| 2017-11-13 11:36:12 | 2ND REVIEW: FBC 2014 5TH EDITION |
| | |
| | PLUMBING COMMENTS: |
| | |
| | 1. SHT. P.1.3.00C AND P.3.1.00C |
| | A) PLEASE IDENTIFY THE DRAIN LOCATED AT REFRIGERATOR. |
| | PER WPB AMEND TO FBC 107.2.1 |
| | B) IF THE DRAIN AT THE REFRIGERATOR IS FOR THE ICE |
| | MACHINE A TRAP PRIMER VALVE IS REQUIRED ON THE P-TRAP. |
| | PER FBC RES P3201.2 |
| | C) THE FITTING FOR THE BRANCH DRAIN AT THE KITCHEN SINK |
| | AND THE DRAIN AT THE REFRIGERATOR ARE SHOWN WITH THE |
| | WRONG DIRECTION OF FLOW PLEASE CLARIFY. PER FBC RES |
| | P3005.1 |
| | D) HORIZONTAL DRY VENTS ARE NOT ALLOWED, THE VENTS |
| | SHOWN ON THE DRAIN AT THE REFRIGERATOR AND THE MASTER |
| | BATH WATER CLOSET ARE NOT CODE COMPLIANT THEY SHALL |
| | COMPLY WITH FBC RES P3104.3 VENT CONNECTION TO DRAINAGE |
| | SYSTEM. |
| | A DRY VENT CONNECTING TO A HORIZONTAL DRAIN SHALL |
| | CONNECT ABOVE THE CENTERLINE OF THE HORIZONTAL DRAIN |
| | PIPE. |
| | P3104.4 VERTICAL RISE OF VENT. |
| | A DRY VENT SHALL RISE VERTICALLY TO NOT LESS THAN 6 |
| | INCHES (152 MM) ABOVE THE FLOOD LEVEL RIM OF THE |
| | HIGHEST TRAP OR TRAPPED FIXTURE BEING VENTED. |
| | |
| | 2. PLEASE PLACE NOTE ON PLAN THE MASTER BATH TUB VALVE |
| | SHALL COMPLY WITH FBC RES P2713.3 BATHTUB AND WHIRLPOOL |
| | BATHTUB VALVES. |
| | HOT WATER SUPPLIED TO BATHTUBS AND WHIRLPOOL BATHTUBS |
| | SHALL BE LIMITED TO A TEMPERATURE OF NOT GREATER THAN |
| | 120?F (49?C) BY A WATERTEMPERATURE LIMITING DEVICE THAT |
| | CONFORMS TO ASSE 1070 OR CSA B125.3, EXCEPT WHERE SUCH |
| | PROTECTION IS OTHERWISE PROVIDED BY A COMBINATION |
| | TUB/SHOWER VALVE IN ACCORDANCE WITH SECTION P2708.3. |
| | |
| | |
| | |
| | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED |
| | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. |
| | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE |
| | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY |
| | RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT |
| | CORRECTED PAGES INTO TO SUBMITTAL AND REMOVE OR VOID |
| | THE PREVIOUSLY REVIEWED SHEETS. |
| | |
| | GEORGE JOHNSON |
| | PLUMBING PLANS EXAMINER |
| | CITY OF WEST PALM BEACH |
| | 561-805-6711 |
| | [email protected] |
| | |