| 2017-11-13 18:44:17 | |
| | NOTE: |
| | 01/05/18 OWNER P/U PLUMBING/MECHANICAL DRAWING TO GET |
| | NAME AND SIGNATURE OF DESIGNER OF RECORD. JG. |
| | |
| | |
| | RESIDENTIAL (R3) CHANGE OF USE/ALTERATION, SECOND |
| | BUILDING REVIEW CHECKLIST. |
| | CODE: FBC 5TH EDITION (2014). |
| | |
| | 1- AFTER PLANS ARE REVISED, BRING THEM TO PALM BEACH |
| | COUNTY (2300 N. JOG RD.) FOR IMPACT FEE ASSESSMENT. |
| | BRING BACK COUNTY STAMPED PLANS AND COPY OF IMPACT FEES |
| | PAID RECEIPT IF FEES ARE DUE. COUNTY IMPACT FEE |
| | ORDINANCE OF THE UNIFIED LAND DEVELOPMENT CODE. |
| | RESPONSE: THIS MAY BE DONE LATER AFTER THE PLANS ARE |
| | APPROVED BY ALL TRADES AND PERMIT IS READY TO BE |
| | ISSUED. |
| | |
| | 2- PROVIDE ENERGY CALCULATIONS (2 COPIES) AS REQUIRED |
| | BY SEC. R101.4.3 FBC-ENERGY CONSERVATION, 5TH EDITION |
| | (2014). |
| | RESPONSE: |
| | REPEAT COMMENT. NOT ADDRESSED AT ALL. |
| | |
| | 3- THE PROPOSED BEDROOM NEEDS THE EMERGENCY ESCAPE AND |
| | RESCUE OPENING AS REQUIRED BY SEC. R310.1 |
| | FBC-RESIDENTIAL, 5TH EDITION (2014). |
| | RESPONSE: |
| | SINGLE HUNG WINDOW SIZE SPECIFIED ON PLANS DON'T COMPLY |
| | WITH THE MINIMUM CLEAR HEIGHT REQUIRED BY SEC. R310.1.2 |
| | FBC-RESIDENTIAL. FLOOR PLAN ON SHEET A.1 SPECIFIES 53 X |
| | 51 SINGLE HUNG WINDOW. THIS WINDOW SIZE DOESN'T PROVIDE |
| | THE 24" CLEAR HEIGHT OPENING. ALSO, FLOOR PLAN ON SHEET |
| | A.1 SPECIFIES SH-25, WHILE SOUTH ELEVATION ON SHEET A.2 |
| | SPECIFIES SH-34. INFORMATION DOESN'T MATCH. CLEARLY |
| | SPECIFY ONE SIZE OF WINDOW THAT COMPLIES WITH ALL THE |
| | EGRESS REQUIREMENTS. |
| | |
| | NOTE: ENGINEER OF RECORD MAY BE CHARGED 4 TIMES THE |
| | PLAN REVIEW AS REQUIRED BY FLORIDA STATUTE 553.80(2)(B) |
| | FOR MULTIPLE PLAN REVIEW REJECTIONS. |
| | |
| | 4- PLANS SPECIFY EXISTING 3'-0 X 6'-8" ENTRY DOOR AND |
| | EXISTING SINGLE HUNG WINDOW. THERE ARE NO CITY RECORDS |
| | FOR THE INSTALLATION OF THE ENTRY DOOR. ALSO, PHOTOS ON |
| | THE INTERNET WHEN THE HOUSE WAS FOR SALE SHOW A GARAGE |
| | WITH NO DOORS, EXCEPT FOR THE OPENING FOR A GARAGE |
| | DOOR. AND THE WINDOW SEEMS TO BE FAIRLY NEW. SEE |
| | ATTACHED PHOTO. PERMIT IS REQUIRED FOR THE INSTALLATION |
| | OF NEW DOOR AND REPLACEMENT OF WINDOWS. PRODUCT |
| | APPROVALS WILL BE REQUIRED. SEE ITEM # 8 BELOW. REVISE |
| | INFORMATION ON PLANS AND PROVIDE COMPLETE INFORMATION |
| | FOR THE FRAMING OF THE ENTRY DOOR. SEC. R301.1 |
| | FBC-RESIDENTIAL. |
| | RESPONSE: |
| | PLANS STILL CALL FOR EXISTING DOOR. PLANS WERE REVISED |
| | SHOWING THE VERTICAL REINFORCEMENT FOR THE WINDOW, BUT |
| | DON'T SHOW THE VERTICAL REINFORCEMENT FOR THE ENTRY |
| | DOOR. REVISE ALL PLANS AS REQUIRED. |
| | |
| | 5- PROVIDE PRODUCT APPROVAL (2 COPIES) AS REQUIRED BY |
| | FAC 61G20-3.001 FOR: |
| | A) ENTRY DOOR AS SHOWN ON PLANS. |
| | RESPONSE: |
| | REPEAT COMMENT. NOT ADDRESSED. |
| | |
| | B) SINGLE HUNG WINDOW AS SHOWN PLANS. |
| | RESPONSE: |
| | REPEAT COMMENT. NOT ADDRESSED. |
| | |
| | C) HURRICANE SHUTTERS IF WINDOW AND DOORS WITH GLAZING |
| | DON'T HAVE IMPACT GLAZING. AND, PROVIDE COMPLETE |
| | INSTALLATION SCHEDULE. SEE CITY SAMPLE. |
| | RESPONSE: |
| | REPEAT COMMENT. NOT ADDRESSED. |
| | |
| | 6- ENGINEER OF RECORD TO REVIEW AND APPROVE IN WRITING |
| | (NOT SIGNING AND SEALING) ABOVE PRODUCT APPROVALS AS |
| | REQUIRED BY SEC. 107.3.4.1 CITY AMENDMENTS. |
| | RESPONSE: |
| | REPEAT COMMENT. NOT ADDRESSED. |
| | |
| | 7- ENGINEER OF RECORD TO CLARIFY WHY THE ROOF LIVE LOAD |
| | SPECIFIED ON THE DESIGN PARAMETERS AND STRUCTURAL NOTE |
| | #2 ON SHEET A.1 IS ONLY 10PSF?. WHERE IS THIS DESIGN |
| | CRITERIA TAKEN FROM? PROVIDE WRITTEN RESPONSE. SEC. |
| | R301.1 FBC-RESIDENTIAL. |
| | RESPONSE: |
| | LOADS SPECIFIED ON "DESIGN PARAMETERS" DON'T MATCH |
| | LOADS SPECIFIED ON "STRUCTURAL NOTES" ON THE SAME |
| | SHEET. ENGINEER TO REVISE INFORMATION AS REQUIRED TO |
| | MATCH. |
| | |
| | 8- VALUATION DECLARED IN THE PERMIT APPLICATION IS TOO |
| | LOW. VALUATION TO INCLUDE ALL LABOR, MATERIALS, |
| | CONTRACTOR'S OVERHEAD AND PROFIT AND ALL DESIGN |
| | PROFESSIONAL FEES AS REQUIRED BY SEC. 109.3 CITY |
| | AMENDMENTS. |
| | |
| | NOTE: WHEN SURVEY IS SUBMITTED ADDITIONAL COMMENTS MAY |
| | APPLY DEPENDING ON THE DISTANCE FROM THE STRUCTURE TO |
| | THE PROPERTY LINES. |
| | |
| | IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT |
| | JULIO GOMEZ |
| | COMMERCIAL COMBINATION PLANS EXAMINER |
| | DEVELOPMENT SERVICES DEPARTMENT |
| | BUILDING DIVISION |
| | (561)805-6712 |
| | [email protected] |