Plan Review Notes
Plan Review Notes For Permit 17070628
Permit Number 17070628
Review Stop B
Sequence Number 1
Notes
Date Text
2017-08-03 18:46:55PLAN
 REVIEW COMMENTS
  
 1ST REVIEW: FBC FIFTH EDITION (2014)
 ROBERT MCDOUGAL, CBO
 COMMERCIAL COMBINATION PLANS EXAMINER
 (561) 805-6714
 [email protected]
  
 DENIED BY BUILDING
 PLEASE ADDRESS THE ITEMS NOTED BELOW:
  
 1) PLAN SHEETS A-1, A-2 AND S-1 HAVE THE WRONG ADDRESS
 IN THE TITLE BLOCK. PLEASE CORRECT. FAC 61G1-16.004 &
 FBC 107.2.1
  
 2) PROVIDE A STRUCTURAL FRAMING DETAIL FOR THE ARCH
 OPENINGS BETWEEN THE COLUMNS. FBC-R301.2.1 & FBC
 107.2.1.3
  
 3) PLAN SHEET A-1 HAS A NOTE TO RELOCATE THE EXISTING
 BBQ AND THE SCOPE OF WORK FROM THE CONTRACTOR STATES
 THAT THE BBQ AND EXHAUST HOOD ARE TO BE DISPOSED OF.
 PLEASE CLARIFY. FBC 107.2.1
  
 4) SUBMIT MANUFACTURER'S SPECIFICATIONS, LISTINGS AND
 INSTALLATION INSTRUCTIONS FOR THE NEW SIDE BURNER, NEW
 BBQ AND NEW EXHAUST HOOD. FBC 107.2.1 & FBC 107.2.1.3
  
 5) FBC 107.3.4 - PROVIDE TWO SETS OF PRODUCT APPROVALS
 FOR THOSE PRODUCTS WHICH ARE REGULATED BY FAC
 61G20-3.001 PER FLORIDA STATUTE 553.842 (5) THAT HAVE
 BEEN REVIEWED AND APPROVED IN WRITING BY THE DESIGNER
 OF RECORD. PROVIDE TWO COMPLETE PRODUCT APPROVALS WITH
 FL OR NOA NUMBERS INCLUDING INSTALLATION INSTRUCTIONS
 AND MAXIMUM DESIGN PRESSURES FOR EACH OF THE DIFFERENT
 ROOFING MATERIALS AND ROOF TILE ADHESIVES (IF USED).
  
 6) SPECIFY THE METHOD OF ATTACHMENT THAT WILL BE USED
 TO INSTALL THE CEMENT ROOF TILES. FBC-R 905.3 & FBC-R
 301.1
  
  