Plan Review Notes
Plan Review Notes For Permit 17080671
Permit Number 17080671
Review Stop B
Sequence Number 1
Notes
Date Text
2017-10-03 07:52:36****CORRECTIONS****
  
 SAMANTHA HILL
 BUILDING PLANS EXAMINER
 [email protected]
 561-805-6724
  
 FBC = FLORIDA BUILDING CODE, 5TH EDITION (2014)
 FBC B = FBC BUILDING
 FBC EB = FBC EXISTING BUILDING
 FBC A = FBC ACCESSIBILITY
 FBC EC = FBC ENERGY CONSERVATION
  
 1. FBC A 404.2.4, SEE ALSO FIGURE 404.2.4.1(A), 18"
 MANEUVERING CLEARANCE REQUIRED FOR DOOR 1. SEE ALSO FBC
 A 203.9 REGARDING EMPLOYEE WORK AREAS. IF ARCHITECT
 FEELS THAT THIS DOOR IS EXEMPT, PLEASE SEND RATIONALE
 VIA EMAIL PRIOR TO RESUBMITTING. PLAN WILL BE REQUIRED
 TO BE REVISED TO INCLUDE RATIONALE IF THE 18"
 MANEUVERING CLEARANCE IS NOT PROVIDED.
  
  