2017-08-02 16:07:16****CORRECTIONS****
  
 SAMANTHA HILL
 BUILDING PLANS EXAMINER
 [email protected]
 561-805-6724
  
 FBC = FLORIDA BUILDING CODE, 5TH EDITION (2014)
 FBC B = FBC BUILDING
 FBC EB = FBC EXISTING BUILDING
 FBC A = FBC ACCESSIBILITY
 FBC EC = FBC ENERGY CONSERVATION
  
 1. FS489, CLARIFY SCOPE OF WORK FOR WADMAN FABRICATORS.
 I WAS UNABLE TO FIND A LICENSE NUMBER FOR THIS COMPANY
 ON DBPR WEBSITE. WILL THIS WORK BE DONE ON SITE OR OFF
 SITE?
  
 2. S1.0, FBC B TABLE 1607.1(26), ALL ROOF SURFACES
 SUBJECT TO MAINTENANCE WORKERS TO BE DESIGNED TO A 300#
 LIVE LOAD, 20# SPECIFIED, CLARIFY OR REVISE.
  
 3. THIS APPEARS TO BE LOCATED IN EXPOSURE C, SEE FBC
 1609.4, SEE ALSO ASCE7-10 AND COMMENTARY. THE LARGE
 OPEN SPACE (PARKING LOT) CREATES A PATCH CONDITION IN
 THAT DIRECTION, THE AREA TO THE NORTH AND AREA TO THE
 NORTHWEST ARE OPEN; REVISE PLAN (AND DESIGN, IF
 NECESSARY) TO EXPOSURE C OR EMAIL RATIONALE FOR
 EXPOSURE B VIA EMAIL PRIOR TO RESUBMITTAL.
  
 4. DETAIL 1-S1.0 SPECS SELF DRILLING SCREWS PER
 MANUFACTURER REQUIREMENTS. DETAIL 2-M2 ALSO REFERS TO
 MANUFACTURER INSTRUCTIONS. FBC B 1609, REVISE DETAILS
 TO SPECIFY FASTENING INCLUDING DIAMETER, LENGTH,
 FASTENING PATTERN. IF THIS WILL BE DELEGATED
 ENGINEERING PER FLORIDA ADMINISTRATIVE CODE 61G15-30,
 PROVIDE THE DELEGATED ENGINEERING (UNIT FASTENING TO
 CURB, ANY OTHER ) AT THIS TIME. STRUCTURAL ENGINEER OF
 RECORD (SEOR) TO REVIEW DELEGATED ENGINEERING PRIOR TO
 SUBMITTAL.
  
 OTHER STRUCTURAL SPECS ARE ALSO TOO GENERAL TO SHOW
 COMPLIANCE WITH FBC B 1609, RESISTANCE TO WIND LOADS.
 FOR INSTANCE, 1-M2 REFERS TO "HOLD DOWN BRACKETS".
  
 5. SOME PAGES ARE NOT SIGNED AND SEALED IN ACCORDANCE
 WITH FLORIDA STATUTE 471. PRIOR TO RESUBMITTAL, VERIFY
 THAT ALL PAGES INCLUDE AN ORIGINAL "WET" SIGNATURE. FOR
 INSTANCE, SEE STRUCTURAL PAGES (NOT ORIGINAL SIGNATURE,
 WAS DIGITALLY SIGNED AND SEALED). CHECK ALL PAGES PRIOR
 TO RESUBMITTAL.
  
 6. TITLE BLOCK FOR DONALD C. CARROLL, PE IS NOT CLEAR.
 SEE FS471, FAC61G15-23.002. REVISE S1.0 TO INCLUDE OR
 CLARIFY.
  
 7. SEE FLORIDA STATUTE 471.0195; THE DBPR WEBSITE
 (MYFLORIDALICENSE.COM) DOES NOT REFLECT THAT THE
 FOLLOWING HAVE TAKEN THE ADVANCED FLORIDA BUILDING CODE
 COURSE. PLEASE SEND EVIDENCE THAT THE COURSE WAS
 COMPLETED TO FBPE AND REQUEST THAT THEY UPDATE THE
 WEBSITE. THIS COURSE IS DUE WITHIN ONE YEAR AFTER THE
 ADOPTION OF THE FBC (WAS DUE JUNE 30, 2016).
  
 JASON M. SCATES, PE
 RICKY N TERRELL, PE
 RANDALL C. HAASE, PE
  
 THIS WILL NOT DELAY PERMIT ISSUANCE.
  
 8. FBC 109, VALUE TO INCLUDE LABOR, MATERIALS,
 OVERHEAD, PROFIT, INCLUDING ITEMS PROVIDED BY OTHERS.
 PLAN NOTES THAT SOME ITEMS WILL BE PROVIDED BY WALMART;
 VERIFY THAT THE VALUE OF THOSE ITEMS ARE INCLUDED IN
 PERMIT VALUE.
  
 9. SHEETS S1.1 THROUGH S4.0 ARE BLANK; PLEASE REMOVE,
 FBC 107.
  
  