| Date |
Text |
| 2017-08-01 11:15:35 | 08/01/17 YANIL ESPINAL E-MAILED BACK. THEY ARE GETTING |
| | THE PRODUCT APPROVALS TO RE-SUBMIT. PLANS IN BACK LARGE |
| | PLANS SHELF UNDER "J". JG. |
| | |
| | |
| | |
| | |
| | |
| | BUILDING REVIEW APPROVED WITH PROVISO: |
| | 1- FLAT ROOF NOA 14-0529.02 SUBMITTED: PROVIDE SIGNED |
| | AND SEALED RAS 117 CALCULATIONS AS REQ'D GENERAL |
| | LIMITATION #7. |
| | |
| | 2- ARCHITECT TO REVISE THE DESIGN PRESSURES FOR THE |
| | OVERHEAD GARAGE DOOR TO CORRESPOND TO EXPOSURE "D". SEE |
| | SHEET A3.1 |
| | |
| | 3- PROVIDE PRODUCT APPROVAL (2 COPIES) FOR: |
| | A) BALCONY DECK UNDERLAYMENT. NOTE: NEED PRODUCT |
| | APPROVAL THAT IS DESIGNED TO BE USED WITH THE SPECIFIC |
| | DECK FINISH MATERIAL TO BE INSTALLED IN THIS HOUSE. IN |
| | ADDITION CLEARLY IDENTIFY SPECIFIC ASSEMBLY TO BE |
| | INSTALLED AND PROVIDE SIGNED AND SEALED RAS 117 |
| | CALCULATIONS IF REQUIRED. |
| | |
| | B) ROOF CLAY TILE. NOA 12-0210.01 SUBMITTED EXPIRED ON |
| | 02/01/16. |
| | |
| | C) ROOF TILE ADHESIVE. SEE ROOF TILE PRODUCT APPROVAL |
| | FOR LISTED ADHESIVES. |
| | |
| | D) OVERHEAD GARAGE DOOR THAT MEETS THE DESIGN PRESSURES |
| | CALCULATED BY THE ARCHITECT OF RECORD. COORDINATE WITH |
| | ITEM #2 ABOVE. |
| | |
| | E) SINGLE HUNG WINDOWS. NEED LARGE MISSILE IMPACT |
| | RESISTANT PRODUCT APPROVAL. NOA 15-0512.08 SUBMITTED IS |
| | FOR SMALL MISSILE IMPACT RESISTANT. |
| | |
| | F) WINDOW MULLIONS AS SHOWN ON PLANS. AND, SPECIFY |
| | MULLION SIZE. |
| | |
| | G) FIXED WINDOWS AS SPECIFIED ON PLANS. |
| | |
| | H) GUEST HOUSE EXTERIOR SWING DOOR AS SHOWN ON PLANS. |
| | |
| | 4- ARCHITECT OF RECORD TO REVIEW AND APPROVE ABOVE |
| | PRODUCT APPROVALS. |