2017-08-29 18:03:59****CORRECTIONS****
  
 SAMANTHA HILL
 BUILDING PLANS EXAMINER
 [email protected]
 561-805-6724
  
 FBC = FLORIDA BUILDING CODE, 5TH EDITION (2014)
 FBC B = FBC BUILDING
 FBC EB = FBC EXISTING BUILDING
 FBC A = FBC ACCESSIBILITY
 FBC EC = FBC ENERGY CONSERVATION
  
 1. CALCULATIONS AND PLANS ARE FOR THE SIX STORY
 BUILDING. THE ADDRESS ON THE APPLICATION, 2221, DOES
 NOT CORRELATE WITH ANY OF THE BUILDING PERMIT
 APPLICATIONS (2201, 2171, 2191 N AUSTRALIAN AVE). THE
 SITE PLAN SHOWS A SIX STORY PROPOSED BUILDING AS 2221 N
 AUSTRALIAN AVE. ON THE SITE PLAN, WHERE IS 2191 N
 AUSTRALIAN AVE? IS ANOTHER SIX STORY PROPOSED? FBC 107,
 SCOPE NOT CLEAR.
  
 SITE PLAN SHOWS "EXISTING" SIX STORY BUILDINGS WHICH DO
 NOT APPEAR ON AERIALS, AND NO EVIDENCE OF PERMITS FOR
 RECENT CONSTRUCTION OF SIX STORY BUILDINGS ON THIS
 PARCEL. REVISE SITE PLAN (ON ALL AFFECTED PERMITS) OR
 CLARIFY.
  
 2. A COMPLETE SET OF PLANS WAS SUBMITTED. REMOVE
 UNNECESSARY SHEETS, FBC 107. SEE REVIEW UNDER 17081012
 FOR DOCUMENTS TYPICALLY REQUIRED FOR FOUNDATION PERMIT.
  
 3. CALCULATIONS INCLUDE OUTDATED CODE REFERENCES,
 REVISE, FBC CH 35 (ASCE7-05, IBC 2009, ACI 2008, ETC.).
  
 4. IF THIS IS A PROPOSED SIX STORY, THIS IS A THRESHOLD
 BUILDING AND THE COMMENTS FOR 17081012 ARE APPLICABLE.
  
 SCOPE NOT CLEAR; COMPLETE REVIEW CANNOT BE DONE AT THIS
 TIME.
  
  