| 2017-09-30 10:33:57 | 2014 FBC- BUILDING PLAN REVIEW |
| | W. P. B. PERMIT: 17060134 |
| | ADD: 900 N. OLIVE AVE. |
| | CONT: TBD/ TO BE DETERMINED |
| | TEL: 561-801-5058 |
| | E-MAIL: [email protected] |
| | |
| | 2014 FLORIDA BUILDING CODE W 2014 WEST PALM BEACH |
| | AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1, |
| | ADMINISTRATION |
| | |
| | 2014 EXISTING BUILDING CODE LEVEL II 701.3 COMPLIANCE. |
| | ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND |
| | SPACES SHALL COMPLY WITH THE REQUIREMENTS OF THE |
| | FLORIDA BUILDING CODE, BUILDING. |
| | |
| | 2ND REVIEW |
| | DATE: SAT. SEPT. 30/ 2017 |
| | ACTION: DENIED |
| | |
| | NO NARRATIVE SUBMITTED WHERE THE CHANGES TO THE PLAN |
| | WERE MADE!!!!!!! |
| | |
| | 1) THE LIFE SAFETY PLAN: |
| | 1A-B) NEW PLAN CONCEPT, NO VERTICAL ADDITION. |
| | DISCREPANCY IN PERMIT APPLICATION AND PLANS. THE PERMIT |
| | APPLICATION STILL INDICATES UNDER THE SCOPE OF WORK AN |
| | ADDITION. SHEET L-1 INDICATES A PROPOSED 2 STORY |
| | BUILDING. DISCREPANCY IN THE PLANS AND PERMIT |
| | APPLICATION. 107.2.1.3. ADDITIONAL INFORMATION |
| | REQUIRED. CORRECT BOTH THE SCOPE OF WORK ON THE PERMIT |
| | APPLICATION AND THE PLANS. |
| | 1ST ROUND COMMENTS. 1A) LIST THE 2014 FLORIDA BUILDING |
| | CODE, EXISTING BUILDING CODE PLEASE ADD THE CHAPTER 11 |
| | FOR ADDITIONS. |
| | |
| | 1ST ROUND OF COMMENTS. 1B) IN THE 2014 FBC-EXISTING |
| | BUILDING CODE SECTION 1103.3.1 DEALS WITH VERTICAL |
| | ADDITIONS, PLEASE PROVIDE THAT THE EXISTING BUILDING |
| | WILL MEET THE WIND PROVISIONS OF THE FLORIDA BUILDING |
| | CODE BUILDING IN SECTION 1609. PLEASE PROVIDE |
| | DOCUMENTATION THAT THE VERTICAL ADDITION WILL NOT |
| | CREATE A NONCONFORMITY TO THE FOUNDATION, THAT IT WILL |
| | ACCEPT THE ADDITIONAL LOADING OF THE 2ND STORY |
| | ADDITION. 2014 EXISTING BUILDING CODE 1101.2 CREATION |
| | OR EXTENSION OF NONCONFORMITY. |
| | |
| | 1C) COMPLIED. CONSTRUCTION TYPE: IIIB. |
| | |
| | 1D-F) COMPLIED/ NEW DESIGN. |
| | |
| | 1G) NEW DESIGN, NEW COMMENT PLEASE BE ADVISED AT BOTH |
| | ENTRY/ EGRESS DOORS THE EXTERIOR WALL TO INTERIOR |
| | FINISH WALLS SCALE OUT TO BE OVER 1?-0? THICK. PLEASE |
| | SHOW COMPLIANCE WITH THE 2014 FBC-ACCESSIBILITY CODE |
| | 404.2.4.3 AND FIGURE 404.2.4.3( C ). 404.2.4.3 RECESSED |
| | DOORS AND GATES. |
| | MANEUVERING CLEARANCES FOR FORWARD APPROACH SHALL BE |
| | PROVIDED WHEN ANY OBSTRUCTION WITHIN 18 INCHES OF THE |
| | LATCH SIDE OF A DOORWAY PROJECTS MORE THAN 8 INCHES |
| | BEYOND THE FACE OF THE DOOR, MEASURED PERPENDICULAR TO |
| | THE FACE OF THE DOOR. |
| | |
| | 2-6) COMPLIED/ NEW PLAN, NOT REQUIRED. |
| | |
| | 6A) NEW COMMENT: SHEET A1.1 DOOR TYPE A, C AND |
| | SIDELIGHT FOR DOOR TYPE B. NONE OF THESE DOORS OR |
| | SIDELIGHTS INDICATE THEY REQUIRE SAFETY GLAZING. SEE |
| | 2014 FBC-B 2406.4.1 & 2406.4.2. |
| | |
| | 7-10) COMPLIED/ NEW PLAN DESIGN. |
| | |
| | 11) SHEET S.1: |
| | 11A) 2ND REQUEST. STRUCTURAL NOTES DESIGN CRITERIA: |
| | RESIDENTIAL PLEASE UPDATE THE PLAN TO THE 2014 FLORIDA |
| | BUILDING CODE EXISTING BUILDING & FLORIDA BUILDING |
| | CODE-BUILDING. |
| | |
| | 11B-13) COMPLIED/ NEW DESIGN. |
| | |
| | 14) COMPLIED NEW DESIGN NO INCREASE IN FOOT PRINT OF |
| | BUILDING. |
| | |
| | 15) WHEN RESUBMITTING PLANS PLEASE INDICATE THE |
| | REVISION & REMOVE ANY VOIDED SHEETS & REPLACE ANY PAGES |
| | AS NECESSARY, COLLATE AND STAPLE INTO SETS OF PLANS. A |
| | TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW COMMENT |
| | NUMBER, WITH A DESCRIPTION OF THE REVISION MADE, |
| | IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE THE |
| | CHANGES CAN BE FOUND WILL HELP TO EXPEDITE YOUR PERMIT. |
| | THANK YOU FOR YOUR ANTICIPATED COOPERATION. |
| | |
| | THIS REVIEW CYCLE A THOROUGH REVIEW COULD NOT BE |
| | COMPLETED AND ADDITIONAL AND OR NEW COMMENTS MAY OCCUR |
| | ON SUBSEQUENT REVIEWS. |
| | |
| | JAMES A. WITMER BN, PX, CBO |
| | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER |
| | CONSTRUCTION SERVICES DIVISION / DEVELOPMENT SERVICES |
| | DEPARTMENT |
| | 401 CLEMATIS ST. |
| | WEST PALM BEACH. FL 33402 |
| | |