2017-08-23 12:42:071ST REVIEW: FBC 2014 5TH EDITION
  
 PLUMBING COMMENTS:
  
 NOTE THIS BUILDING WAS BUILT / PERMITTED IN 2004. THIS
 BUILDING IS SUBJECT TO FAIR HOUSING REQUIREMENTS.
 2014 FLORIDA ACCESSIBILITY CODE/ FAIR HOUSING
 ACCESSIBILITY GUIDELINES. SECTION 3. FAIR HOUSING ACT
 DESIGN AND CONSTRUCTION REQUIREMENTS. FOR PURPOSES OF
 THIS SECTION, A COVERED MULTIFAMILY DWELLING SHALL BE
 DEEMED TO BE DESIGNED AND CONSTRUCTED FOR FIRST
 OCCUPANCY ON OR BEFORE MARCH 13, 1991, IF THEY ARE
 OCCUPIED BY THAT DATE OR IF THE LAST BUILDING PERMIT OR
 RENEWAL THEREOF FOR THE COVERED MULTIFAMILY DWELLINGS
 IS ISSUED BY A STATE, COUNTY OR LOCAL GOVERNMENT ON OR
 BEFORE JANUARY 13, 1990.
  
 1. PLEASE INDICATE ON THE PLAN WHAT DESIGN SPEC IS
 BEING USED FOR THE FHA REQUIREMENTS A OR B
 2. PLEASE SHOW THE REQUIRED CLEAR FLOOR SPACE FOR THE
 NEW SHOWER PER FHA GUIDELINES
 3. PLEASE SHOW REQUIRED BACKING FOR GRAB BARS PER FHA
 GUIDELINES
  
 PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS.
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT
 CORRECTED PAGES INTO TO SUBMITTAL AND REMOVE OR VOID
 THE PREVIOUSLY REVIEWED SHEETS.
  