| Date |
Text |
| 2017-06-19 08:16:46 | 2014 FBC- BUILDING PLAN REVIEW |
| | W. P. B. PERMIT: 17060316 |
| | ADD: 1401 FORUM WAY, SUITE: 300 |
| | CONT: MILLER CONSTRUCTION |
| | TEL: 954-847-0619 |
| | E-MAIL: [email protected] |
| | |
| | 2014 FLORIDA BUILDING CODE W 2014 WEST PALM BEACH |
| | AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1, |
| | ADMINISTRATION |
| | |
| | 2014 EXISTING BUILDING CODE LEVEL II 701.3 COMPLIANCE. |
| | ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND |
| | SPACES SHALL COMPLY WITH THE REQUIREMENTS OF THE |
| | FLORIDA BUILDING CODE, BUILDING. |
| | |
| | 1ST REVIEW |
| | DATE: MON. JUNE19/ 2017 |
| | ACTION: DENIED |
| | |
| | 1) PLEASE NOTE THE COVERSHEET AND ALL ARCHITECTURAL |
| | SHEETS HAVE DIGITAL/ PIXILATED SIGNATURES, NOT AN |
| | ORIGINAL INK SIGNATURE. FL ADMIN CODE 61G16.003 |
| | ARCHITECTS. |
| | |
| | 2) THE COVERSHEET REFERENCED CODES, GENERAL NOTES LIST |
| | THE AUTHORITY HAVING JURISDICTION AS: WESTON, FL. |
| | PLEASE CORRECT, THE MUNICIPALITY HAVING JURISDICTION IS |
| | THE CITY OF WEST PALM BEACH, FL. PLEASE UPDATE PLANS. |
| | 107.2.1.3 ADDITIONAL INFORMATION REQUIRED. |
| | |
| | 3) SHEET MD100 SHOWS A/C DUCTS PENETRATING A 2 HR. FIRE |
| | RATED VERTICAL EXIT STAIRWAY WITH NO FIRE RATING. |
| | PLEASE SHOW COMPLIANCE WITH 2014 FBC-B SECTION 1022.5 |
| | PENETRATIONS. PENETRATIONS INTO AND OPENINGS THROUGH |
| | INTERIOR EXIT STAIRWAYS AND RAMPS ARE PROHIBITED EXCEPT |
| | FOR REQUIRED EXIT DOORS, EQUIPMENT AND DUCTWORK |
| | NECESSARY FOR INDEPENDENT VENTILATION OR |
| | PRESSURIZATION, SPRINKLER PIPING, STANDPIPES, |
| | ELECTRICAL RACEWAY FOR FIRE DEPARTMENT COMMUNICATION |
| | SYSTEMS AND ELECTRICAL RACEWAY SERVING THE INTERIOR |
| | EXIT STAIRWAY AND RAMP AND TERMINATING AT A STEEL BOX |
| | NOT EXCEEDING 16 SQUARE INCHES (0.010 M2). SUCH |
| | PENETRATIONS SHALL BE PROTECTED IN ACCORDANCE WITH |
| | SECTION 714. THERE SHALL BE NO PENETRATIONS OR |
| | COMMUNICATING OPENINGS, WHETHER PROTECTED OR NOT, |
| | BETWEEN ADJACENT INTERIOR EXIT STAIRWAYS. |
| | |
| | 4) WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION |
| | & REMOVE ANY VOIDED SHEETS & REPLACE ANY PAGES AS |
| | NECESSARY, COLLATE AND STAPLE INTO SETS OF PLANS. A |
| | TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW COMMENT |
| | NUMBER, WITH A DESCRIPTION OF THE REVISION MADE, |
| | IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE THE |
| | CHANGES CAN BE FOUND WILL HELP TO EXPEDITE YOUR PERMIT. |
| | THANK YOU FOR YOUR ANTICIPATED COOPERATION. |
| | |
| | JAMES A. WITMER BN, PX, CBO |
| | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER |
| | CONSTRUCTION SERVICES DIVISION / DEVELOPMENT SERVICES |
| | DEPARTMENT |
| | 401 CLEMATIS ST. |
| | WEST PALM BEACH. FL 33402 |
| | TEL: 561-805-6715 |
| | FAX: 561-805-6676 |
| | |