DEPARTMENT | | | BUILDING DIVISION | | | (561)805-6712 | | | [email protected] | | | | | | | | | |
|