Plan Review Notes
Plan Review Notes For Permit 17070377
Permit Number 17070377
Review Stop ENG
Sequence Number 2
Notes
Date Text
2017-11-17 11:06:14STORMWATER POLLUTION PREVENTION MEASURES- NPDES
  
 PER SFWMD (SOUTH FLORIDA WATER MANAGEMENT) CRITERIA,
 ALL PROJECTS SHALL PROVIDE ONSITE RETENTION FOR A
 VOLUME EQUIVALENT TO THE FIRST INCH OF RUNOFF FROM THE
 DEVELOPED PROJECT, OR THE TOTAL RUNOFF OF 2.5 INCHES
 TIMES THE PERCENTAGE OF IMPERVIOUSNESS, WHICHEVER IS
 THE GREATER. IN ADDITION, COMMERCIAL/INDUSTRIAL
 DEVELOPMENTS MUST ALSO PROVIDE DRY RETENTION OR
 EXFILTRATION TRENCH SYSTEM FOR ONE-HALF (1/2) INCH OF
 RUNOFF FROM THE TOTAL PROJECT AREA.
  
 A. PRIOR TO CLEARING AND GRUBBING ACTIVITY, THE
 CONTRACTOR SHALL INSTALL EROSION AND SEDIMENTATION
 CONTROL MEASURES IN ACCORDANCE WITH FLORIDA DEPARTMENT
 OF ENVIRONMENTAL PROTECTION (FDEP) AND THE CITY OF WEST
 PALM BEACH OF ORDINANCES.
  
 B. AS CONSTRUCTION PROGRESSES, THE CONTRACTOR SHALL
 PERIODICALLY CHECK THE SEDIMENTATION CONTROLS AND
 REPAIR THEM AS NECESSARY TO KEEP THEM IN GOOD
 FUNCTIONING ORDER.
  
 C. THE CONTRACTOR SHALL PROTECT INLETS AND OTHER SITE
 APPURTENANCES FROM SEDIMENTATION USING PROTECTION AS
 DETAILED IN FDEP EROSION AND SEDIMENTATION.
  
 D. THE CONTRACTOR SHALL CONDUCT GROUND STABILIZING
 MEASURES (PAVING, GRASSING, MULCHING AND SODDING) AS
 SOON AS PRACTICABLE FOLLOWING FINAL COMPLETION OF
 CONSTRUCTION AND COMPLETED STABILIZATION OF POTENTIAL
 EROSION AREA, THE CONTRACTOR SHALL REMOVE SEDIMENTATION
 CONTROL MEASURES AND CLEAN AND REPAIR ANY AREAS
 AFFECTED BY THE CONSTRUCTION ACTIVITIES.
  
 ROADWAY/ PARKING LOTS:
  
 A. THE MINIMUM LONGITUDINAL ROADWAY SLOPE SHALL BE
 0.40%, WHILE THE MINIMUM CROSS SLOPE SHALL BE 2.00%.
 THE MAXIMUM GRADE LIMITS FOR ROADWAYS WILL VARY
 DEPENDING ON THE GEOMETRICAL CONFIGURATION AND
 ACCESSIBILITY OF VEHICLES.
  
 B. PARKING LOTS SHALL BE GRADED AS TO PROVIDE ADEQUATE
 DRAINAGE AND SAFE VEHICLE OPERATION. PARKING SERVICE
 ISLANDS SHOULD BE DESIGNED AS A TYPICAL ROADWAY SECTION
 WHERE POSSIBLE. CROSS SLOPES SHALL BE A MINIMUM OF
 1.0%. LONGITUDINAL SLOPES SHALL BE A MINIMUM OF 0.4%.
  
 C ALL COMMERCIAL AREAS SHALL BE GRADED SUCH THAT ALL
 STORM WATER RUNOFF IS DIRECTED AWAY FROM ANY STRUCTURES
 WHILE NOT ADVERSELY AFFECTING THE SURROUNDING
 PROPERTIES. ADDITIONALLY, AN ADA COMPLIANT PATH MUST BE
 PROVIDED TO ALL COMMERCIAL VERTICAL STRUCTURES.
  
 CITY OF WPB - MUNICODE
  
  
  
  


Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved