| 2017-08-01 12:56:59 | RESIDENTIAL (R3) ALTERATION BUILDING REVIEW COMMENTS. |
| | CODE: FBC 5TH EDITION (2014). |
| | |
| | |
| | 1- AFTER PLANS ARE REVISED BRING THEM TO PALM BEACH |
| | COUNTY (2300 N. JOG RD.) FOR IMPACT FEES ASSESSMENT. |
| | BRING BACK COUNTY STAMPED PLANS AND COPY OF PAID |
| | RECEIPT IF FEES ARE DUE. COUNTY IMPACT FEE ORDINANCE OF |
| | THE UNIFIED LAND DEVELOPMENT CODE. |
| | |
| | 2- THERE ARE TWO SEPARATE STRUCTURES IN THIS PROPERTY. |
| | NEED A SEPARATE PERMIT APPLICATIONS FOR EACH STRUCTURE. |
| | ONE PERMIT APPLICATION FOR THE MAIN HOUSE AND THE OTHER |
| | ONE FOR THE GARAGE CONVERSION TO LIVABLE SPACE. SEC. |
| | 105.1 CITY AMENDMENTS. |
| | NOTE: THERE ARE NOT ADDITIONAL FEES FOR THE REAR |
| | STRUCTURE PERMIT APPLICATIONS. FEES ARE ALREADY |
| | INCLUDED IN THE OVERALL SCOPE OF WORK IN THE ORIGINAL |
| | PERMIT APPLICATION. SEPARATE PERMIT APPLICATIONS ARE TO |
| | FACILITATE AND COORDINATE ALL THE INSPECTIONS AND FOR |
| | PROPER RECORD RETENTION FILES. CONTRACTOR MAY USE SAME |
| | PLANS FOR BOTH STRUCTURES. |
| | |
| | 3- SPECIFY THE DESIGN PRESSURES FOR ALL DOORS AND |
| | WINDOWS. SEC. R301.1 FBC-RESIDENTIAL, 5TH EDITION |
| | (2014). |
| | NOTE: PRODUCT APPROVALS WILL BE REVIEWED ONCE THE |
| | CALCULATED DESIGN PRESSURES ARE PROVIDED. |
| | |
| | 4- PROPOSED CABANA ON THE EXISTING GARAGE: SHOW |
| | COMPLIANCE WITH THE HEATING REQUIREMENTS OF SEC. R303.9 |
| | FBC-RESIDENTIAL. NOTE: PORTABLE UNITS ARE NOT ALLOWED. |
| | |
| | 5- PROVIDE COMPLETE DETAILS AND SPECIFICATIONS FOR THE |
| | HANDRAILS SHOWING COMPLIANCE WITH THE LIVE LOADS OF |
| | TABLE R301.5 AND SPECIFICATIONS OF SEC. R311.7.8 AND |
| | SEC. R312.1 FBC-RESIDENTIAL. SPECIFY MATERIAL, |
| | FASTENERS, HEIGHT, PICKETS SPACING, ETC. |
| | |
| | 6- PROVIDE COMPLETE DETAILS AND SPECIFICATIONS FOR THE |
| | RISERS AND TREADS SHOWN COMPLIANCE WITH SEC. 311.7.5 |
| | FBC-RESIDENTIAL. SPECIFY RISER HEIGHT, NOSING, ETC. |
| | |
| | 7- PROVIDE PRODUCT APPROVAL (2 COPIES) AS REQUIRED BY |
| | FAC 61G20-3.001 FOR: |
| | A) STORAGE SINGLE FIBERGLASS DOOR AS SHOWN ON PLANS. |
| | FLORIDA PRODUCT APPROVAL FL17184.12 SUBMITTED IS FOR |
| | DOOR WITH SIDE-LITE ASSEMBLY. IT DOESN'T MATCH PLANS. |
| | |
| | B) ALL SIMPSON STRUCTURAL CONNECTORS SPECIFIED ON PLANS |
| | AND DETAILS. NOTE: PROVIDE ONLY THE FLORIDA PRODUCT |
| | APPROVAL COVER PAGE AND PAGE SHOWING THE SPECIFIED |
| | CONNECTOR OR ENGINEER OF RECORD TO LIST THE CURRENT |
| | FLORIDA PRODUCT APPROVAL NUMBER NEXT TO EACH SPECIFIED |
| | CONNECTOR. |
| | |
| | 8- ENGINEER OF RECORD TO APPROVE ABOVE PRODUCT |
| | APPROVALS BEFORE SUBMITTAL. SEC. 107.3.4.1 CITY |
| | AMENDMENTS. |
| | |
| | 9- CLEARLY SPECIFY SIZE OF MULLIONS TO BE USED TO |
| | VERIFY COMPLIANCE WITH THE DESIGN PRESSURES OF SEC. |
| | R301.1 FBC-RESIDENTIAL. |
| | |
| | 10- SPRAY INSULATION ICC EVALUATION REPORT ESL-1060 |
| | SUBMITTED: |
| | A) PROVIDE CURRENT REPORT. THE ONE SUBMITTED EXPIRED ON |
| | 03/2017. SEC. 107.2.1 CITY AMENDMENTS. |
| | |
| | B) PLANS DON'T SHOW ANY SPRAY INSULATION. ENGINEER OF |
| | RECORD TO CLEARLY SPECIFY ON PLANS AND WALL |
| | SECTIONS/DETAILS INSULATION TYPE AND LOCATION. SEC. |
| | 107.2.1 CITY AMENDMENTS. |
| | |
| | C) ENGINEER OF RECORD TO REVIEW AND APPROVE INSULATION |
| | REPORT PRIOR TO SUBMITTAL. SEC. 107.3.4.1 CITY |
| | AMENDMENTS. |
| | |
| | PLEASE PROVIDE RESPONSE LETTER CLEARLY ADDRESSING EACH |
| | COMMENT TO EXPEDITE THE REVIEW PROCESS |
| | ****PLEASE INSERT ANY REVISED DRAWING AND REMOVE OLD |
| | DRAWING. DON'T STAPLE OLD DRAWINGS. SUBMIT OLD DRAWINGS |
| | FOR REFERENCE. |
| | |