| Date |
Text |
| 2017-11-03 18:47:34 | NEW GUEST HOUSE (R3) MECHANICAL REVIEW COMMENTS. |
| | CODE: FBC 5TH EDITION (2014). |
| | |
| | |
| | NOTE: |
| | MECHANICAL REVIEW MAY BE APPROVED WITH PROVISO. PROVISO |
| | MEANS THAT CONTRACTOR WILL PROVIDE REQUIRED INFORMATION |
| | AFTER THE PERMIT IS ISSUED BUT BEFORE INSPECTIONS TO |
| | AVOID CONFLICTS/DELAYS. REVISION FEES WILL APPLY. |
| | CONTRACTOR TO ADVICE IF PROVISO OPTION IS PREFERRED AT |
| | THIS TIME. |
| | |
| | 1- EQUIPMENT SIZING CALCULATIONS ARE DONE BASED ON THE |
| | INFORMATION SUBMITTED IN THE ENERGY CALCULATIONS. |
| | ENERGY CALCULATIONS NEED TO BE REVISED. SEE BUILDING |
| | REVIEW COMMENTS BELOW. REVISE THE EQUIPMENT SIZING |
| | CALCULATIONS ONCE THE ENERGY CALCULATIONS ARE REVISED. |
| | SEC. R403.6.1 FBC-ENERGY CONSERVATION, 5TH EDITION |
| | (2014). |
| | |
| | |
| | BUILDING REVIEW COMMENTS: |
| | 1- ENERGY CALCULATIONS FORM R405-2014 SUBMITTED: |
| | A) OWNER OR LEGALLY DESIGNATED AGENT TO CERTIFY AT THE |
| | BOTTOM OF THE FORM AS REQUIRED BY SEC. R103.1.1.2 |
| | FBC-ENERGY CONSERVATION, 5TH EDITION (2014). |
| | |
| | B) PROVIDE COMPLETE INFORMATION ON TOP OF FORM, |
| | INCLUDING THE OWNER'S NAME AND BUILDER'S NAME. SEC. |
| | R101.5.1.1.2 FBC-ENERGY CONSERVATION. |
| | |
| | C) CONCRETE BLOCK WALL INSULATION R-VALUE SPECIFIED ON |
| | ITEM #9 DOESN'T MATCH ARCHITECT'S PLANS. REVISE AS |
| | REQUIRED TO MATCH. SEC. R103.2 FBC-ENERGY CONSERVATION. |
| | |
| | D) CEILING INSULATION R-VALUE AND AREA SPECIFIED ON |
| | ITEM #10 DOESN'T MATCH PLANS. REVISE AS REQUIRED TO |
| | MATCH. SEC. R103.2 FBC-ENERGY CONSERVATION. |
| | |
| | E) PROVIDE COMPLETE INSPECTION CHECKLIST DOCUMENTING |
| | THE BUILDING COMPONENT CHARACTERISTICS OF THE PROPOSED |
| | DESIGN AS REQUIRED BY SEC. R405.4.2 FBC-ENERGY |
| | CONSERVATION. |
| | |
| | F) PROVIDE THE NAME OF THE PERSON COMPLETING THE |
| | COMPLIANCE REPORT AS REQUIRED BY SEC. R405.4.2 |
| | FBC-ENERGY CONSERVATION. |
| | |
| | G) THE ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD |
| | SUBMITTED NEEDS TO BE COMPLETED BY THE BUILDER AS |
| | REQUIRED BY SEC. R405.4.3 FBC-ENERGY CONSERVATION. |
| | |
| | H) THE "SPACES" INFORMATION ON 2 OF 4 SPECIFIES THAT |
| | THERE IS A KITCHEN. ACCORDING TO PLANS SUBMITTED THERE |
| | IS NOT KITCHEN IN THE GUEST HOUSE. THERE IS SUPPOSED TO |
| | BE NO COOKING. NOTE: ZONING DOESN'T ALLOW A KITCHEN FOR |
| | THE GUEST HOUSE. REVISE ENERGY CALCULATIONS AS |
| | REQUIRED. SEC. R103.2 FBC-ENERGY CONSERVATION. |
| | |
| | I) THE ROOF TYPE AND MATERIALS SPECIFIED ON PAGE 2 OF 4 |
| | DON'T MATCH PLANS. SEE PLANS AND REVISE AS REQUIRED. |
| | SEC. R103.2 FBC-ENERGY CONSERVATION. |
| | |
| | |
| | |
| | |
| | ****PLEASE PROVIDE RESPONSE LETTER TO EXPEDITE THE |
| | REVIEW PROCESS. |
| | |
| | IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT |
| | JULIO GOMEZ |
| | COMMERCIAL COMBINATION PLANS EXAMINER |
| | DEVELOPMENT SERVICES DEPARTMENT |
| | BUILDING DIVISION |
| | (561)805-6712 |
| | [email protected] |
| | |