| Date |
Text |
| 2017-08-22 08:40:22 | 1ST REVIEW: FBC 2014 5TH EDITION |
| | |
| | PLUMBING COMMENTS: |
| | |
| | 1. THE WALLS AROUND THE MOP SINK SHALL COMPLY WITH FBC |
| | B 1210.2.2 |
| | |
| | 2. PLEASE SHOW COMPLIANCE WITH FBC ACC 604.7 |
| | DISPENSERS. |
| | TOILET PAPER DISPENSERS SHALL COMPLY WITH 309.4 AND |
| | SHALL BE 7 INCHES (180 MM) MINIMUM AND 9 INCHES (230 |
| | MM) MAXIMUM IN FRONT OF THE WATER CLOSET MEASURED TO |
| | THE CENTERLINE OF THE DISPENSER. |
| | |
| | 3. THE SIDE GRAB BAR FOR THE TOILET SHALL COMPLY WITH |
| | FBC ACC 604.5.1 SIDE WALL. |
| | THE SIDE WALL GRAB BAR SHALL BE 42 INCHES (1065 MM) |
| | LONG MINIMUM, LOCATED 12 INCHES (305 MM) MAXIMUM FROM |
| | THE REAR WALL AND EXTENDING 54 INCHES (1370 MM) MINIMUM |
| | FROM THE REAR WALL. |
| | |
| | 4. PLEASE SHOW DIMENSIONS FOR SHOWER SEAT PER FBC ACC |
| | 610.3 SHOWER COMPARTMENT SEATS.IN TRANSFER-TYPE |
| | SHOWERS, THE SEAT SHALL EXTEND FROM THE BACK WALL TO A |
| | POINT WITHIN 3 INCHES (75 MM) OF THE COMPARTMENT ENTRY. |
| | THE TOP OF THE SEAT SHALL BE 17 INCHES (430 MM) MINIMUM |
| | AND 19 INCHES (485 MM) MAXIMUM ABOVE THE BATHROOM |
| | FINISH FLOOR. SEATS SHALL COMPLY WITH 610.3.1 OR |
| | 610.3.2. |
| | 610.3.2 L-SHAPED SEATS. |
| | THE REAR EDGE OF AN L-SHAPED SEAT SHALL BE 21/2 INCHES |
| | (64 MM) MAXIMUM AND THE FRONT EDGE 15 INCHES (380 MM) |
| | MINIMUM AND 16 INCHES (405 MM) MAXIMUM FROM THE SEAT |
| | WALL. THE REAR EDGE OF THE L PORTION OF THE SEAT SHALL |
| | BE 11/2 INCHES (38 MM) MAXIMUM FROM THE WALL AND THE |
| | FRONT EDGE SHALL BE 14 INCHES (355 MM) MINIMUM AND 15 |
| | INCHES (380 MM) MAXIMUM FROM THE WALL. THE END OF THE L |
| | SHALL BE 22 INCHES (560 MM) MINIMUM AND 23 INCHES |
| | MAXIMUM (585 MM) FROM THE MAIN SEAT WALL. |
| | |
| | 5. PLEASE SHOW COMPLIANCE WITH FBC ACC 608.5.1 TRANSFER |
| | TYPE SHOWER COMPARTMENTS. |
| | IN TRANSFER TYPE SHOWER COMPARTMENTS, THE CONTROLS, |
| | FAUCETS, AND SHOWER SPRAY UNIT SHALL BE INSTALLED ON |
| | THE SIDE WALL OPPOSITE THE SEAT 38 INCHES (965 MM) |
| | MINIMUM AND 48 INCHES (1220 MM) MAXIMUM ABOVE THE |
| | SHOWER FLOOR AND SHALL BE LOCATED ON THE CONTROL WALL |
| | 15 INCHES (380 MM) MAXIMUM FROM THE CENTERLINE OF THE |
| | SEAT TOWARD THE SHOWER OPENING. |
| | |
| | 6. IN THE SHOWER ONLY ONE GRAB BAR IS SHOWN ON BACK |
| | WALL PLEASE SHOW COMPLIANCE WITH FBC ACC 608.3.1 |
| | TRANSFER TYPE SHOWER COMPARTMENTS. |
| | IN TRANSFER TYPE COMPARTMENTS, GRAB BARS SHALL BE |
| | PROVIDED ACROSS THE CONTROL WALL AND BACK WALL TO A |
| | POINT 18 INCHES (455 MM) FROM THE CONTROL WALL. |
| | |
| | 7. A BACKFLOW IS REQUIRED ON THE ICE MACHINE AND THE |
| | COFFEE MACHINE. PER FBC PL 608.3, 608.16.10 |
| | |
| | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED |
| | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. |
| | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE |
| | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY |
| | RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT |
| | CORRECTED PAGES INTO TO SUBMITTAL AND REMOVE OR VOID |
| | THE PREVIOUSLY REVIEWED SHEETS. |
| | |
| | GEORGE JOHNSON |
| | PLUMBING PLANS EXAMINER |
| | CITY OF WEST PALM BEACH |
| | 561-805-6711 |
| | [email protected] |
| | |