2017-06-14 16:52:561ST REVIEW: FBC 2014 5TH ED.
 1ST REVIEW FBC 2014 EXISTING BUILDING
  
 PLEASE SUPPLY MORE DETAIL AS TO THE SQUARE FOOTAGE OF
 THE INSTALLATION EITHER BY FLOOR PLAN OR A PROPOSAL TO
 DEMONSTRATE THE SIZE AND VALUE OF THE INSSTALLATION.
 NOTE THE PERMIT FEE IS BASED UPON HE FULL MARKET VALUE
 OF THE FLOOR SYSTEM INCLUDING THE TILE. IT APPEARS THIS
 IS FOR A BEDROOM. MOST BEDROOMS ARE A MINIMUM OF 100
 SQUARE FEET, SO AT A $10.00/SF RATE, YOUR VALUE APPEARS
 FINE BUT NONETHELESS, PLEASE PROVIDE THE INFORMATION.
  
 TWO COPIES OF TEST REPORTS FOR THE UNDERLAYMENT IS
 REQUIRED TO BE SUBMITTED TO DEMONSTRATE COMPLIANCE WITH
 THE SECTIONS BELOW IN THE INSTALLED CONDITION. I WILL
 EMAIL TO YOU AN EXAMPLE OF A TYPICAL SUBMITTAL.
  
 FBC 603.1 FLAME SPREAD
  
 FBC 1207.2 AIR-BORNE SOUND.
 WALLS, PARTITIONS AND FLOOR/CEILING ASSEMBLIES
 SEPARATING DWELLING UNITS FROM EACH OTHER OR FROM
 PUBLIC OR SERVICE AREAS SHALL HAVE A SOUND TRANSMISSION
 CLASS (STC) OF NOT LESS THAN 50 (45 IF FIELD TESTED)
 FOR AIR-BORNE NOISE WHEN TESTED IN ACCORDANCE WITH ASTM
 E 90.
  
 1207.3 STRUCTURE-BORNE SOUND.
 FLOOR/CEILING ASSEMBLIES BETWEEN DWELLING UNITS OR
 BETWEEN A DWELLING UNIT AND A PUBLIC OR SERVICE AREA
 WITHIN THE STRUCTURE SHALL HAVE AN IMPACT INSULATION
 CLASS (IIC) RATING OF NOT LESS THAN 50 (45 IF FIELD
 TESTED) WHEN TESTED IN ACCORDANCE WITH ASTM E 492.
  
  