2017-10-20 15:14:06RESIDENTIAL (R3) ADDITION/ALTERATION SECOND BUILDING
 REVIEW CHECKLIST.
 CODE: FBC 5TH EDITION (2014).
  
 NOTE:
 ENGINEER OF RECORD MAY BE CHARGED 4 TIMES THE PLAN
 REVIEW FEE AS REQUIRED BY FLORIDA STATUTE 553.80(2)(B)
 FOR MULTIPLE PLANS REJECTIONS.
  
 1- AFTER PLANS ARE REVISED BRING THEM TO PALM BEACH
 COUNTY (2300 N. JOG RD.) FOR IMPACT FEES ASSESSMENT.
 BRING BACK COUNTY STAMPED PLANS AND COPY OF PAID
 RECEIPT IF FEES ARE DUE. COUNTY IMPACT FEE ORDINANCE OF
 THE UNIFIED LAND DEVELOPMENT CODE.
 RESPONSE: REPEAT COMMENT. AFTER PLANS ARE REVISED BY
 THE ENGINEER, BRING THEM TO PALM BEACH COUNTY FOR
 IMPACT FEES ASSESSMENT.
  
 2- PROPOSED EGRESS WINDOW DOESN'T COMPLY WITH THE
 EGRESS REQUIREMENTS OF SEC. R310 FBC-RESIDENTIAL. 5TH
 EDITION (2014). NEED TO COMPLY WITH THE MINIMUM WIDTH
 OPENING, MINIMUM HEIGHT OPENING AND MINIMUM TOTAL CLEAR
 OPENING. SEE SEC. R310 FBC-RESIDENTIAL, 5TH EDITION
 (2014) AND REVISE AS REQUIRED. SH-33 DOESN'T COMPLY.
 RESPONSE: REPEAT COMMENT. NOT ADDRESSED. NOTE: REVISE
 SIZE OF WINDOW AND CLEARLY SPECIFY SIZE. SEE PRODUCT
 APPROVAL FOR STANDARD SIZES.
  
 3- PROVIDE ENERGY CALCULATIONS (2 COPIES) AS REQUIRED
 BY SEC. R101.4.3 FBC-ENERGY CONSERVATION, 5TH EDITION
 (2014).
 RESPONSE: REPEAT COMMENT. NOT ADDRESSED.
  
 4- PLANS NEED TO PROVIDE INFORMATION SHOWING COMPLIANCE
 WITH THE HEATING REQUIREMENTS OF SEC. R303.9
 FBC-RESIDENTIAL. NOTE: PORTABLE HEATERS ARE NOT
 ALLOWED.
 RESPONSE: REPEAT COMMENT. NOT ADDRESSED.
  
 5- NEW BATHROOM WINDOW TO COMPLY WITH THE SAFETY
 GLAZING REQUIREMENTS OF SEC. R308.4.5 FBC-RESIDENTIAL
 IF THE WINDOW DOESN'T HAVE IMPACT GLASS.
 RESPONSE: REPEAT COMMENT. NOT ADDRESSED. WINDOWS
 PRODUCT APPROVAL WAS NOT SUBMITTED. UNABLE TO VERIFY IF
 WINDOWS ARE GOING TO BE IMPACT RESISTANT OR NOT.
  
 6- PROVIDE DETAILS AND SPECIFICATIONS SHOWING HOW THE
 NEW CONCRETE BLOCK WALL IS ATTACHED TO THE EXISTING
 WOOD BEAM. SEC. R301.1 FBC-RESIDENTIAL.
 RESPONSE: REPEAT COMMENT. NOT ADDRESSED.
  
 7- TYPICAL WALL SECTION: SPECIFY FOOTING REINFORCEMENT.
 SEC. R301.1 FBC-RESIDENTIAL.
 RESPONSE: REPEAT COMMENT. NOT ADDRESSED.
  
 8- PROVIDE PRODUCT APPROVAL (2 COPIES) AS REQUIRED BY
 FAC 61G20-3.001 FOR;
 A) SINGLE HUNG WINDOWS AS SPECIFIED ON PLANS.
 RESPONSE: REPEAT COMMENT. NOT ADDRESSED.
  
 B) WINDOW MULLION AS SPECIFIED ON PLANS. AND, SPECIFY
 MULLION SIZE TO VERIFY COMPLIANCE WITH SEC. R301.1
 FBC-RESIDENTIAL.
 RESPONSE: REPEAT COMMENT. NOT ADDRESSED.
  
 C) ARCHED FIXED WINDOW AS SPECIFIED ON PLANS.
 RESPONSE: REPEAT COMMENT. NOT ADDRESSED.
  
 D) PRECAST LINTELS AS SPECIFIED ON PLANS.
 RESPONSE: REPEAT COMMENT. NOT ADDRESSED.
  
 E) HURRICANE SHUTTERS IF THE WINDOWS PRODUCT APPROVALS
 DON'T HAVE HURRICANE IMPACT GLASS. AND, PROVIDE
 COMPLETE INSTALLATION SCHEDULE. SEE CITY SAMPLE.
 RESPONSE: REPEAT COMMENT. NOT ADDRESSED.
  
 9- ENGINEER OF RECORD TO REVIEW AND APPROVE IN WRITING
 (NOT SIGNING AND SEALING) ALL PRODUCT APPROVALS AS
 REQUIRED BY SEC. 107.3.4.1 CITY AMENDMENTS.
 RESPONSE: REPEAT COMMENT. NOT ADDRESSED.
  
 10- VALUATION DECLARED IN THE PERMIT APPLICATION IS TOO
 LOW. VALUATION TO INCLUDE ALL LABOR, MATERIALS,
 CONTRACTOR'S OVERHEAD AND PROFIT (EVEN FOR OWNER
 BUILDER) AND ALL DESIGN PROFESSIONAL FEES AS REQUIRED
 BY SEC. 1098.3 CITY AMENDMENTS. REVISE VALUATION AS
 REQUIRED.
 RESPONSE: REPEAT COMMENT. NOT ADDRESSED.
  
 *******ENGINER TO PROVIDE RESPONSE LETTER ADDRESING
 EACH COMMENT TO HELP EXPEDITE THE REVIEW PROCESS.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT
 JULIO GOMEZ
 COMMERCIAL COMBINATION PLANS EXAMINER
 DEVELOPMENT SERVICES DEPARTMENT
 BUILDING DIVISION
 (561)805-6712
 [email protected]


Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved