| Plan Review Notes For Permit 17070235 |
| Permit Number |
17070235 |
|
| Review Stop |
B |
| Sequence Number |
1 |
|
| Notes |
| Date |
Text |
| 2017-07-07 18:57:57 | PLAN | | | REVIEW COMMENTS | | | | | | 1ST REVIEW: FBC FIFTH EDITION (2014) | | | ROBERT MCDOUGAL, CBO | | | COMMERCIAL COMBINATION PLANS EXAMINER | | | (561) 805-6714 | | | [email protected] | | | | | | DENIED BY BUILDING | | | PLEASE ADDRESS THE ITEMS NOTED BELOW: | | | | | | 1) SPECIFY THE MEAN ROOF HEIGHT OF THIS THREE STORY | | | STRUCTURE WITH A 6/12 SLOPE ROOF. FBC 107.2.1, MEAN | | | ROOF HEIGHT. THE AVERAGE OF THE ROOF EAVE HEIGHT AND | | | THE HEIGHT TO THE HIGHEST POINT ON THE ROOF SURFACE, | | | EXCEPT THAT EAVE HEIGHT SHALL BE USED FOR ROOF ANGLE OF | | | LESS THAN OR EQUAL TO 10 DEGREES (0.18 RAD). |
|