2017-09-20 10:24:53BUILDING PLAN REVIEW
 2014 FLORIDA BUILDING CODE W/2010 WEST PALM BEACH
 AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1
 ADMINISTRATION
  
 CHRISTOPHER S. THROOP, C.B.O.
 PLANS EXAMINER, PX3169
 CONSTRUCTION SERVICES DIVISION
 TEL: 561-805-6726
 FAX: 561-805-6676
  
 1ST REVIEW
 RESULTS: DENIED
 ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT
  
 NOTE: THIS IS A SFR UNIT BEING USED AS A SALES CENTER.
 BUILDING OFFICIAL CHANGED OCCUPANCY CLASSIFICATION FROM
 RESIDENTIAL TO BUSINESS.
 THIS REVIEW IS BASED ON THE 2014 FLORIDA BUILDING CODE
 AND THE 2014 FLORIDA ACCESSIBILITY CODE.
 PLEASE REMOVE ALL REFERENCES TO THE 2014 FLORIDA
 RESIDENTIAL CODE FROM PLANS.
 PLEASE NOTE ANY RESIDENTIAL FEATURE ON PLANS AS FUTURE
 USE.
  
 1. PROVIDE ADDRESS AND RECORDED PLATT.
 2. PROVIDE SITE PLAN - SHOW ACCESSIBLE PARKING AND
 ACCESSIBLE ROUTE.
 3. VALUE - BASED ON THE INTERNATIONAL CODE COUNCIL
 BUILDING VALUATION DATA, THE VALUE WILL BE INCREASED
 FROM $139,160.00 TO $270,745.00 BASED ON 2,331 SQ. FT.
 UNDER AIR X $116.15/SQ. FT.
 4. ENERGY SUBMITTAL NEEDS TO BE SITE SPECIFIC. PROVIDE
 ADDRESS.
 5. NOA 14-0908.18 FOR THE FIXED WINDOWS HAS EXPIRED.
 PROVIDE CURRENT NOA.
 6. ADA POWDER ROOM TURNING RADIUS DOES NOT COMPLY WITH
 ACCESSIBILITY CODE 304.3.1, 603.2.1 & 603.2.3.
 7. PROVIDE MANUFACTURERS INSTALLATION INSTRUCTIONS FOR
 SUMMER KITCHEN BBQ.
 8. NO KITCHEN IS SHOWN ON ARCHITECTURAL DRAWINGS.
 IDENTIFY KITCHEN ON MEP PLANS AS FUTURE USE.
 9. PROVIDE DOOR BUCK DETAIL FOR OHD, SGD & EXT. DOORS.
 10. REVISE PLANS TO INDICATE GOVERNING CODES AS 2014
 FBC. RESIDENTIAL CODE DOES NOT APPLY. IDENTIFY
 RESIDENTIAL ELEMENTS ON PLANS AS FUTURE USE.
  
 FBC 107.3.5 MINIMUM PLAN REVIEW CRITERIA FOR BUILDINGS.
 THE EXAMINATION OF THE DOCUMENTS BY THE BUILDING
 OFFICIAL SHALL INCLUDE THE FOLLOWING MINIMUM CRITERIA
 AND DOCUMENTS: A FLOOR PLAN; SITE PLAN; FOUNDATION
 PLAN; FLOOR/ROOF FRAMING PLAN OR TRUSS LAYOUT; ALL
 FENESTRATION PENETRATIONS; FLASHING; AND ROUGH OPENING
 DIMENSIONS; AND ALL EXTERIOR ELEVATIONS:
  
 CITY OF WPB CHPT. 1 - VALUE
 109.3 BUILDING PERMIT VALUATIONS. IF, IN THE OPINION OF
 THE BUILDING OFFICIAL, THE CLAIMED VALUATION OF
 BUILDING, ALTERATION, STRUCTURE, ELECTRICAL, GAS,
 MECHANICAL OR PLUMBING SYSTEMS APPEARS TO BE
 UNDERESTIMATED ON THE APPLICATION, THE PERMIT SHALL BE
 DENIED, UNLESS THE APPLICANT CAN SHOW DETAILED,
 QUANTITY ESTIMATES, AND/OR BONA FIDE SIGNED CONTRACTS
 (EXCLUDING LAND VALUE) TO MEET THE APPROVAL OF THE
 BUILDING OFFICIAL. FOR PERMITTING PURPOSES, VALUATION
 OF BUILDINGS AND SYSTEMS SHALL BE TOTAL REPLACEMENT
 VALUE TO INCLUDE STRUCTURAL, ELECTRIC, PLUMBING,
 MECHANICAL, INTERIOR FINISH, RELATIVE SITE WORK,
 ARCHITECTURAL AND DESIGN FEES, MARKETING COSTS,
 OVERHEAD AND PROFIT; EXCLUDING ONLY LAND VALUE.
 VALUATION REFERENCES MAY INCLUDE THE LATEST PUBLISHED
 DATA OF NATIONAL CONSTRUCTION COST ANALYSIS SERVICES
 (MARSHALL-SWIFT, MEANS, ETC.), AS PUBLISHED BY
 INTERNATIONAL CODE CONGRESS.
 FINAL BUILDING PERMIT VALUATION SHALL BE SET BY THE
 BUILDING OFFICIAL.
  
 FBC 107.3.4 - PROVIDE PRODUCT APPROVALS FOR THOSE
 PRODUCTS WHICH ARE REGULATED BY FAC RULE 9N-3 REVIEWED
 AND APPROVED IN WRITING BY THE DESIGNER OF RECORD.
 SPECIFICALLY, PROVIDE ROOFING, WINDOW, AND DOOR
 SUBMITTALS.
  
 304.3.1 CIRCULAR SPACE.
 THE TURNING SPACE SHALL BE A SPACE OF 60 INCHES (1525
 MM) DIAMETER MINIMUM. THE SPACE SHALL BE PERMITTED TO
 INCLUDE KNEE AND TOE CLEARANCE COMPLYING WITH 306
 603.2.1 TURNING SPACE.
 TURNING SPACE COMPLYING WITH 304 SHALL BE PROVIDED
 WITHIN THE ROOM.
 603.2.2 OVERLAP.
 REQUIRED CLEAR FLOOR SPACES, CLEARANCE AT FIXTURES, AND
 TURNING SPACE SHALL BE PERMITTED TO OVERLAP.
 603.2.3 DOOR SWING.
 DOORS SHALL NOT SWING INTO THE CLEAR FLOOR SPACE OR
 CLEARANCE REQUIRED FOR ANY FIXTURE. DOORS SHALL BE
 PERMITTED TO SWING INTO THE REQUIRED TURNING SPACE.
  
 FBC 107.2.1 INFORMATION ON CONSTRUCTION DOCUMENTS.
 CONSTRUCTION DOCUMENTS SHALL BE DIMENSIONED AND DRAWN
 UPON SUITABLE MATERIAL. CONSTRUCTION DOCUMENTS SHALL BE
 OF SUFFICIENT CLARITY TO INDICATE THE LOCATION, NATURE
 AND EXTENT OF THE WORK PROPOSED AND SHOW IN DETAIL THAT
 IT WILL CONFORM TO THE PROVISIONS OF THIS CODE AND
 RELEVANT LAWS, ORDINANCES, RULES AND REGULATIONS, AS
 DETERMINED BY THE BUILDING OFFICIAL.
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT
 CORRECTED PAGES INTO SUBMITTAL AND LEAVE THE PREVIOUSLY
 REVIEWED SHEETS DETACHED AND MARK VOID.
  
  
  
  
  