Plan Review Notes
Plan Review Notes For Permit 17080615
Permit Number 17080615
Review Stop B
Sequence Number 2
Notes
Date Text
2017-11-07 07:02:49BUILDING PLAN REVIEW
 2014 FLORIDA BUILDING CODE W/2010 WEST PALM BEACH
 AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1
 ADMINISTRATION
  
 CHRISTOPHER S. THROOP, C.B.O.
 PLANS EXAMINER, PX3169
 CONSTRUCTION SERVICES DIVISION
 TEL: 561-805-6726
 FAX: 561-805-6676
  
 2ND REVIEW
 RESULTS: DENIED
 ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT
  
 1. SOW ON APPLICATION IS TO RE-STUCCO EXTERIOR OF
 HOUSE.
 2. PROPERTY RECORDS INDICATE HOUSE HAS WOOD SIDING.
 3. PROVIDE ELEVATION DETAIL OF WALL ASSEMBLY. INCLUDE
 SPACING OF EXTERIOR WALL STUDS, HOUSE WRAP, PAPER
 BACKED WIRE LATH AND STUCCO. STUCCO TO BE APPLIED PER
 FBCR703.
 4. VALUE APPEARS LOW.
  
 R703.1
 EXTERIOR WALLS SHALL PROVIDE THE BUILDING WITH A
 WEATHER-RESISTANT EXTERIOR WALL ENVELOPE. THE EXTERIOR
 WALL ENVELOPE SHALL INCLUDE FLASHING AS DESCRIBED IN
 SECTION R703.8.
 R703.1.1 WATER RESISTANCE.
 THE EXTERIOR WALL ENVELOPE SHALL BE DESIGNED AND
 CONSTRUCTED IN A MANNER THAT PREVENTS THE ACCUMULATION
 OF WATER WITHIN THE WALL ASSEMBLY BY PROVIDING A
 WATER-RESISTANT BARRIER BEHIND THE EXTERIOR VENEER AS
 REQUIRED BY SECTION R703.2 AND A MEANS OF DRAINING TO
 THE EXTERIOR WATER THAT ENTERS THE ASSEMBLY. PROTECTION
 AGAINST CONDENSATION IN THE EXTERIOR WALL ASSEMBLY
 SHALL BE PROVIDED IN ACCORDANCE WITH SECTION R702.7 OF
 THIS CODE.
 ? ALL EXTERIOR WALLS, WALL COVERINGS AND SOFFITS SHALL
 BE CAPABLE OF RESISTING THE DESIGN PRESSURES SPECIFIED
 IN TABLE R301.2(2) FOR WALLS.
 R703.2 WATER-RESISTIVE BARRIER.
 ONE LAYER OF NO. 15 ASPHALT FELT, FREE FROM HOLES AND
 BREAKS, COMPLYING WITH ASTM D 226 FOR TYPE 1 FELT OR
 OTHER APPROVED WATER-RESISTIVE BARRIER SHALL BE APPLIED
 OVER STUDS OR SHEATHING OF ALL EXTERIOR WALLS. SUCH
 FELT OR MATERIAL SHALL BE APPLIED HORIZONTALLY, WITH
 THE UPPER LAYER LAPPED OVER THE LOWER LAYER NOT LESS
 THAN 2 INCHES (51 MM). WHERE JOINTS OCCUR, FELT SHALL
 BE LAPPED NOT LESS THAN 6 INCHES (152 MM). THE FELT OR
 OTHER APPROVED MATERIAL SHALL BE CONTINUOUS TO THE TOP
 OF WALLS AND TERMINATED AT PENETRATIONS AND BUILDING
 APPENDAGES IN A MANNER TO MEET THE REQUIREMENTS OF THE
 EXTERIOR WALL ENVELOPE AS DESCRIBED IN SECTION R703.1
 ? R703.6 EXTERIOR PLASTER.
 INSTALLATION OF THESE MATERIALS SHALL BE IN COMPLIANCE
 WITH ASTM C 926 AND ASTM C 1063 AND THE PROVISIONS OF
 THIS CODE.
 R703.6.1 LATH.
 ALL LATH AND LATH ATTACHMENTS SHALL BE OF
 CORROSION-RESISTANT MATERIALS. EXPANDED METAL OR WOVEN
 WIRE LATH SHALL BE ATTACHED WITH 11/2-INCH-LONG (38
 MM), 11 GAGE NAILS HAVING A 7/16-INCH (11.1 MM) HEAD,
 OR 7/8-INCHLONG (22.2 MM), 16 GAGE STAPLES, SPACED AT
 NO MORE THAN 6 INCHES (152 MM), OR AS OTHERWISE
 APPROVED.
 R703.6.2 PLASTER.
 PLASTERING WITH PORTLAND CEMENT PLASTER SHALL BE NOT
 LESS THAN THREE COATS WHEN APPLIED OVER METAL LATH OR
 WIRE LATH AND SHALL BE NOT LESS THAN TWO COATS WHEN
 APPLIED OVER MASONRY, CONCRETE, PRESSURE-PRESERVATIVE
 TREATED WOOD OR DECAY-RESISTANT WOOD AS SPECIFIED IN
 SECTION R317.1 OR GYPSUM BACKING. IF THE PLASTER
 SURFACE IS COMPLETELY COVERED BY VENEER OR OTHER FACING
 MATERIAL OR IS COMPLETELY CONCEALED, PLASTER
 APPLICATION NEED BE ONLY TWO COATS, PROVIDED THE TOTAL
 THICKNESS IS AS SET FORTH IN TABLE R702.1(1).
 ON WOOD-FRAME CONSTRUCTION WITH AN ON-GRADE FLOOR SLAB
 SYSTEM, EXTERIOR PLASTER SHALL BE APPLIED TO COVER, BUT
 NOT EXTEND BELOW, LATH, PAPER AND SCREED
 R703.6.3 WATER-RESISTIVE BARRIERS.
 WATER-RESISTIVE BARRIERS SHALL BE INSTALLED AS REQUIRED
 IN SECTION R703.2 AND, WHERE APPLIED OVER WOOD-BASED
 SHEATHING, SHALL INCLUDE A WATER-RESISTIVE
 VAPOR-PERMEABLE BARRIER WITH A PERFORMANCE AT LEAST
 EQUIVALENT TO TWO LAYERS OF GRADE D PAPER. THE
 INDIVIDUAL LAYERS SHALL BE INSTALLED INDEPENDENTLY SUCH
 THAT EACH LAYER PROVIDES A SEPARATE CONTINUOUS PLANE
 AND ANY FLASHING (INSTALLED IN ACCORDANCE WITH SECTION
 R703.8) INTENDED TO DRAIN TO THE WATER-RESISTIVE
 BARRIER IS DIRECTED BETWEEN THE LAYERS
  
 FBC- R703.6.3 STUCCO
 WHERE CEMENT PLASTER (STUCCO) IS TO BE APPLIED TO LATH
 OVER FRAME CONSTRUCTION, MEASURES SHALL BE TAKEN TO
 PREVENT BONDING BETWEEN THE CEMENT PLASTER AND THE
 WATER-RESISTIVE BARRIER: TWO LAYERS OR ONE LAYER OF AN
 APPROVED WATER-RESISTANT BARRIER OVER AN APPROVED
 PLASTIC HOUSE WRAP, OR OTHER APPROVED METHODS IN
 ACCORDANCE WITH THE MANUFACTURER?S INSTALLATION
 INSTRUCTIONS.
  
  
 ? TABLE R702.1(1)
 THICKNESS OF PLASTER
 PLASTER BASE FINISHED THICKNESS OF PLASTER FROM FACE OF
 LATH, MASONRY, CONCRETE (INCHES)
  GYPSUM PLASTER CEMENT PLASTER
 EXPANDED METAL LATH 5/8, MINIMUMA 5/8, MINIMUMA
 WIRE LATH 5/8, MINIMUMA 3/4, MINIMUM (INTERIOR)B
  7/8, MINIMUM (EXTERIOR)B
 GYPSUM LATHG 1/2, MINIMUM 3/4, MINIMUM (INTERIOR)B
 MASONRY WALLSC 1/2, MINIMUM 1/2, MINIMUM
 MONOLITHIC CONCRETE WALLSC, D 5/8, MAXIMUM 7/8, MAXIMUM
 MONOLITHIC CONCRETE CEILINGSC, D 3/8, MAXIMUME 1/2,
 MAXIMUM
 GYPSUM VENEER BASEF, G 1/16, MINIMUM 3/4, MINIMUM
 (INTERIOR)B
 GYPSUM SHEATHINGG ? 3/4, MINIMUM (INTERIOR)B
  7/8, MINIMUM (EXTERIOR)B
 FOR SI: 1 INCH = 25.4 MM.
 A. WHEN MEASURED FROM BACK PLANE OF EXPANDED METAL
 LATH, EXCLUSIVE OF RIBS, OR SELF-FURRING LATH, PLASTER
 THICKNESS SHALL BE 3/4 INCH MINIMUM.
 B. WHEN MEASURED FROM FACE OF SUPPORT OR BACKING.
 C. BECAUSE MASONRY AND CONCRETE SURFACES MAY VARY IN
 PLANE, THICKNESS OF PLASTER NEED NOT BE UNIFORM.
 D. WHEN APPLIED OVER A LIQUID BONDING AGENT, FINISH
 COAT MAY BE APPLIED DIRECTLY TO CONCRETE SURFACE.
 E. APPROVED ACOUSTICAL PLASTER MAY BE APPLIED DIRECTLY
 TO CONCRETE OR OVER BASE COAT PLASTER, BEYOND THE
 MAXIMUM PLASTER THICKNESS SHOWN.
 F. ATTACHMENT SHALL BE IN ACCORDANCE WITH TABLE
 R702.3.5.
 G. WHERE GYPSUM BOARD IS USED AS A BASE FOR CEMENT
 PLASTER, A WATER-RESISTIVE BARRIER COMPLYING WITH
 SECTION R703.2 SHALL BE PROVIDED.
  
 VALUATION ? BASED ON THE MARSHALL-SWIFT VALUATION
 SERVICE YOUR STATED VALUE APPEARS LOW.
 THE PERMIT VALUATION AND PERMIT FEE MUST BE
 COMMENSURATE WITH THE VALUATION AND FEE THAT A LICENSED
 CONTRACTOR WOULD PROVIDE.
 YOU MAY PROVIDE A COPY OF THE CONTRACT SIGNED BY THE
 OWNER OR A LIST OF LABOR, MATERIALS AND EQUIPMENT
 RENTAL TO VERIFY VALUE.
  
 CITY OF WPB CHPT. 1 - VALUE
 109.3 BUILDING PERMIT VALUATIONS. IF, IN THE OPINION OF
 THE BUILDING OFFICIAL, THE CLAIMED VALUATION OF
 BUILDING, ALTERATION, STRUCTURE, ELECTRICAL, GAS,
 MECHANICAL OR PLUMBING SYSTEMS APPEARS TO BE
 UNDERESTIMATED ON THE APPLICATION, THE PERMIT SHALL BE
 DENIED, UNLESS THE APPLICANT CAN SHOW DETAILED,
 QUANTITY ESTIMATES, AND/OR BONA FIDE SIGNED CONTRACTS
 (EXCLUDING LAND VALUE) TO MEET THE APPROVAL OF THE
 BUILDING OFFICIAL. FOR PERMITTING PURPOSES, VALUATION
 OF BUILDINGS AND SYSTEMS SHALL BE TOTAL REPLACEMENT
 VALUE TO INCLUDE STRUCTURAL, ELECTRIC, PLUMBING,
 MECHANICAL, INTERIOR FINISH, RELATIVE SITE WORK,
 ARCHITECTURAL AND DESIGN FEES, MARKETING COSTS,
 OVERHEAD AND PROFIT; EXCLUDING ONLY LAND VALUE.
 VALUATION REFERENCES MAY INCLUDE THE LATEST PUBLISHED
 DATA OF NATIONAL CONSTRUCTION
 COST ANALYSIS SERVICES (MARSHALL-SWIFT, MEANS, ETC.),
 AS PUBLISHED BY INTERNATIONAL CODE CONGRESS.
 FINAL BUILDING PERMIT VALUATION SHALL BE SET BY THE
 BUILDING OFFICIAL.
  
  
  
  
  