2017-09-06 16:15:571ST REVIEW: FBC 2014 5TH EDITION
  
 PLUMBING COMMENTS:
  
 PREVIOUS COMMENT HAS NOT COMPLIED 3. TOILET PAPER
 DISPERSER SHALL COMPLY WITH FBC ACC 604.7 DISPENSERS.
 TOILET PAPER DISPENSERS SHALL COMPLY WITH 309.4 AND
 SHALL BE 7 INCHES (180 MM) MINIMUM AND 9 INCHES (230
 MM) MAXIMUM IN FRONT OF THE WATER CLOSET MEASURED TO
 THE CENTERLINE OF THE DISPENSER. THE OUTLET OF THE
 DISPENSER SHALL BE 15 INCHES (380 MM) MINIMUM AND 48
 INCHES (1220 MM) MAXIMUM ABOVE THE FINISH FLOOR AND
 SHALL NOT BE LOCATED BEHIND GRAB BARS. DISPENSERS SHALL
 NOT BE OF A TYPE THAT CONTROLS DELIVERY OR THAT DOES
 NOT ALLOW CONTINUOUS PAPER FLOW.
  
 NEW COMMENTS:
  
 1. THE WATER FOUNTAIN IS REQUIRED TO COMPLY WITH FBC
 ACC 307 PROTRUDING OBJECTS
  
 2. GRAB BARS SHALL BE MEASURED FROM FINISH FLOOR TO THE
 TOP OF THE GRIPPING SURFACE, PER FBC ACC 609.4
  
 3.SHOW CLEAR FLOOR SPACE FOR SINK IN COFFEE ROOM. PER
 FBC ACC 606.2
  
 4. SHT. A-3.1 SHOWS TOTAL ROOF SQFT OF 1526FT SHT. P-3
 SHOWS 1470SQFT PLEASE CLARIFY. PER WPB AMEND TO FBC
 107.2
  
 PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS.
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT
 CORRECTED PAGES INTO TO SUBMITTAL AND REMOVE OR VOID
 THE PREVIOUSLY REVIEWED SHEETS.
  