2017-06-28 09:04:51****CORRECTIONS****
  
 SAMANTHA HILL
 BUILDING PLANS EXAMINER
 [email protected]
 561-805-6724
  
 FBC = FLORIDA BUILDING CODE, 5TH EDITION (2014)
  
 2ND REVIEW IS BASED ON INFORMATION PROVIDED VERBALLY BY
 APPLICANT
  
 1. OPEN MECHANICAL PERMIT, 17050350 STATES THAT THE
 DESIGN CRITERIA IS FOR AN OPEN BUILDING, APPROXIMATELY
 119' HIGH, 170MPH EXPOSURE C.
  
 IT APPEARS THAT THIS PROJECT IS APPROXIMATELY 20' HIGH,
 EITHER PARTIALLY ENCLOSED OR ENCLOSED.
 SEOR (JOE MINCUZZI, PE, ONM&J) DID NOT SPECIFY
 COMPONENT AND CLADDING PRESSURES.
  
 SEOR IS TO SPECIFY C&C PRESSURES FOR THIS PROJECT, FBC
 B 1609.
  
 2. THE VALUE OF PERMIT 17050350 APPEARS TOO LOW TO
 INCLUDE THIS PERMIT; PROVIDE A COPY OF THE CONTRACT FOR
 THIS JOB.
  
 3. SEOR IS TO REVIEW THE ROOFING SUBMITTAL PRIOR TO
 SUBMITTAL TO THE CITY, FBC 107.
  
 4. PROVIDE A LETTER FROM MECHANICAL CONTRACTOR (WHO IS
 ACTING AS PRIME CONTRACTOR ON THIS JOB) REQUESTING THAT
 THE OTHER OPEN ROOFING PERMIT (17051222) BE REVOKED,
 FBC 107. THIS MAY BE SENT DIRECTLY TO ME VIA EMAIL. THE
 LETTER IS TO BE ON LETTERHEAD, SIGNED BY THE QUALIFIER.
  
 5. A BUILDING PERMIT OR A REVISION IS REQUIRED. THE
 PLAN SPECIFIES STRUCTURAL WORK INCLUDING STRUCTURAL
 REPAIR; THIS IS NOT WITHIN THE SCOPE OF A MECHANICAL OR
 A ROOFING CONTRACTOR LICENSE. THE REQUESTED ROOF WORK
 CANNOT BE DONE UNTIL THE STRUCTURAL WORK IS INSPECTED.
  
  