| 2017-07-05 15:02:48 | ****CORRECTIONS**** |
| | |
| | SAMANTHA HILL |
| | BUILDING PLANS EXAMINER |
| | [email protected] |
| | 561-805-6724 |
| | |
| | FBC = FLORIDA BUILDING CODE, 5TH EDITION (2014) |
| | FBC B = FBC BUILDING |
| | FBC EB = FBC EXISTING BUILDING |
| | FBC A = FBC ACCESSIBILITY |
| | FBC EC = FBC ENERGY CONSERVATION |
| | |
| | 17060191 3 STORY APARTMENT BUILDING |
| | 17060189 6 STORY APARTMENT BUILDING |
| | 17060192 CLUBHOUSE (BLDG F) |
| | |
| | 1. ALL PAGES HAVE AN INCORRECT ADDRESS AND NOT ALL ARE |
| | CONSISTENT WITH EACH OTHER (DIFFERENT INCORRECT |
| | ADDRESSES). FBC 107, PLEASE CORRECT THE ADDRESS ON EACH |
| | PAGE. |
| | |
| | 2. FS471.0195, THE DBPR RECORD FOR THE FOLLOWING |
| | ENGINEER(S) DO NOT REFLECT THAT THE ADVANCED FLORIDA |
| | BUILDING CODE COURSE HAS BEEN COMPLETED. EMAIL THE |
| | CERTIFICATE TO FBPE AND REQUEST THAT THE DBPR RECORD BE |
| | UPDATED. NOTE THAT IT IS POSSIBLE THAT THE COURSE WAS |
| | COMPLETED AND THE WEBSITE IS NOT CURRENT. |
| | |
| | SANTIAGO ARANEGUI, PE |
| | JOE SPASOVSKI, PE |
| | |
| | PERMIT ISSUANCE WILL NOT BE DELAYED DUE TO THIS |
| | COMMENT. HOWEVER, FLORIDA STATUTE REQUIRES THAT: |
| | LOCAL JURISDICTIONS SHALL BE RESPONSIBLE FOR NOTIFYING |
| | THE BOARD WHEN DESIGN DOCUMENTS ARE SUBMITTED FOR |
| | BUILDING CONSTRUCTION PERMITS BY PERSONS WHO ARE NOT IN |
| | COMPLIANCE WITH THIS SECTION. |
| | |
| | 3. SHEET LS DECLARES A3 OCCUPANCY, OFFICE SHOULD BE |
| | BUSINESS, PLEASE REVISE. |
| | |
| | 4. S1.0, DESIGN PRESSURES DO NOT STATE ULTIMATE OR ASD |
| | FOR COMPONENT AND CLADDING PRESSURES, FBC 107. WIND |
| | DESIGN CRITERIA SHOULD INCLUDE BOTH (SEE FBC B |
| | 1603.1.4), ONLY ASD WIND SPEED WAS INCLUDED, C&C |
| | PRESSURES APPEAR TO BE ASD BUT NOT STATED AS SUCH, |
| | PLEASE CLARIFY. |
| | |
| | 5. S1.0, ROOF LIVE LOAD IS 20PSF; FBC B TABLE 1607.1 |
| | REQUIRES 300 CONCENTRATED FOR "ALL ROOF SURFACES |
| | SUBJECT TO MAINTENANCE WORKERS". RTU EQUIPMENT SHOWN. |
| | EITHER REVISE DESIGN CRITERIA FOR THIS ROOF SECTION OR |
| | PROVIDE RATIONALE FOR 20PSF LIVE LOAD. |
| | |
| | 6. IT APPEARS THAT NOT ALL LAP SPLICES WERE SPECIFIED |
| | ON THE PLAN FOR THE FOUNDATION; REVISE PLAN OR ADVISE |
| | WHERE THIS CAN BE LOCATED, FBC 107, FBC B CHAPTER 19. |
| | |
| | 7. AS THIS IS NEW CONSTRUCTION, APPLY FOR AN |
| | ENGINEERING PERMIT; 561-494-1040. ENGINEERING |
| | DEPARTMENT APPROVAL IS REQUIRED PRIOR TO PERMIT |
| | ISSUANCE. CONTACT THEM DIRECTLY REGARDING REQUIREMENTS. |
| | IF YOU HAVE ALREADY APPLIED, PROVIDE THE APPLICATION |
| | NUMBER. I WAS UNABLE TO LOCATE AN ENGINEERING |
| | APPLICATION FOR THIS PARCEL ID. |
| | |
| | HTTP://WPB.ORG/DEPARTMENTS/ENGINEERING-PUBLIC-WORKS/FOR |
| | MS,-PERMITS-APPLICATIONS |
| | |
| | 8. A SEPARATE ROOF PERMIT IS REQUIRED. NO ROOF COVERING |
| | PRODUCT APPROVAL WAS SUBMITTED. THIS MAY BE SUBMITTED |
| | AT TIME OF ROOF PERMIT APPLICATION. |
| | |
| | FBC 1609, AT THIS TIME, APPLICANT MAY INDICATE WHICH |
| | APPROVED ASSEMBLY IS PROPOSED. IF THIS IS DONE NOW |
| | (ROOF PRODUCT APPROVAL SUBMITTED AND ASSEMBLY |
| | SELECTED), THE ROOF SUB PERMIT WILL BE ISSUED AT TIME |
| | OF SUB PERMIT APPLICATION WITHOUT ADDITIONAL |
| | INFORMATION REQUIRED. |
| | |
| | IF APPLICANT DOES NOT PROVIDE THIS INFORMATION AT THIS |
| | TIME, THIS PERMIT WILL BE ISSUED WITH PROVISO THAT, AT |
| | TIME OF ROOF SUB PERMIT APPLICATION, A PRODUCT APPROVAL |
| | REVIEWED BY DESIGNER OF RECORD IS TO BE SUBMITTED AND |
| | THE APPROVED ASSEMBLY IS TO BE SELECTED. A PLAN REVIEW |
| | WILL BE REQUIRED AT THAT TIME. |
| | |
| | ********************************************** |
| | INTERNAL USE ONLY |
| | |
| | 17060192 BUILDING DATA FOR C.O./REPORTING |
| | |
| | USC-404 318 ... - NEW: ATHLETIC/SOCIAL CLUBS |
| | SQUARE FEET - 5090 |
| | |
| | CONSTRUCTION TYPE: 14-III-B - 5TH ED TYPE III-B |
| | UNITS: 1 |
| | FLOORS: 2 |
| | BEDROOMS: |
| | ROOMS: |
| | SQ FT LIVABLE: 5090 |
| | SQ FT FOOTPRINT: 3330 |
| | SQ FT ROOF: 5090 |
| | |
| | SETBACKS FRONT (USE THIS TO ENTER VERTICAL DATUM IF |
| | KNOWN): |
| | SETBACKS BACK (USE THIS TO ENTER FIRST FLOOR IF KNOWN): |
| | XX.XX |
| | SETBACKS LEFT (USE THIS TO ENTER SECOND FLOOR IF KNOWN: |
| | XX.XX |
| | OCC LOAD: 98 |
| | PROP USE: CLUB/PRKG |
| | SPRINKLER SYS? N |
| | SPRK REQ'D? N |
| | BATHRMS: |
| | |
| | BLDG CODE: FL 2014 |
| | OCC CLASS: 5TH ED A2 |
| | |
| | |