| Date |
Text |
| 2017-06-06 07:57:01 | 1ST REVIEW FBC-2014 MECHANICAL |
| | PERMIT #17051281 |
| | 6/6/17 |
| | |
| | RESULTS: DENIED. |
| | |
| | 1) THE PLAN SHOWS 1900 CFMS OF SUPPLY AIR BEING |
| | PROVIDED BY AN EXISTING 2-TON UNIT WHICH FAR EXCEEDS |
| | THE UNIT'S CAPACITY- PLEASE CORRECT OR CLARIFY. PLEASE |
| | NOTE THERE IS A 4" DUCT DROP IN THE POWDER ROOM |
| | INDICATED AT 200 CFMS WHICH EXCEEDS THE CAPACITY OF A |
| | 4" DUCT- SEE THE DUCT SIZE PREVIEW WHICH INDICATES 10 |
| | CFMS FOR THE POWDER ROOM. |
| | |
| | 2) MISSING FROM THE DUCT SIZING PREVIEW ARE THE LAUNDRY |
| | ROOM, THE STORAGE ROOM, AND CAROLYN'S BED AND BATHROOM. |
| | |
| | 3) PROVIDE A COMPLETE DRYER EXHAUST PLAN THAT INCLUDES |
| | THE TOTAL LENGTH OF THE DRYER RUN FROM OUTLET TO DRYER |
| | TERMINATION LOCATION, CLARIFY IF THE NEW EXHAUST DUCT |
| | IS CONNECTING INTO AN EXISTING CHASE AND SHOW THE |
| | LOCATION AND HOW CONNECTION IS BEING MADE. PLEASE |
| | SUBMIT MANUFACTURER'S SPECIFICATIONS FOR THE DRYER- |
| | SECTION 504. |
| | |
| | 4) PROVIDE COMPLETE KITCHEN EXHAUST PLANS FOR THE NEW |
| | COOKING APPLIANCES. SHOW THE TYPES AND SIZES OF EXHAUST |
| | HOODS, EXHAUST DUCTS AND SUBMIT MANUFACTURER'S |
| | SPECIFICATIONS FOR THE APPLIANCES AND THE HOODS. SHOW |
| | THE EXHAUST DUCT RUNS FROM THE EXHAUST OUTLETS TO |
| | TERMINATION LOCATIONS. IF CONNECTING INTO A CHASE, |
| | INDICATE SHOW CONNECTION IS BEING MADE. PLEASE NOTE |
| | |
| | THAT SEPARATE CHASES ARE REQUIRED FOR KITCHEN EXHAUST, |
| | DRYER EXHAUST AND BATH EXHAUST- SECTION 501.2. |
| | |
| | CHRISTOPHER L. COLE |
| | MECHANICAL PLANS EXAMINER |
| | 401 CLEMATIS STREET |
| | WEST PALM BEACH FL 33401 |
| | 561-805-6719 |
| | [email protected] |
| | |