Plan Review Notes
Plan Review Notes For Permit 17081050
Permit Number 17081050
Review Stop FIRE
Sequence Number 1
Notes
Date Text
2017-08-25 09:56:23THIS PLAN WAS REVIEWED AND FAILED BY PETER LEDUC, FIRE
 MARSHAL, WITH THE FOLLOWING COMMENTS:
  
  
 1) THIS SUBMITTAL DOES NOT INCLUDE DETAILS OR EQUIPMENT
 THAT IS TIED IN TO A DRY DOUBLE ACTION SPRINKLER
 SYSTEM.
  
 PER NFPA 13,
  
 8.15.10 ELECTRICAL EQUIPMENT.
 8.15.10.1 UNLESS THE REQUIREMENTS OF 8.15.10.3 ARE MET,
 SPRINKLER PROTECTION SHALL BE REQUIRED IN ELECTRICAL
 EQUIPMENT ROOMS.
 8.15.10.2 HOODS OR SHIELDS INSTALLED TO PROTECT
 IMPORTANT ELECTRICAL EQUIPMENT FROM SPRINKLER DISCHARGE
 SHALL BE NONCOMBUSTIBLE.
 8.15.10.3 SPRINKLERS SHALL NOT BE REQUIRED IN
 ELECTRICAL EQUIPMENT ROOMS WHERE ALL OF THE FOLLOWING
 CONDITIONS ARE MET:
 (1) THE ROOM IS DEDICATED TO ELECTRICAL EQUIPMENT ONLY.
 (2) ONLY DRY-TYPE ELECTRICAL EQUIPMENT IS USED.
 (3) EQUIPMENT IS INSTALLED IN A 2-HOUR FIRE-RATED
 ENCLOSURE INCLUDING PROTECTION FOR PENETRATIONS.
 (4) NO COMBUSTIBLE STORAGE IS PERMITTED TO BE STORED IN
 THE ROOM.
  
  
 THE CONDITIONS OF 8.15.10.3 HAVE NOT BEEN MET.
 SPRINKLER PERMIT 17060221 HAS BEEN DENIED BASED ON THE
 SAME COMMENT.
  
 PLEASE COORDINATE WITH THE FIRE SPRINKLER CONTRACTOR
 NAD PROVIDED FOR THE REQUIRED SYSTEM PROTECTION.
  
  
  
  
 2) WHEN RESUBMITTING, PLEASE PROVIDE PLAN SHEET
 REVISION CLOUDS OR NUMBERED NARRATIVE RESPONSES TO THE
 ABOVE.
  
  
  
 3) ADDITIONAL COMMENTS MAY BE PROVIDED ON THE
 RE-SUBMITTAL OF THE ABOVE.
  
  
  
 PETER LEDUC
 FIRE MARSHAL
 561-804-4709
 [email protected]
  
  
  
  
  


Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved