| 2017-12-01 08:34:00 | 11/30/17 CHRISTINA FROM W DEVELOPMENT GROUP LEFT VOICE |
| | MAIL MESSAGE INDICATING THAT THEY WANT TO GO WITH THE |
| | PROVISO. JG. |
| | |
| | |
| | BUILDING REVIEW APPROVED WITH PROVISO: |
| | 1- PROVIDE COMPLETE DETAILS AND SPECS WITH ALL FRAMING |
| | MEMBERS AND CONNECTORS FOR: |
| | A) ALL METAL LOUVERS. B) BAHAMA SHUTTERS. C) COLONIAL |
| | SHUTTERS. D) ALUMINUM TRELLIS. |
| | 2- PROVIDE ROOF TILE FASTENING SPECS ON PLANS. |
| | 3- PROVIDE PRODUCT APPROVAL (2 COPIES) FOR: A)FLAT |
| | ROOF. NOTE: IDENTIFY ASSEMBLY AND PROVIDE SIGNED & |
| | SEALED RAS 117 CALCULATIONS IF REQ'D B)BALCONIES |
| | UNDERLAYMENT DESIGNED TO RECEIVE TILE/STONE. NOTE: |
| | IDENTIFY ASSEMBLY AND PROVIDE SIGNED & SEALED RAS 117 |
| | CALCULATIONS IF REQ'D. C)FRENCH DOORS NOA 15-0602.09: |
| | PROVIDE UNCUT LEGIBLE DRWGS. D)FIXED WINDOWS NOA |
| | 140923.08: IDENTIFY GLASS TYPE AND ANCHOR TYPE. SEE |
| | DESIGN LOAD TABLE ON DRAWING SHEET 3 OF 7. NOTE: SOME |
| | WINDOWS DON'T MEET THE DESIGN PRESSURES. E) SIDELITE |
| | WINDOW "P" SIZE FOR DINING ROOM FRENCH DOORS. OR |
| | PROVIDE PRODUCT APPROVAL FOR FRENCH DOORS WITH |
| | SIDELITES. F)WINDOW AND DOOR MULLIONS. AND SPECIFY |
| | MULLION SIZES USED. G) ALL SIMPSON STRUCTURAL |
| | CONNECTORS SPECIFIED ON PLANS. PROVIDE CURRENT |
| | EVALUATION REPORTS OR CURRENT FLORIDA PRODUCT APPROVAL |
| | REPORTS. REPORTS SUBMITTED ARE EXPIRED. |
| | 4- DESIGNER OF RECORD TO APPROVE IN WRITING ABOVE |
| | PRODUCT APPROVALS. |
| | 5- PROVIDE MANUFACTURER'S SPECS FOR THE CASEMENT EGRESS |
| | WINDOWS SHOWING THAT THE SPECIFIED SIZES MEET ALL THE |
| | EGRESS REQUIREMENTS, INCLUDING THE WINDOWS ON THE |
| | SECOND FLOOR. ******PROVIDE INFORMATION PRIOR TO |
| | PURCHASING WINDOWS TO AVOID CONFLICTS. |