Plan Review Notes
Plan Review Notes For Permit 17070531
Permit Number 17070531
Review Stop B
Sequence Number 2
Notes
Date Text
2017-09-13 11:57:321ST REVIEW: FBC 2014 5TH ED
 CITY CODE SECTION 78-490
  
 NOT APPROVED, SEE BELOW:
  
 1) ALTHOUGH YOU PROVIDED A PARKLET PERMIT APPLICATION,
 PLEASE ADDITIONALLY PROVIDE A BUILDING PERMIT
 APPLICATION FORM WITH CONTRACTOR AND OWNER INFORMATION
 AND SIGNATURES. LIST THE CITY OF WEST PALM BEACH IN BOX
 9 ON THE REAR OF THE APPLICATION.
  
 2) PROVIDE TWO SETS OF PLANS, ONLY ONE WAS FOUND.
  
 3) CITY CODE 78-497 (B)()C. - WIND RESISTANCE - SPECIFY
 THE WIND RESISTANCE STANDARD UTILIZED IN THE DESIGN OF
 THE PARKLET. PROVIDE DETAILS FOR FASTENING SUCH AS NAIL
 TYPE & SPACING, CONNECTORS AND CONNECTION TO EARTH. IS
 THERE INTENT TO DESIGN FOR WIND RESISTANCE PURSUANT TO
 FBC CHAPTER 16 FOR THE LOCATION AS RISK CATEGORY II OR
 IS THE DESIGN TO BE OF A LESSER WIND RESISTANCE WITH
 INTEND TO REMOVE IN THE EVENT OF FORCASTED HIGH WINDS.
 IF THE LATER, PROVIDE DETAILS FOR THE MAXIMUM WIND
 DESIGN. FOR EXAMPLE, IF THE INTENT IS TO REMOVE PRIOR
 TO FORECASTED 75 MPH WINDS, PROVIDE A DESIGN CAPABLE OF
 WITHSTANDING 90 MPH WINDS AND PROVIDE THE REMOVAL PLAN.
  
 4) CITY CODE 78-497 (B)(1)F. - ACCESSIBILITY - PLEASE
 INDICATE THE INTENT TO COMPLY WITH FBC ACCESSIBILITY
 CHAPTER 3 AS TO APPROACH, GROUND SURFACES, OPENINGS IN
 FLOOR SURFACES, CHANGES IN LEVEL, AND TURNING SPACE,
 MANEUVERING, AND CLEARANCES AND TABLE TOP HEIGHTS PER
 CHAPTER 3. ADDITIONALLY, PROVIDE A SEATING PLAN TO SHOW
 COMPLIANCE WITH FBC ACCESSIBILITY TABLE 221.2.1.1
  
 STEVEN KENNEDY, CBO
 ASSISTANT BUILDING OFFICIAL
 (561) 805-6710
 [email protected]
  