| 2017-08-30 11:30:47 | BUILDING PLAN REVIEW |
| | 2014 FLORIDA BUILDING CODE W/2010 WEST PALM BEACH |
| | AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1 |
| | ADMINISTRATION |
| | |
| | CHRISTOPHER S. THROOP, C.B.O. |
| | PLANS EXAMINER, PX3169 |
| | CONSTRUCTION SERVICES DIVISION |
| | TEL: 561-805-6726 |
| | FAX: 561-805-6676 |
| | |
| | 1ST REVIEW |
| | RESULTS: DENIED |
| | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT |
| | |
| | BLDG. # 1 354 MARLBOROUGH PL. |
| | |
| | 1. OWNER/AGENT TO SIGN ENERGY SUBMITTAL. |
| | 2. PRODUCT APPROVALS/NOA'S SUBMITTED DO NOT MATCH |
| | PRODUCT APPROVAL SCHEDULE ON PLANS (WINDOWS, DOORS & |
| | ROOFING). PLEASE CLARIFY. |
| | 3. DESIGNER TO REVIEW AND APPROVE IN WRITING ALL |
| | PRODUCT APPROVALS. INDICATE MODEL OF DOOR TO BE |
| | INSTALLED. |
| | 4. ROOF DESIGN PRESSURE TABLE ON PLAN PAGE A.4 STATES |
| | MEAN ROOF HEIGHT IS 15 FT. BOTH STRUCTURES ARE TWO |
| | STORY. PLEASE CLARIFY. |
| | 5. STAIR DETAIL ON PLAN PAGE A.5 INDICATES MAX. RISER |
| | HEIGHT TO BE 8" MAX. RISER HEIGHT SHALL NOT EXCEED |
| | 73/4" PER FBC R 311.7.5.1. |
| | |
| | FBCE-R101.5.1.1 BUILDING THERMAL ENVELOPE ALTERNATIVE. |
| | AN ACCURATELY COMPLETED RESIDENTIAL BUILDING FORM R402 |
| | SHALL BE SUBMITTED TO THE BUILDING OFFICIAL TO |
| | DEMONSTRATE CODE COMPLIANCE BY THIS METHOD. |
| | |
| | _ OR _ |
| | |
| | FBCE-101.5.1.1.2 SIMULATED PERFORMANCE ALTERNATIVE. |
| | AN ACCURATELY COMPLETED RESIDENTIAL BUILDING FORM R405 |
| | (GENERATED BY COMMISSION APPROVED SOFTWARE) SHALL BE |
| | SUBMITTED TO THE BUILDING OFFICIAL TO DEMONSTRATE CODE |
| | COMPLIANCE BY SECTION 405. |
| | |
| | FBC 107.3.4 - PROVIDE PRODUCT APPROVALS FOR THOSE |
| | PRODUCTS WHICH ARE REGULATED BY FAC RULE 9N-3 REVIEWED |
| | AND APPROVED IN WRITING BY THE DESIGNER OF RECORD. |
| | SPECIFICALLY, PROVIDE ROOFING, WINDOW, AND DOOR |
| | SUBMITTALS. |
| | |
| | R311.7.5.1 RISERS. |
| | THE MAXIMUM RISER HEIGHT SHALL BE 73/4 INCHES (196 MM). |
| | THE RISER SHALL BE MEASURED VERTICALLY BETWEEN LEADING |
| | EDGES OF THE ADJACENT TREADS. THE GREATEST RISER HEIGHT |
| | WITHIN ANY FLIGHT OF STAIRS SHALL NOT EXCEED THE |
| | SMALLEST BY MORE THAN 3/8 INCH (9.5 MM). RISERS SHALL |
| | BE VERTICAL OR SLOPED FROM THE UNDERSIDE OF THE NOSING |
| | OF THE TREAD ABOVE AT AN ANGLE NOT MORE THAN 30 DEGREES |
| | (0.51 RAD) FROM THE VERTICAL. OPEN RISERS ARE PERMITTED |
| | PROVIDED THAT THE OPENING BETWEEN TREADS DOES NOT |
| | PERMIT THE PASSAGE OF A 4-INCH-DIAMETER (102 MM) |
| | SPHERE. |
| | |
| | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE |
| | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY |
| | RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT |
| | CORRECTED PAGES INTO SUBMITTAL AND LEAVE THE PREVIOUSLY |
| | REVIEWED SHEETS DETACHED AND MARK VOID. |
| | |
| | |